Berkeley Varitronics Systems YellowFrog-Pro Operation & User’s Manual

Text of the manual

Table of Contents

Unboxing & Setup……….……………………………………………………... 2 Main Measurement (portrait view)…..…..………………………………….... 4 Main Measurement (landscape view)…..…..…..………………………….... 6 Frequency Input…………………………...…..…..………………………….... 7 Main Options……………………………….…..…..………………………….... 8 Unit Information……..…………………….…..…..………………………….... 9 PC Controller Software……..…………….…..…..………………………….... 10 dBm to Watts Conversion Table………….…..…..………………………….... 12

Unboxing & Setup

Remove the rugged Pelican 1200 travel case from packaging. Be sure to keep all shipping materials in case your YellowFrog-Pro unit requires shipping back to BVS for repair or calibration. The case includes the YellowFrog-Pro wide band power meter unit itself, DC power transformer, USB-A to USB-mini cable, USB stick containing PC controller software and this user manual, calibration certificate and Type ‘N’ to Type ‘N’ barrel plug adapter. We recommend turning the power switch OFF while charging. Before operating your unit, be sure to plug in the included power adapter to fully charge the unit. The red LED will turn on indicating charging in process. The red LED will turn off when the unit is fully charged. NOTE: If the red LED is flashing, it indicates the unit temperature is too hot to charge internal battery. Turn off the unit and let it cool down before attempting to charge. Turn on the unit’s power using the On/OFF switch.

Remove the screen protector one you are ready to use the unit. You may want to keep

the screen protector handy for working on sites where dirt and debris can easily scratch the touchscreen. Connect the USB-A to USB-mini cable from your unit to a PC running the included YellowFrog-Pro Controller software. Connect the supplied barrel plug to adapt to your required power output connection. FROM POWER SOURCE TO ANTENNA

Main Measurement (portrait view)

Upon powering up YellowFrog-Pro, you will see this main measurement screen. From here you can monitor power measurements in real time and navigate to all of the other screens Touch HOLD MAX button to display the maximum power measured Touch this button to flip the display from portrait to landscape view and back again. This feature is convenient for connection to stiff power cables that do not let users easily manage the unit from the desired viewing angle. Touch this MENU OPTIONS button to navigate to that screen to adjust settings This battery indicator shows remaining power in the unit. Runtime on a full charge is approximately 3 hours. Charging from a depleted battery takes less than 2 hours.

Power can be displayed in dBm or Watts. This can be

toggled on or off in the Main Options menu. TDD should only be shown when you want to measure a TDD (Time Division Duplex). This is a mode used in TDD LTE and future 56 bands. It can be toggled on or off in the Main Options menu. This indicates the number of forward samples averaged over 100 measurements. This horizontal scale represents the power measured from -20 dBm through +53 dBm. Touch this button to change the input frequency measured. You will be taken to a numeric keypad screen where you enter in any frequency between 500 MHz and 4000 MHz with accuracy of 5 places to the right of the decimal. This indicates the reflected power in dBm. This indicates the VSWR (Voltage Standing Wave Ratio)

Main Measurement (landscape view)

This main measurement screen is in landscape view but is functionally identical to the previous screen shown in portrait view. You may flip back and forth to each of these screens at any time by touching the orientation button at the top.

Use this screen to enter in any custom frequency between 500 MHz

and 4000 MHz. Arrow keys allow the users to adjust single digits of the frequency without the need to enter the entire frequency. Touch the ENTER button at any time to complete your entry and it will return you back to the Main Measurement screen.

Use this screen to change the output display to either dBm or

Watts. You may also adjust your average for forward power measurements using the up/down arrows and enter buttons You may also toggle TDD mode on or off (recommended to keep off) The CALIBRATE button is disabled and reserved to BVS support. Contact your BVS sales or support staff member if you have any questions. Touch the BACK arrow in the upper left corner of the screen to navigate back to the previous screen.

In this screen, you can see all the information about your unit at a

glance including the serial number (required for product support), firmware (updatable via USB), frequency range, step size, resolution bandwidth, minimum power input and maximum power input. Touch the BACK arrow in the upper left corner of the screen to navigate back to the previous screen.

PC Controller Software

You will find all the necessary Windows 10 PC software and drivers on the included USB stick with your unit. The YellowFrog-Pro PC controller software allows users to monitor measurements and control unit settings without having to physically access the unit. In addition to control over settings, this PC software also allows users to view power measurements as a graph of power measured over time. Once connected to the PC, turn on the unit to initiate control over it. This tab mirrors all unit parameters same as the Unit Information screen. This tab displays all measurements in power over time. The time duration is about 10 minutes.

This tab displays all measurements in power over time. The time duration is about 1 minute.

This tab displays current power measured in both dBm and Watts.

Thank you for your purchase, we look forward to supporting you and your team.

Customer Support Berkeley Varitronics Systems, Inc. Liberty Corporate Park 255 Liberty Street Metuchen, NJ 08840 8:00 AM to 6:00 PM EST Toll Free: 888-737-4287 Phone: 732-548-3737 Fax: 732-548-3404 24/7 (expect a reply within one day) email: [email protected] www.bvsystems.com

Other Measuring Instruments Manuals