Ebac SD100 Owner's Manual
Text of the manual
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
EBAC MODEL SD100/SD200
INDUSTRIAL DEHUMIDIFIER
OWNER’S MANUAL
Ebac Industrial Products, Inc.
700 Thimble Shoals Blvd, Suite 109
Newport News, VA. 23606-2575
Tel: (757) 873 6800 Fax: (757) 873 3632
Website www.ebacusa.com
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
UNPACKING
Carefully remove the SD100/SD200 dehumidifier unit from its transit box and visually check for
signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call
your supplier for advice. Do not discard the packing, it will be useful when trans
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
SPECIFICATIONS
MODEL:
Ebac SD 100
Ebac SD200
HEIGHT:
18.7”
18.7”
WIDTH:
26”
26”
DEPTH:
26”
26”
WEIGHT:
143 lbs
172 lbs
AIRFLOW:
Low 560 CFM
High 760 CFM
Low 560 CFM
High 650 CFM
HORSEPOWER:
1
2
POWER SUPPLY:
110V–115V/60Hz/1ph
208V-230V/60Hz/ ph
FINISH:
Powder-coated Ep
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
INSTALLATION
POSITIONING:
Position the dehumidifier unit in the center of the room to be conditioned if at all possible.
However if a damp patch is particularly apparent the outlet grille should be pointed towards it.
NOTE: Both inlet grille and outlet grille of the dehumidifier unit
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
OPERATION
The following procedures should be followed to test the SD100/SD200 for correct operation:
1) After unpacking, examine all external features to confirm damage-free shipment. Report all
defects and damage at one. Connect the power cable to a grounded power source.
2) Install
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
ROUTINE MAINTENANCE
WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE
HAS BEEN DISCONNECTED BEFORE CARRYING OUT
ROUTINE MAINTENANCE ON ITEMS 1, 2, 4, 5, AND 6.
To ensure continued full efficiency of the dehumidifier, maintenance procedures should be
performed as follows:
1.
Clea
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
REPAIRS
1.
Should an electrical component fail, consult the Factory Service Center to obtain the
proper replacement part.
2.
If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration
technician to correct the fault. Contact the Factory Service Center p
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
TROUBLESHOOTING
SYMPTOM
CAUSE
REMEDY
Unit inoperative
1. no power to unit
1. Check the power from the power
supply panel
Little or no airflow
1. Loose fan on shaft
2. Fan motor burnt out
3. Dirty refrigeration coils
4. Loose electrical wiring
5. Fuse blown or circuit breaker
SD100/SD200 OWNERS MANUAL
Drawing No. :- TPC210
Issue
:- 3
Date
:- 22/06/05
RATING PLATE INFORMATION
SD100
SD200
MOISTURE REMOVAL:
2.5 Liters/hr
4.2 Liters/Hr
REFRIGERANT:
1120 Grams
1650 Grams
VOLTAGE:
115 Volts
208/230 Volts
WATT:
1100
2100
PHASE:
Single
Single
HZ:
60 Hz
60 Hz
9.2 Amp
9.6 Amp
CONTROL VOLTAGE:
24 Volt
24 Volt
TIME DELAY FUSE:
15 A
15 A