6 Safety Information Description 9 Description 11 Control Panel Control Function 12 3 in 1 switch knob 12 Oil warning light (red) 13 Overload indicator light (red) 13 AC power indicator (green) 14 DC protector 14 Engine smart control (ESC) 15 Fuel tank cap 15 Ground (Earth) terminal Preparation 16 Fuel 16 Engine oil 17 Pre-operation check Operation 18 Operation 19 Staring the engine 20 Stopping the engine 21 Alternating Current (AC) connection 21 Battery Charging 23 Application range Maintenance 25 Maintenance 27 Spark plug inspection 28 Carburetor adjustment 28 Engine oil re ...
CAUTION, WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER you WILL be KILLED or SERIOUSLY HURT if you don’t follow instructions. WARNING you CAN be KILLED or SERIOUSLY HURT if you don’t follow instructions. CAUTION you CAN be HURT if you don’t follow instructions NOTICE your generator or other property could be damaged if you don’t follow instructions. Save these Instructions Safety Warnings This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid po ...
Read and understand this owner’s manual before operating your generator. It will help you avoid accidents if you are familiar with your generator’s safe operation procedures. WARNING Generator exhaust contains carbon monoxide, a poisonous gas that can kill you. You CANNOT smell or see this gas. • Use the generator outdoors, away from open windows, vents, or doors that could allow the carbon monoxide gas to come indoors. Keep the generator at least 1 meter (3 feet) away from any structure or building during use. • NEVER use a generator indoors, including in homes, garages, basements, crawl spaces, and other encl ...
Check with a qualified electrician for your local requirements if you are in doubt as to whether the unit is properly grounded. • This generator is equipped with a grounding terminal for added protection. Using the ground path from the generator to an external ground source as instructed in the section labeled “Grounding Instructions” in the Preparation section of this manual can be necessary. Please consult a qualified electrician for local regulations. • The generator is a potential source of electrical shock if not kept dry. Keep the generator dry and do not use in rain or we ...
DESCRIPTION 2 Con rt o l panel . 2 ② ③ ④ ⑤ ⑥ AC reset ⑦ DC receptacle USB AC Breaker ⑧ Ground (earth) terminal ⑨ DC protector ESC(Engine Smart Control) Switch knob AC receptacle Parallel function - 9 - Electric Recoil Oil warning light Overload indicator light AC pilot light DESCRIPTION 240V Multi functional digital meter Red Red Red Power display Inverter alert indicator. Light is off while this light is constantly on - 11 - 4 3 5 11 1 Fuel level indicator 6 2 Voltage-U000, Frequency-F00.0, Total working time-000.0(0.1h) , Working hours at one time-00.00 Switch the display b ...
4.1 3 in 1 switch knob 4.2 Oil warning light (red) When the oil level falls below the lower level, the oil warning light (1) comes on and then the engine stops automatically. Unless you refill with oil, the engine will not start again. TIP: If the engine stalls or does not start, turn the engine switch to “ON” and then pull the recoil starter. If the oil warning light flickers for a few seconds, the engine oil is insufficient. Add oil and restart. 4.3 Overload indicator light (red) The overload indicator light (1) comes on when an overload of a connected electrical device is detected, the inverter control unit overheats, o ...
The DC protector turns to “OFF” (2) automatically when electric device being connected to the generator is operating and current above the rated flows. To use this equipment again, turn on DC protector by pressing its button to “ON” (1) (1) “ON” Direct current is output. (2) “OFF” Direct current is not output. CAUTION • Reduce the load of the connected electric device below the specified rated output of the generator if the DC protector turns off. If the DC protector turns off again, stop using the device immediately and consult our company authorized dealer. 4.6 Engine smart control (ES ...
“SAFETY INFORMATION” carefully before filling. • Do not overfill the fuel tank, otherwise it may overflow when the fuel warms up and expands. • After filling, make sure the fuel tank cap is tightened securely. NOTICE • Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may deteriorate painted surfaces or plastic parts. • Use only unleaded gasoline. The use of leaded gasoline will cause severe damage to internal engine parts. Remove the fuel tank cap and fill the fuel into the tank up to the red level. (1) Red line (2) Fuel leve ...
unconsciousness and death within a short time. Operate the engine in a well ventilated area. • Before starting the engine, do not connect any electric devices. NOTICE • The generator has been shipped without engine oil. Do not start the engine till fill with the sufficient engine oil. • Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. TIP: The generator can be used with the rated output load at standard atmospheric conditions. “Standard atmospheric conditions” Ambient temperature 25° Barometric ...
TIP: Turn off any electric devices. 1. Turn the ESC to “OFF” (1). 2. Disconnect any electric devices. 3. Turn the 3 in 1 switch to “OFF” (2), a. Ignition circuit is switched off. b. Fuel is switched off. 6.3 Alternating Current (AC) connection WARNING • Be sure any electric devices are turned off before plugging them in. NOTICE • Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator. • Be sure the total load is within generator rated output. • Be sure the receptacle load current is within receptacle rated current. • The generat ...
• Be sure to connect the red battery charger lead to the positive (+) battery terminal ,and connect the black lead to the negative (-) battery terminal. Do not reverse these positions. • Connect the battery charger leads to the battery terminals securely so that they are not disconnected due to engine vibration or other disturbances. • Charge the battery in the correct procedure by following instructions in the owner’s manual for the battery. • The DC protector turns off automatically if current above the rated flows during battery charging. To restart charging the bat ...
exceed the supply range of the generator. Overloading will damage the generator. • When supplying precision equipment, electronic controllers, PCs, Electronic computers, microcomputer based equipment or battery chargers, keep the generator a sufficient distance away to prevent electrical interference from the engine. Also ensure that electrical noise from the engine does not interfere with any other electrical devices located near the generator. • If the generator is to supply medical equipment, advice should first be obtained from the manufacturer, a medical pro ...
heavy load, change the oil every 25 hours. • If the engine frequently work under dusty or other severe circumstances, clean the air filter element every 10 hours; If necessary, change the air filter element every 25 hours. • The maintenance period and the exact time (hour), the one which comes first should govern. • If you have missed the scheduled time to maintain your engine, do it as soon as possible. WARNING • Stop the engine before servicing. Put the engine on a level surface and remove the spark plug cap to prevent the engine from starting. • Do not ope ...
The carburetor is a vital part of the engine. Adjusting should be left to our company authorized dealer with the professional knowledge, specialized date, and equipment to do so properly. 7.3 Engine oil replacement WARNING • Avoid draining the engine oil immediately after stopping the engine. The oil is hot and should be handled with care to avoid burns. NOTICE • Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine. Recommended engine oil: SAE SJ 15W-40 Recommended engine oil grade: API Service SE type or higher Engine oil quantity: 0.5L NOTICE • Be sure no fo ...
excessive piston and cylinder wear may result. 7. Install the air filter case cover in its original position and tighten the screw. 8. Install the cover and tighten the screws. 7.6 Fuel tank filter WARNING • Never use the gasoline while smoking or in the vicinity of an open flame. 1. Remove the fuel tank cap and filter. 2. Clean the filter. 3. Wipe the filter dry and reinstall it. 4. Install the fuel tank cap. Be sure the fuel tank cap is tightened securely. 7.7 Fuel filter 1. Remove the screws (1), and then remove the cover (2), and drain the fuel. 2. Hold and move up the clamp (4), then t ...
procedures to guard against deterioration. 8.1 Drain the fuel 1. Turn the 3 in 1 switch to “OFF” (1) . 2. Remove the fuel tank cap, remove the filter . Extract the fuel from the fuel tank into an approved gasoline container. Then, install the fuel tank cap. WARNING • Fuel is highly flammable and poisonous. Check “SAFETY INFORMATION” (See page 6) carefully. NOTICE • Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may deteriorate painted surfaces or plastic parts. 3. Start the engine (See Page 19) and leave it running until it stops. ...
· Safety device (DC protector) to “OFF”…. Press the DC protector to “ON”. · The AC pilot light (Green) goes off …. Stop the engine, then restart. 10. SPECIFICATIONS 11. WIRING DIAGRAM SPECIFICATIONS WIRING DIAGRAM Model No. Type Rated frequency (Hz) Rated voltage (V) Rated output power (kW) Power factor AC output quality Charging Voltage (DC) (V) Charging Current (DC) (A) Overload Protect (DC) Generator Engine Generator set R3000is-2 R3000ie-2 Silent Inverter 240 2.8 1 ISO8528 G2 12 8.3 Non-fuse Protector Engine R210-i Oil Capacity (L) Spark Model No. Starting mode Length×Width×Height (mm) Net ...
or operation of your Generator please call 1-866-850-6662 Si vous avez besoin d’aide avec l’assemblage ou l’utilisation de votre génératrice, veuillez appeler au 1-866-850-6662 THE POWER YOU NEED. THE POWER YOU NEED. ...
· Dispositif de sécurité (protection CC) désactivé [OFF]… Appuyez sur le dispositif de protection CC pour l’activer [ON]. · La lampe-témoin CA (verte) s’éteint… Arrêtez le moteur, puis redémarrez-le. 10. SPÉCIFICATIONS 3500IP 3600IE Génératrice Inverseur Fréquence nominale (Hz) 50 Tension nominale (v) 240 La puissance nominale (W) 2.8 3.0 La tension nominale (W) 1 Facteur de puissance 1 La tension de charge (DC)(V) 12 Le courant de charge (DC)(A) 8,3 Protection contre les surcharges (DC) Protection sans fusible Étages Mono-étagé Motuer Moteur R210 Moteur Un seul cylindre, 4 ...
Portable Generator PDF Instructions
www.generac.com or 1-888-436-3722 Owner's Manual GP Series Portable Generator DEADLY EXHAUST FUMES! ONLY use OUTSIDE far away from windows, doors and vents! NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. SAVE this Manual. Provide thi Operating and setup manual for the Generac Power Systems GP Series Portable Generator. This guide provides technical guidance on specifications, error handling, warranty information, daily usage.
User reference manual for the Champion Power Equipment 73534i Portable Generator. This guide elaborates on device features and operational procedures, maintenance procedures, wiring setup, replacement parts.
Onon Installation Manual 10 GEAD 20 GEAE 25 GEAF GENERATOR SETS Printed U.S.A. 928-0606 6-94 Device technical manual for the CUMMINS Onan 10 GEAD Portable Generator. This guide presents instructions on connectivity setup, software installation, installation support, user instructions.
03/2009 SINUMERIK 840D sl/ 840Di sl/ SINAMICS S120 Diagnostics Manual Valid for Control SINUMERIK 840D sl/ 840DE sl SINUMERIK 840Di sl/ 840DiE sl Software NCU Systemsoftware für 840D sl/ 840DE sl 2.6 Systemsoftware für 840Di sl/ 840DiE sl 1.4 Dr Manual for safe operation of the Siemens SINUMERIK 840D sl Controller. The manual highlights troubleshooting, regulatory notices, system parameters, installation steps.