PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS Bard Manufacturing Company Bryan, Ohio 43506 Since 1914 . . . Moving ahead, just as planned. Manual: 2100-380 Supersedes: File: Vol II Tab 14 Date: 12-11-00 © Copyright 2000 MIS-1554 ...

Getting Other Information and Publications

For more information, contact these publishers:...... 1 QTEC General Information QTEC Model Nomenclature ...................................... 2 Shipping Damage .................................................... 6 Unit Removal From Skid .......................................... 6 Handling Unit After R ...

Getting Other Information and Publications

These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard. National Electrical Code ..................... ANSI/NFPA 70 Stand ...

FACTORY BUILT-IN ELECTRIC HEAT TABLE

Models QH242DA QH302DA QH242DB QH302DB QH242DC H302DC Q QH362DA QH422DA H482DA Q QH362DB QH422DB H482DB Q QH362DC QH422DC H482DC Q 240V-1 208V-1 240V-1 208V-1 240V-1 208V-1 480V-3 480V-3 240V-1 208V-1 240V-1 208V-1 80V-3 4 KW BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTUH BTU ...

ELECTRICAL SPECIFICATIONS Continued on Page 4 TABLE 2A

� � � � � Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75° C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity” v ...

(continued from Page 3)

Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on 75° C copper wire. All wiring must conform to the National Electrical Code and all local codes. These “Minimum Circuit Ampacity” values are to be us ...

Upon receipt of equipment, the carton should be

checked for external signs of shipping damage. The skid must remain attached to the unit until the unit is ready for installation. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by th ...

HANDLING UNIT AFTER REMOVAL

FROM SKID The unit will have to be turned sideways and removed from the skid to fit through a 36” doorway. If the door height allows, the unit can be slid sideways through the door. If the unit can not be slid through the door, then the unit will have to be put on a cart and tipped down to roll thr ...

INSTALLATION WITH FREE BLOW PLENUM

CEILING 8 FT. - 6 IN. MINIMUM RECOMMENDED CEILING HEIGHT 8 FT. - 4 IN. FLOOR MIS-1573 SUSPENDED CEILING FIXED CEILING DUCT DUCT FLANGE 8 FT. - 7 IN. MINIMUM RECOMMENDED CEILING HEIGHT 7 FT. - 2 IN. UNIT HEIGHT 12 IN. MINIMUM 2 IN. MINIMUM FROM D ...