Manufacturer reserves the right to make modifications in order to improve device operation.

tel.: (12) 626 46 92 fax: (12) 626 46 94 E-mail: [email protected] Internet: www.pxm.pl Rev 1.0 PXM Marek Żupnik spółka komandytowa Podłęże 654 32-003 Podłęże CONTENTS 1. General description.................................................................................................... 2. Safety conditions................................................... ...

1. GENERAL DESCRIPTION

2. SAFETY CONDITIONS Caution! Before installing, connecting and using the lamp you have to absolutely read this document. The following symbols are used to underline important information on security conditions on the product and in this manual. PxArt + 3 is a professional LED illuminator designed to illuminate museum and exhibition displays. _ By using the latest semiconductor light sources and advanced control ® OSLON Square e ...

In case of improper usage of the product it may cause a risk of serious injury or death

because of the threat of fire. While working at an ambient temperature of 25°C housing unit can heat up to 90°C. Because of the danger of burns, avoid direct contact with the casing. Device PX389 is powered directly from standard 230 V grid what can cause electric shock when safety rules are not observed. Therefore it is necessary to observe the following: 1. Instal ...

There are several versions of the PX393 lamp which are different from each other in the angle

of the reflector applied, a colour rendering index, colour temperature and colour of the housing. Below there is a description of designations of PX393 models with explanation: PX389-XX-UYY-Z XX - the reflector angle Available values: o 10 - 10 o 22 - 22 o 40 - 40 U - CRI colour rendering index 8 - 80 9 - 90 YY - Colour temperature 30 - 3000K 50 - 5000K Z - Lamp h ...

4. LAMP DESCRIPTION

1 2 3 4 a three-phase track for control systems ® GLOBAL Trac Pulse Control end feed power cable DMX cable (shielded cable, two-core cable) adapter GLOBAL Trac GAC 600 5 5. DMX SIGNAL AND POWER CONNECTION 5.1. Adapter GLOBAL Trac GAC 600 5 1 2 3 4 CONTACTS DMX POWER CONTACTS neutral (phase 3 on the opposite side) phase selector switch phase 1 (phase 2 on the opposite side) earth DMX - (on the ...

5.2. Section through the DMX GLOBAL Trac Pulse control current

rails. 7 1 2 3 4 5 6 phase 3 phase 1 phase 2 neutral DMX + GND DMX - POWER DMX The lamp has been equipped with a button which allows for changing the brightness level. The button has been placed at the bottom part of the junction box, above the lamp reflector. The layout of the button and connectors for connecting the PX277 programmer has been shown in the f ...

7. CO-OPERATION WITH THE PX277 CONFIGURATOR

Lamp settings can be changed by connecting the PX277 PxArt Settings Controller configurator. _ At the moment of connection, the PX389 starts again which causes LEDs to be off for a while and the diode indicating the DMX signal condition pulses for 2 seconds. Once connection has been established and the parameters have been read by PxArt Settings Controller, lamp settings return to the state before the connecti ...

Temp. min max

23.0°C 53.3°C Current temp. 25.5°C Bright. address 00y 001d 06h: 48m Working time 00y 000d 07h:00m 5x NEXT NEXT NEXT NEXT Serial Number 2015350050 Version ver 2.14 NEXT NEXT 9 7.1. Description of the information parameters PX277 controller allows you to read important information concerning the lamp to which it has been connected. Lamp operation time (total operation time of the lamp, also without diodes turned on) and ...

PX389 +3 MONO

2x NEXT Smooth Off * Smooth P2P * NEXT Smooth Time * NEXT Smooth Time ENTER Model PX389 +3 MONO 3x NEXT Smooth time 0200[ms] Smooth time 0010[ms] * Smooth time 2000[ms] * NEXT ENTER Model PX389 +3 MONO 4x NEXT 10 8.2. Scene brightness Lamps from PxArt series can work without using DMX control. In such case, PxArt Settings Controller enables changing the scene brigh ...

8.5. Restoring default settings

The device comes with the option to restore default settings. To use this option, select the [Default sett.] menu and press "enter". A window informing about the need to press "previous" and "next" buttons will appear for 2 seconds simultaneously. Next, the device will display [Reset OK]. The acceptance of this message by using "enter" restores default settings. There is also a possibility to exit the level of this menu w ...

device description, e.g. name

MANUFACTURER_LABEL 0x0081 manufacturer description, e.g. name DEVICE_LABEL * 0x0082 additional device description, It is possible to enter an additional device description using up to 32 ASCII characters. FACTORY_DEFAULTS 0x0090 device default settings DMX_PERSONALITY 0x00E0 DMX operational mode DMX_PERSONALITY_ DESCRIPTION 0x00E1 description of individual oper ...

PX389 +3 MONO

Smooth Off Smooth time 0200[ms] Bright. address 001 Scene bright. 000 NEXT Working time 00y 000d 07h: 48m Temp. min max 23.0°C 53.3°C Default sett. Lighting time 00y 001d 06h: 48m Current temp. 25.5°C ENTER Serial Number 2015296666 Version ver 2.13 Bright. address 001 * Bright. address 512 * NEXT Scene bright. 000 * Scene bright. 255 * NEXT ENTER Smooth Off * Smooth P2P * NEXT Smooth Time * NEXT ENTER Smooth time 0010[ms] * Smoo ...

Number of LEDs:

Power input: Max. increase of the housing temperature: Luminous flux: Lifetime of diodes: Angles of reflectors: Colour temperature: Brightness regulation extension: CRI colour rendering index: Control protocol: Available housing colours: Weight: Dimensions: 230 V AC 3 10 W + 20° C 540 lm in versions 90 CRI lub 680 lm in versions 80 CRI 50 000 h 10°, 22°, 40° 3000 K and 5000 K 0÷100% 80 or 90 DMX-512 / RDM Grey, black and whit ...

PXM Marek Żupnik sp. k.

ul. Przemysłowa 12 30-701 Kraków PxArt+ 3 PX389 PN-EN 60598-1:2011 PN-EN 62471:2010 PN-EN 61000-4-2:2011 PN-EN 61000-6-1:2008 PN-EN 61000-6-3:2008 Pay attention to the correct connection of power cables. Maintenance can be performed only while the current rails system is off. DMX signal has to be connected by using a shielded cable, connected to the GND pin. mgr inż. Marek Żupnik tel: 12 626 46 92 fax: 12 626 46 94 e-mail: ...