Text of Ei Electronics EIB140RC Series Instruction Manual

© Brooks 2018

P/N B18866Rev1 230V~ SMOKE & HEAT ALARMS EIB140RC Series Instruction Manual with Alkaline Battery Backup The EIB140RC series is supplied with an Easi-Fit base that allows very quick and simple installation of the Smoke Alarm, combined with simple detector head removal and replacement. The Easi-Fit base automatically connects both mains power and battery as the detector head slides on to the Easi-Fit base. Up to 12 Smoke/Heat Alarms can be in

Ei Electronics EIB140RC Series The EIB140RC series may be interconnected with

any other Brooks RadioLINK or RadioLINK+ products through fitting onto an EIB168RC RadioLINK Base. This base will enable the EIB140RC series Alarms to communicate RF messages to other Brooks products such as the EIB450 RadioLINK Alarm Controller where you can remotely locate, test and hush your EIB140RC Series Alarms using this wireless controller. For detailed instructions on using the RF interconnection base

Check all Alarms weekly, especially after initial

installation or re-occupation (e.g. following a holiday) 1. Check that the green mains indicator light is on. (if it is off check circuit breakers, fuses and wiring etc.) 2. Check that the red LED on the cover flashes once every 40 seconds to indicate normal operation – If the memory has been set indicating that the Alarm has been activated in the last 24 hours, the red LED will flash twice every 40 secon

If the unit is beeping: Before replacing the battery,

check that the beeps are not due to one of the following: (i) battery snaps not connected properly. (ii) On the Optical Smoke Alarm only (EIB146RC) if the unit beeps and the red light does not flash at the same time it indicates a problem with the smoke chamber - see “Cleaning Your Alarm” section. (iii) If the beeps have continued for over 20 minutes (and the other causes of beeps have been ruled ou

Ei Electronics EIB140RC Series Check the house carefully in case there is a small fire

smouldering somewhere. Check whether there is some source of smoke or fumes, for example cooking fumes being drawn past the Smoke Alarm by an extractor. If there are frequent nuisance/false alarms it may be necessary to re-locate the device away from the source of the fumes or replace an Ionisation Alarm with an Optical Alarm. If for some reason the Alarm continues to sound without smoke or heat being

3. Get out as fast as you can.

Do not stop for packing. Have a prearranged meeting place outside for all family members. Check everybody is there. 4. Call the Fire Brigade immediately on a mobile phone or from a neighbour’s house. Make sure to call the Brigade for all fires no matter how small - fires can suddenly spread. Also call the Brigade even if the alarm is automatically transmitted to a remote monitoring centre - the link may have failed. 5. N

the unit may beep or alarm in the post. State the nature

of the fault, where the Alarm was purchased and the date of purchase. Brooks guarantees this Alarm to the original consumer purchaser for five years from date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from normal wear and tear, incorrect installation, use

Brooks Australia PTY Ltd.

4 Pike Street, Rydalmere NSW 2116 Australia Tel: 0296841466 www.brooks.com.au Ei Electronics. Shannon, Co Clare, Ireland. Tel: 061 471277 www.eielectronics.com Contact Us Conforms To AS3786:2014

Ei Electronics EIB140RC Series ALARM SHOULD BE CEILING MOUNTED AT LEAST 300mm FROM

WALLS & OBSTRUCTIONS, IDEALLY CENTRALLY IN ROOM/AREA WIRE TO TERMINALS ON THE BASEPLATE AND FIX BASEPLATE TO CEILING USING THE FIXINGS PROVIDED LOCATE CORRECT SITING POINT 1 SLIDE ALARM ONTO BASEPLATE. A CLICK SHOULD BE HEARD AS THE TAMPER-PROOF CATCH ENGAGES SLIDE ON ALARM 3 LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM THE SLOT IS LOCATED DIRECTLY A

Ei Electronics EIB140RC Series The minimum number of smoke Alarms is set out in the

National Construction Code (NCC) Building Code of Australia: Volumes 1 and 2, and/or the relevant State or Territory Building Regulations. The main reason for fitting Smoke & Heat Alarms in dwellings is to ensure that when there is a fire, sufficient early warning is given so that everybody can escape safely. This means that the fire alarms should ideally be located near all potential sources of fires an

Ei Electronics Smoke Alarm Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
Ei141

Ei141 Product manual - Z2XL59

2 0.1 Mb 1138 171 29-04-2026
Ei100TY

Guide: Ei Electronics Ei100TY (8Z619N, Upd.13-07-2026)

14 429 95 13-07-2026
RadioLINK Ei 407

Ei Electronics Smoke Alarm Operation & user’s manual (File: PDF, 18-04-2026)

2 0.06 Mb 1084 174 18-04-2026
Ei160e Series

Ei Electronics Smoke Alarm Instruction manual (File: PDF, 10-10-2026)

16 782 133 10-10-2026
Ei105R

Ei105R Product manual - 818933

2 0.11 Mb 550 127 15-09-2026
Ei 156TLR

Smoke Alarm #98UCG9

2 0.11 Mb 461 88 16-09-2026
Ei175

Ei175 Product manual - PPNI19

2 0.09 Mb 979 187 04-09-2026
Ei175 Ionisation

Ei175 Ionisation (Smoke Alarm ePDF Guide, #8EF143)

2 0.2 Mb 291 70 03-09-2026
EiA207 Series

PDF User Manual (@9KT42L), Ei Electronics EiA207 Series Smoke Alarm (29-06-2026)

12 1444 289 29-06-2026
Ei 225E

Ei Electronics Smoke Alarm User instructions (File: PDF, 25-04-2026)

6 0.14 Mb 468 108 25-04-2026

Smoke Alarm: Similar Manuals