Text of UNI-T UT70A Operating Manual
TABLE OF CONTENTS
TITLE
PAGE
HIGHLIGHTS
NOTES FOR SAFE USAGE
FIGURATION AND ACCESSORIES
ELECTRIC SYMBOL
GENERAL INFORMATION
SPECIFICATIONS
1.DC Voltage (DCV)
2.AC Voltage (ACV)
3.DC Current (DCA)
4.AC Current (ACA)
5.Resistance
6.Capacitance
7. Inductance
8.Auto range frequency test
9.Transistor hFE measurement
10.Diode
11.Continuity Buzzer
12.TTL LOGIC Test
13.Temperatu
TABLE OF CONTENTS TITLE
PAGE
11. Transistor Parameter
Measurement (hFE)
12. Diode (or PN node of transistor)
Measurement( )
13. Continuity Buzzer Test
14. TTL LOGIC Test
MAINTENANCE
FUSE AND BATTERY replacement
Accessories
Model UT70A: OPERATING MANUAL
24
25
25
26
27
28
28
2
Operating Manual of UT70A Multimeter
HIGHLIGHTS
UT70A Multimeter is a hand-held digital multimeter with
advanced design, multiple functions, novel figuration,
large display screen and reliable performance. This meter
is fully capable to measure voltage and current both AC
and DC, resistance, capacitance, inductance, temperature,
frequency, forward voltage drop of diode, transistor hFE
and continuity test, TTL LOGIC level measurement. It
has some extraordin
5) Set the Range Selector to a proper position.
6) The measured value shall not exceed the maximum
range of each measurement to protect the meter from
damage and electric shock to user.
7) Range Selector shall not be switched during
measurement to avoid damage to the meter.
8) Cautions shall be taken to prevent electric shock
when the measured voltage is higher than 60V in
DC or 42Vrms in AC.
9) Identical fuse shall
UNI-T UT70A Model UT70A: OPERATING MANUAL
1. Front case
2. Functional buttons
3. Function/Range selector
4. Input terminal
5. LCD window
FIGURATION AND ACCESSORIES
1) The Meter Structure(see figure1)
5
2) Input Terminal of UT70A
Input
Terminal Description For short
10A Input terminal for current
0.2A-10A.
"A" Terminal
"mA"Terminal
Input terminal for voltage,
resistance, frequency,
diode, continuity, TTL LOGIC.
"V/ "
Terminal
COM
Common terminal for current,
voltage, resistance, frequency,
diode, continuity,
TTL LOGIC measurement.
"COM"Terminal
3)Accessories
1 Multi-purpose socket: used for measurement