901 San Antonio Road

Palo Alto, CA 94303-4900 USA 650 960-1300 Fax 650 969-9131 Sun™ Enterprise™ 250 Server Product Notes Part No. 806-0023-10 February 1999, Revision A Sun Microsystems, Inc. Send comments about this document to: [email protected]

Sun Microsystems Enterprise 250 Copyright 1999 Sun Microsystems, Inc., 901 San Antonio Road • Palo Alto, CA 94303 USA. All rights reserved.

This product or document is protected by copyright and distributed under licenses restricting its use, copying, distribution, and decompilation. No part of this product or document may be reproduced in any form by any means without prior written authorization of Sun and its licensors, if any. Third-party software, including font tech

Sun Enterprise 250 Server

Product Notes These Product Notes contain late-breaking product information that is not included in the system or the multimedia documentation for Sun Enterprise™ 250 servers. Included in these Product Notes are the following topics: I “About UltraSPARC II CPU Modules” on page 2 I “CPU Module Configuration Rules” on page 2 I “Removing and Installing a CPU Module” on page 2 I “System Software Requirements” on pa

Sun Enterprise 250 Server Product Notes • February 1999

About UltraSPARC II CPU Modules The Sun Enterprise 250 server supports up to two 250-, 300-, or 400-MHz UltraSPARC™ II CPU modules. The new 400-MHz UltraSPARC II CPU module has 2 Mbytes of integrated cache memory. Identifying Your CPU Module Before installing your CPU module, verify that the module is one of the following UltraSPARC II modules for Sun Enterprise 250 server systems. The following

Sun Microsystems Enterprise 250 Sun Enterprise 250 Server Product Notes

3 Caution – Before you install any CPU module, read the section “Main Logic Board Jumpers” on page 3, and verify that the jumper setting is correct for the speed of the CPU module you are installing. Serious system damage can result if your main logic board clock mode jumper is set incorrectly. To remove or install CPU modules in the Sun Enterprise 250 server, follow the instructions in the sections “How to R
Sun Enterprise 250 Server Product Notes • February 1999 Set the clock mode jumper shunt at address J3001 to correspond to the speed of your UltraSPARC II CPU module. Verify that the jumper setting is correct before starting the system. The illustration below shows the jumper locations for the main logic board. Jumpers are marked on the main logic board with identification numbers. For example, the UPA clock divide jumper is marked J3001. Jumper Shunt o
Sun Enterprise 250 Server Product Notes 5 Jumper pins are located immediately adjacent to the identification number. Pin 1 is marked with a single asterisk (*) in one of the positions in the following illustration. Remote System Control (RSC) Software Sun™ Remote System Control (RSC) software is included on the Sun Enterprise 250 Supplement CD (provided with your server). For additional details, please see the documentation included with the Sun Enterpri

Sun Microsystems Server Owners Instructions: