SOLaVent 230 Quick Start Manual
| Brand: | SOLaVent |
| Category: | Home Lighting |
| Model: | 230 (Quick Start Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 10 |
Text of SOLaVent 230 Quick Start Manual
230 Sola-Vent System
Dec 2006
Components
SunPipe Components
1 x 230 SunPipe Diamond Dome
1 x Integral ABS Flashing Plate with Extract Duct
1 x Code 4 lead skirt
1 x SunPipe Extension 610mm Length – Crimped End
1 x SunPipe 30° or 45° Adjustable Elbow
1 x SunPipe Standard 610mm Length - Plain End
1 x SunPipe 250mm Long Bell End Ceiling Extension
1 x SunPipe Ceiling Trim
1 x SunPipe Ceiling Bezel
1 x Silicone Sealant
1 x SunPipe Installation Pack
Sola-Ven
Installation instructions: Monodraught Sola-vent
(All mains wiring should be carried out by a qualified electrician.)
DO NOT Connect the internal batteries until the installation has been fully
completed. Failure to do so may cause damage to the system.
1. Check to ensure that there is sufficient room for the ventilation ductwork and
SunPipe lengths between the bathroom ceiling and the selected position of the
roof flashing and that a suitable mains lighting circuit is available to the
bathroom ceiling for the Halogen downlights, connected to the bathroom light
switch and
SOLaVent 230 Vent flashing and up to 9m away from the Base unit. (Additional
extension cables are available from Monodraught tel 01494 897700)
b. Fit the solar panel flashing plate as per the SunPipe standard flashing
plate installation instructions.
c. The cable should be passed through the roofing felt by making a small
hole through it.
d. Secure the cable internally by taping it to the SunPipe system using the
silver tape supplied with the SunPipe.
6. Place the plyw
SOLaVent 230 11.Insert the cast metal holders for the downlighter units into the ceiling fascia,
ensure that the securing clips are securely located. Fit the bulbs and retaining
clips as per the manufacturer’s instructions.
12.Connect the Miniature PIR using the three core cable
provided. If a male to female connector is included
this will be a simple push fit to join together. One
cable will be already fitted to the fascia and one to
the base unit. If there is not a
SOLaVent 230 16.Position the fan in place within the fan housing below the Sola-Vent flashing
plate. Take note of the direction arrows on the side (Arrow should point towards
roof) and check that the fan spins freely without any obstruction from the foam
gasket.
17.Secure to the housing fitted to the underside of
the roof unit using the nuts and bolts supplied. If
there are any gaps between the two plates these
can be taped together using the silver tape
supplied with
21.Having checked that the electricity supply is disconnected, connect the mains
wiring to the Downlighters from the switched mains lighting circuit using the
two brown connector blocks supplied. Ensure that no bare wire is showing and
insulate with electricians tape if necessary. (All mains wiring should be
carried out by a qualified electrician.)
22.Having checked all wiring connections for safety reconnect the mains supply
and test the mains lights usi
Maintenance instructions: Monodraught Sola-vent
The Monodraught Sola-vent is designed to run with little or no maintenance
for years of trouble-free service.
� The Sola-vent has a number of non-serviceable components in the ABS
base unit and these may be replaced by a qualified electrician if
necessary. The solar batteries, have a five year life expectancy and you
will be automatically contacted when these are due for renewal.
� Occasional cleaning of