Ei Electronics EIB140RC Series Instruction Manual
| Brand: | Ei Electronics |
| Category: | Smoke Alarm |
| Model: | EIB140RC Series (Instruction Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 16 |
Text of Ei Electronics EIB140RC Series Instruction Manual
© Brooks 2018
P/N B18866Rev1
230V~ SMOKE & HEAT ALARMS
EIB140RC Series
Instruction Manual
with Alkaline Battery Backup
The EIB140RC series is supplied with an Easi-Fit
base that allows very quick and simple installation
of the Smoke Alarm, combined with simple detector
head removal and replacement. The Easi-Fit base
automatically connects both mains power and battery
as the detector head slides on to the Easi-Fit base.
Up to 12 Smoke/Heat Alarms can be in
Ei Electronics EIB140RC Series The EIB140RC series may be interconnected with
any other Brooks RadioLINK or RadioLINK+ products
through fitting onto an EIB168RC RadioLINK Base.
This base will enable the EIB140RC series Alarms to
communicate RF messages to other Brooks products
such as the EIB450 RadioLINK Alarm Controller where
you can remotely locate, test and hush your EIB140RC
Series Alarms using this wireless controller.
For detailed instructions on using the RF interconnection
base
Check all Alarms weekly, especially after initial
installation or re-occupation (e.g. following a holiday)
1. Check that the green mains indicator light is on. (if it is
off check circuit breakers, fuses and wiring etc.)
2. Check that the red LED on the cover flashes once
every 40 seconds to indicate normal operation – If
the memory has been set indicating that the Alarm
has been activated in the last 24 hours, the red LED
will flash twice every 40 secon
If the unit is beeping: Before replacing the battery,
check that the beeps are not due to one of the following:
(i) battery snaps not connected properly.
(ii) On the Optical Smoke Alarm only (EIB146RC) if the
unit beeps and the red light does not flash at the same
time it indicates a problem with the smoke chamber - see
“Cleaning Your Alarm” section.
(iii) If the beeps have continued for over 20 minutes
(and the other causes of beeps have been ruled ou
Ei Electronics EIB140RC Series Check the house carefully in case there is a small fire
smouldering somewhere.
Check whether there is some source of smoke or fumes,
for example cooking fumes being drawn past the Smoke
Alarm by an extractor.
If there are frequent nuisance/false alarms it may be
necessary to re-locate the device away from the source
of the fumes or replace an Ionisation Alarm with an
Optical Alarm. If for some reason the Alarm continues
to sound without smoke or heat being
3. Get out as fast as you can.
Do not stop for packing. Have
a prearranged meeting place
outside for all family members.
Check everybody is there.
4.
Call
the
Fire
Brigade
immediately on a mobile phone
or from a neighbour’s house.
Make sure to call the Brigade
for all fires no matter how small
- fires can suddenly spread. Also
call the Brigade even if the alarm
is automatically transmitted to a
remote monitoring centre - the
link may have failed.
5. N
the unit may beep or alarm in the post. State the nature
of the fault, where the Alarm was purchased and the
date of purchase.
Brooks guarantees this Alarm to the original consumer
purchaser for five years from date of purchase
against any defects that are due to faulty materials or
workmanship. This guarantee only applies to normal
conditions of use and service, and does not include
damage resulting from normal wear and tear, incorrect
installation, use
Brooks Australia PTY Ltd.
4 Pike Street, Rydalmere NSW 2116
Australia
Tel: 0296841466
www.brooks.com.au
Ei Electronics. Shannon, Co Clare, Ireland.
Tel: 061 471277
www.eielectronics.com
Contact Us
Conforms To AS3786:2014
Ei Electronics EIB140RC Series ALARM SHOULD BE CEILING MOUNTED AT LEAST 300mm FROM
WALLS & OBSTRUCTIONS, IDEALLY CENTRALLY IN ROOM/AREA
WIRE TO TERMINALS ON THE BASEPLATE AND FIX BASEPLATE
TO CEILING USING THE FIXINGS PROVIDED
LOCATE CORRECT SITING POINT
1
SLIDE ALARM ONTO BASEPLATE. A CLICK SHOULD BE HEARD
AS THE TAMPER-PROOF CATCH ENGAGES
SLIDE ON ALARM
3
LOCATE THE ARROW ON THE FRONT FACE OF THE ALARM
THE SLOT IS LOCATED DIRECTLY A
Ei Electronics EIB140RC Series The minimum number of smoke Alarms is set out in the
National Construction Code (NCC) Building Code of
Australia: Volumes 1 and 2, and/or the relevant State or
Territory Building Regulations.
The main reason for fitting Smoke & Heat Alarms in
dwellings is to ensure that when there is a fire, sufficient
early warning is given so that everybody can escape safely.
This means that the fire alarms should ideally be located
near all potential sources of fires an
Ei Electronics Smoke Alarm Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
Ei141 |
Ei141 Product manual - Z2XL59 |
2 | 0.1 Mb | 1138 | 171 | 29-04-2026 |
Ei100TY |
Guide: Ei Electronics Ei100TY (8Z619N, Upd.13-07-2026) |
14 | 429 | 95 | 13-07-2026 | |
RadioLINK Ei 407 |
Ei Electronics Smoke Alarm Operation & user’s manual (File: PDF, 18-04-2026) |
2 | 0.06 Mb | 1084 | 174 | 18-04-2026 |
Ei160e Series |
Ei Electronics Smoke Alarm Instruction manual (File: PDF, 10-10-2026) |
16 | 782 | 133 | 10-10-2026 | |
Ei105R |
Ei105R Product manual - 818933 |
2 | 0.11 Mb | 550 | 127 | 15-09-2026 |
Ei 156TLR |
Smoke Alarm #98UCG9 |
2 | 0.11 Mb | 461 | 88 | 16-09-2026 |
Ei175 |
Ei175 Product manual - PPNI19 |
2 | 0.09 Mb | 979 | 187 | 04-09-2026 |
Ei175 Ionisation |
Ei175 Ionisation (Smoke Alarm ePDF Guide, #8EF143) |
2 | 0.2 Mb | 291 | 70 | 03-09-2026 |
EiA207 Series |
PDF User Manual (@9KT42L), Ei Electronics EiA207 Series Smoke Alarm (29-06-2026) |
12 | 1444 | 289 | 29-06-2026 | |
Ei 225E |
Ei Electronics Smoke Alarm User instructions (File: PDF, 25-04-2026) |
6 | 0.14 Mb | 468 | 108 | 25-04-2026 |