Becker E01 Assembly And Operating Instructions Manual

Specifications

Brand: Becker
Category: DC Drives
Model: E01 (Assembly And Operating Instructions Manual), prFjy3YxbtxRs
File Type: PDF
File Size: —
Pages: 32 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (32 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 28/07/2026).

Read Online

Read the Becker E01 Assembly And Operating Instructions Manual online using the built-in PDF viewer.

E01 Assembly And Operating Instructions Manual: Key Pages of Document

Assembly and Operating Instructions

Tubular drives for roller shutters Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com ...

Table of contents

General...............................................................................................................................................................................  3 Warranty .............................................................................................................................................................................  3 Safety instructions ...............................................................................................................................................................  4 Instructions for the user........................................................... ...

These tubular drives are high-quality products with the following features:

• Optimised for roller shutter operation • Installation without stops possible (from lower point to upper point) • Automatic detection of the lower limit position when using springs in conjunction with the "drive adapter for obstacle detec- tion" • Automatic detection of limit positions thanks to intelligent electronic system with stop systems • Obstacle detection, even when using anti-lifting devices (axle shaft devices) ∙ Secure anti-lifting device ∙ Slight pressure applied to the roller shutter curtain makes it difficult to raise or reach under it ∙ S ...

The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury.

Instructions for the user General information • All work, including maintenance and cleaning, on electrical installations as well as other system parts must always be performed by authorised specialists, in particular qualified electricians. • Children from the age of 8 years and persons with reduced physical, sensory or mental capabilities or lack of experience and/or knowledge may use these devices, provided they are supervised or have been instructed in the safe use of the device, and have understoo ...

• Moving parts of drives must be installed at a height of over 2.5 m above floor level or any other surface

from which access to the drive is gained. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in. • Drives with a H05VV-F connecting cable may only be used indoors. • Drives with a H05RR-F, S05RN-F or 05RN-F connecting cable may be used both indoors and outdoors. • To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. The components must be installed in accordance with ...

The type of tubular drive described in these instructions is intended solely for the operation of roller shutters.

This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti-lifting devices (e.g., Zurfluh-Feller, Simu, GAH Alberts and Deprat). These are detected automatically. If the springs or the top lath are not screwed or rivetted to the barrel, a point must be set in the lower limit position. For sunblinds, please use only the types of tubular drive designed for this purpose. This type of tubular drive is designed for use in single systems (one drive per barrel). The tubular drive must ...

Disassembling the plug-in connecting cable for tubular drives dia. 35.

Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. On drives with a diameter Ø35, insert a suitable flathead screwdriver between the locating lug and the snap-in pin, so that the snap-in pin releases the locating lug from the plug. Now you can pull out the connecting cable along with the flathead screwdriver. Ø35 A A = snap-in pin 7 ...

Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58

Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. On drives with a diameter Ø45 or Ø58, insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug. Now you can pull out the connecting cable along with the flathead screwdriver. dia. 45 and dia. 58 1. 2. A A = locating latch 8 ...

Assembling the drive

Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution). Caution Electrical connections may only be carried out by a qualified electrician. Prior to assembly, the power supply must be disconnected and secured. Please give the enclosed connection information to the responsible electrical contractor. Calculate the space required at the side (M) by ...

Assembling the drive adapter with screw connection

Put the drive adapter (1) onto the drive shaft of the tubular drive. For the assembly, use an M6 x 12 screw (3) with appropriate washer (2) and suitable screw retainer. Threaded hole (4) Securing the drive against axial displacement -10 mm In order to secure the drive against axial displacement, we recommend screwing the drive adapter to the tube. Attention When drilling into the barrel, never drill near the tubular drive! Fixing the drive adapter to the barrel dia. 35 and dia. 45 Size of drive [mm] Diameter of barrel [mm] Torque max. [Nm] Fastening screws for drive adapter (4 pc.) dia. 35 40 mm plasti ...

For round tubes:

First notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the tube. There must be no play between the lug of the thrust ring and the tube. Assemble the tubular drive with the relevant thrust ring (1) and drive adapter (2). In- sert the tubular drive with the pre-assembled thrust ring and drive adapter into the tube to achieve a form fit. Ensure that the thrust ring and drive adapter are secure in the tube. Mount the assembled unit comprising barrel, tubular drive and idler on the box and secure the drive with a split or spring pin ac- cording to the type of wall bracket fixing. Position the barrel so ...

Setting the limit positions with switches

Setting the limit positions There are 3 ways to set the limit positions: • Upper stop to lower stop • Upper point to lower point • Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times. If the tubular drive switches off prematurely while opening or closing, due to an obstruc- tion, the obstruction can be cleared by reversing a short way and removing the obstruc- tion. The desired limit position can be set by opening/closing again. Attention The switch is not suitable for continuous operation and has only been des ...

Upper point to lower point

There is no shading solution length adjustment with this limit position setting. Set both switches to the delete setting. Execute a short drive command. Open to the desired upper limit position. Now reset the switch of the UP direction of rotation from the delete setting to the pro- gramming setting. Then close to the desired lower limit position. Reset the switch of the DOWN direction of rotation from the delete setting to the pro- gramming setting. ► The limit positions are now set. Upper point to lower stop There is no shading solution length adjustment with this limit position setting. Set both switches to the delete se ...

Deleting the limit positions using the switches

Deleting individual limit positions It is possible to delete an individual limit position, if lower point to upper point without stops has been programmed with the switches. Reset the switch of the corresponding limit position from the programming setting to the delete setting. Execute a short drive command. ► The limit position is now deleted. Deleting both limit positions Reset both switches from the programming setting to the delete setting. Execute a short drive command. ► Both limit positions are deleted. 14 ...

Setting the limit positions using the programming unit

Setting the limit positions There are 4 ways to set the limit positions: • Upper stop to lower stop • Upper point to lower point • Upper stop to lower point • Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times. If the tubular drive switches off prematurely while opening or closing, due to an obstruc- tion, the obstruction can be cleared by reversing a short way and removing the obstruc- tion. The desired limit position can be set by opening/closing again. Attention The switch is not suitable for ...

Lower point to upper point without stops

There is no shading solution length adjustment with this limit position setting. Set both switches to the programming setting. Open to the desired upper limit position. Press the programming button of the programming unit for 3 seconds. ▻ The tubular drive makes a “click” sound to confirm. Then close to the desired lower limit position. Press the programming button of the programming unit for 3 seconds. ▻ The tubular drive makes a “click” sound to confirm. ► The limit positions are now set. Upper stop to lower point Set both switches to the programming setting. Open as far as the permanent upper st ...

Upper point to lower stop

Set both switches to the programming setting. Open to the desired upper limit position. Press the programming button of the programming unit for 3 seconds. ▻ The tubular drive makes a "click" sound to confirm. Then move down to the lower limit position. ▻ The tubular drive switches off automatically. ► The limit positions are now set. 17 ...

Deleting the limit positions using the programming unit

Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence. Also leave a pause of 1 sec between the individual steps of the deletion sequence. Deleting a limit position when 2 limit positions are programmed black brown blue green-yellow black brown blue green-yellow Programming button Travel button Open/close to the limit position to be deleted. Press the programming button and keep it pressed. Then press down the travel button and keep it pre ...

Deleting both limit positions

Open/close the shading solution to a point between the limit positions. Press the programming button and keep it pressed. Then press down the travel button and keep it pressed. Now release the programming button, but continue to keep the travel button pressed. Next press the programming button again. ▻ The tubular drive makes a "click click" sound to confirm. ► Both limit positions are deleted. Adjusting the limit positions with a rotary switch or a locking button Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that dir ...

Upper stop to lower stop

Open to the permanent upper stop. ▻ The tubular drive switches off automatically. Then close to the permanent lower stop without pausing. During travel, the end posi- tion status indicator (ESI) must be displayed before the end position is reached. ▻ The tubular drive switches off automatically. ► The limit positions are now set. Upper point to lower point There is no shading solution length adjustment with this limit position setting. Open to the desired upper limit position. Carry out the following sequence without interruption between the individual drive commands. ▻ The tubular drive makes a "click" sound to confirm ...

DC Drives PDF Instructions

390S.B
Rowan Elettronica 390S.B
03.07.2026 24 pages

INSTRUCTION MANUAL Cod.390S.B UNIDIRECTIONAL DRIVE FOR ROWAN THREEPHASE HIGH SLIP MOTORS EMC CONFORMITY Motori, azionamenti, accessori e servizi per l'automazione Via Ugo Foscolo, 20 - CALDOGNO - VICENZA - ITALIA Tel.: 0039 0444 - 905566 (4 linee r.a.) Fax: 00 Step-by-step user manual for the Rowan Elettronica 390S.B DC Drives. The document presents system setup, maintenance guidelines, troubleshooting guides.

VLT OneGearDrive
Danfoss VLT OneGearDrive
20.06.2026 21 pages

MAKING MODERN LIVING POSSIBLE Installation Instructions VLT� OneGearDrive Installationsanweisungen • Instrucciones de instalación • Instruções de instalação • Installatie-instructies • Инструкции по монтажу • ���� v Instruction manual for the Danfoss VLT OneGearDrive Engine. It provides information on installation and maintenance procedures, operational guidelines, regulatory notices.

PXC00-PE96.A
Siemens PXC00-PE96.A
02.04.2026 2 pages

Installation Instructions Document No. 565-719 July 22, 2016 Andover Infinet Driver for PXC Modular Item Number 565-719, Rev. BA Page 1 of 2 These installation instructions only cover the connection of the Andover Infinet Driver to the Andover Infinet network Instruction reference guide for the Siemens PXC00-PE96.A DC Drives. It covers topics such as installation procedures, device overview, internal layout.

bt300
Siemens bt300
10.07.2026 4 pages

Installation Instructions Document No. DPD01160D December 4, 2019 BT300 HVAC Drives Main Switch Page 1 of 4 Product Description The main switch is used for switching off the input power of the drive. This option is available for frames FS4-FS7 with Type 12/IP5 Installation instructions for the Siemens bt300 Switch. It provides instructions for operational guidelines, system setup, compatibility information.