BEA G3 Quick Setup Manual
Text of BEA G3 Quick Setup Manual
IR Presence Sensing Field: Width and Depth (wide lens installed as default)
Dimensions Are Approximate Size
IR Patterns
Mounting Height of Sensor
7’
10’
12’
14’
Narrow Lens Depth of Two Curtains
1’3”
1’6”
1’8”
1’10”
Narrow Lens Width of Curtains
3’6”
5’
6’
7’
Wide Lens Depth of Two Curtains
1’3”
1’6”
1’8”
1’10”
Wide Lens Width of Curtains
6’6”
10’
12’
14’
1. The IR pattern may be adjusted by mo
Radar Motion Sensing Field: Width
6
Radar Motion Sensing Field: Depth
3.2’
6.4’
3.2’
6.4’
3.2’
6.4’
9.6’
3.2’
6.4’
3.2’
6.4’
0
3.2’
6.4’
9.6’
13.1’
Sensitivity
0 (min) → 9 (max) default = 7
0
3
6
9
0
3.2’
6.4’
3.2’
6.4’
0
3.2’
6.4’
9.6’
15°
30° 45°
30°
45°
15°
0°
Wide Pattern
Narrow Pattern
7
IR Presence Sensing Field / IR Assisted Setup
An Assisted Setup is Required after installation and any time aft