Synexis SPHERE Setup Instructions
File Specifications
| Brand: | Synexis |
| Category: | Laboratory Equipment |
| Model: | SPHERE (Setup Instructions), prKhlpzOKPC0E |
| File Type: | |
| File Size: | — |
| Pages: | 9 pages |
Download PDF
Download Synexis SPHERE Manual (9 pages)Read Online:
Read the Synexis SPHERE Setup Instructions online using the built-in PDF viewer.
Key Pages of Document
Carefully open shipping box and place foam cover on tabletop. UV bulb is located in the cardboard tube (shown on the right). Carefully remove UV bulb from the cardboard tube. Position Sphere face-down on foam insert on a tabletop. Select L-shaped TORX tool to remove safety screws. Remove top safety screw. 1 2 4 5 6 Locate power cord an ...
Match wide UV-A bulb pins to wide pattern in the bulb socket. With wide pins on the left, insert UV-A bulb into bulb socket. Gently press bottom of bulb to ensure it is fully inserted. Replace bulb cover. 12 13 14 15 Tighten UV bulb cover safety screw. Tighten top safety screw. 16 Remove bulb cover. Tighten bottom safety screw. 1 ...
L-shaped TORX tool. Remove bottom safety screw with the L-shaped TORX tool. Grab recess and pull top and bottom of cover to disengage magnets. Remove front cover. Locate slot for Sail. Holding tabs, insert Sail into slot. Position top pin over slot. Let magnet re-engage. Fasten safety screws. Sphere Sail Installation 3 6 7 ...
On front cover, turn the white tabs 90 degrees. First, remove the carbon filter. Then, remove old MERV 11 filter. Insert new MERV 11 filter with airflow arrow pointing toward you. Replace carbon filter on top of the MERV 11 filter. Rotate white tabs 90 degrees to secure both filters into place. Check compartment for loose debris. 4 5 6 ...
Locate wall mount bracket. Use a level to properly align bracket to mounting location. Mark drill holes on wall using the bracket as a guide. Use appropriate-sized screws to secure wall mount bracket to the wall. Position Sphere to mounting bracket, aligning mounting screws with the outer holes on the bracket. Slide Sphere down onto w ...
on the wall. Remove rubber grommet. Select green T-handle screwdriver. Tighten security screw. Make sure security screw is tight- ened all the way. Re-insert rubber grommet into security screw hole. To re-install front cover, position top and bottom pins over slots. Let magnets re-engage. Rubber grommet is now in place. Push ...
2 3 4 5 Align legs of metal stand to the two recessed holes on bottom of Sphere with horizontal piece closest to you. Squeeze ends slightly together to fit second leg into recessed hole on the right side. Insert first leg into left recessed hole. Insert and tighten screw to secure left leg. Insert and tighten screw to secure right leg. R ...
is fully inserted. Connect power cord to the Sphere device. Powering Up the Sphere To adjust the device airflow, use the 3-speed fan speed control switch. Locate power cord. Green indicator will illuminate when the power is on. Turn on power switch. 1 2 3 5 6 4 SYN-GEN-1220-006 ...
⚠️ Download Safety
The Laboratory Equipment Setup instructions (9 pages) is completely safe to download (last scan date: 18/06/2026).
Related PDF Instructions for Synexis SPHERE:
-
Synexis SPHERE Air Cleaner Manual , 8 pages
-
Synexis SPHERE Laboratory Equipment Setup instructions, 9 pages
-
Synexis Sentry Air Cleaner Owner's manual, 16 pages
-
Synexis SPHERE Air Cleaner Owner's manual, 14 pages
-
Synexis Blade Inline Air Cleaner Owner's manual, 15 pages
-
Synexis SPHERE Air Cleaner Quick start manual, 6 pages