suprema Secure I/O 2 Installation Manual

File Specifications

Brand: suprema
Category: Control Unit
Model: Secure I/O 2 (Installation Manual), prl.hhmxMn/q.
File Info: Adobe Acrobat PDF (DjVu)
File Size: —
Pages: 14 pages

Download PDF

Download suprema Secure I/O 2 Manual (14 pages)

Read Online:

Read the suprema Secure I/O 2 Installation Manual online using the built-in PDF viewer.

Key Pages of Document

Safety Instructions ................................................................................ 3

Components ............................................................................................. 4 Front Side ................................................................................................ 5 Installation Example .......... ...

Please read the following instructions carefully before using the product. This information is important for ensuring the

safety of the user and for preventing damage to the user's property. Warning Violation of the instructions may cause serious injury or death. Installation Instructions Do not install the product i ...

Components may vary according to the installation environment.

Secure I/O 2 Bracket (2 pcs) Mounting screws for bracket (2 pcs) 120Ω resistor (1 pc) Diode (1 pc) ...

Press INIT button to reset Secure I/O 2 interworking with a device and then connect to another device.

LED status indicator for RS-485 D- (TRX-) LED status indicator for RS-485 D+ (TRX+) RS-485 D+ (TRX+) RS-485 D- (TRX-) RS-485 GND Relay Output Normally Closed Relay Output Common Relay Output Normally Open INIT button: Relay ...

Secure I/O 2 is connected with RS-485 and can be installed anywhere due to its small size. It can be installed with a

junction box or onto a wall control box already installed. It can be installed at the rear side of an Exit button. Exit button External input RS-485 Access controller Door lock device Relay output ...

Cable should be AWG22~AWG16.

• To connect the cable to Secure I/O 2, strip off approximately 5~6 mm of the end of the cable and connect them. Power • Do not share the power with the access controller. • If the power is shared by other devices, it should provide 9–18V and a minimum of 500 mA. • When using a power a ...

Fail Safe Lock

• To use fail safe lock, connect NC terminal as shown below. Normally, there is a current flowing through the relay and the door is opened when the relay is activated by blocking current flow. The door will also be opened when there is a blackout or power failure caused by external conditions. NOTE • When deadbolt or do ...