PXM PX314 Operation & User’s Manual
Read Online
Read the PXM PX314 Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
1 Description...................................................................................................4 2 Safety conditions........................................................................................5 3 Control elements........................................................................................7 3.1 Knob....................................................................................................... ...
7 Dimensions...............................................................................................31 8 Technical data..........................................................................................32 Manufacturer reserves the right to make modifications in order to improve device operation. PXM Marek Żupnik sp.k. Podł ...
AC+ Dimmer 24 x 3600W can be powered by three phases, and has an integrated system fully protecting against the effects of reverse phases connection. The device allows yo control 24 independent channels with a power of 3.5kW each. The dimmer enables to control input signals from 6 different sources simultaneously, including: • 2 x DMX-512 lines • 3 x Art-Net lines • 24 x analo ...
and the program are available to be defined. The integrated “PLL”, “soft-start”, “soft-on” and “even-off” systems assure reliable operation in the most extreme conditions. Direct detection of zero of the network and optical insulation of DMX input guarantee high resistance to interface. PX314 has a solid metal housing with an efficient cooling system, adapted for wall m ...
of the same technical parameters. 5. Use only 3-wire cables of not less than 2,5mm2 for connecting devices to the dimmer. 6. Each receiver should be powered by a separate cable. 7. After installation, test the effectiveness of resetting all the equipment controlled. 8. All repairs that require the housing to be removed can only be carried out with power disconnected. 9. The dimmer ...
480 x 272px. During operation, it displays basic information and possible warning and errors. The displays also allows to set the parameters of the dimmer. You may be asked to give a password to enter the settings menu. 3.1 Knob It is used to quickly change the numerical values in the boxes and switch between successive elements on the screen. Pressing the knob is equ ...
• Enter – it activates the selected item. If the selected item is a key – it presses this key, if a list – it expands this list, if a text box – it starts to edit it. • Next / Prev – they are used to switch between successive items on the screen and select values from the list and numeric fields • Esc – it allows to cancel the changes 3.3 Interface During the p ...
: Start screen is visible to every user, without a password. 4.1 Summary screen Pressing the [INFO] key takes you to the summary screen. This screen includes the following information : 9 name and number of the dimmer information whether the device requires you to give a password (the symbol of an open or closed padlock), and clicking it causes log out addresses of the f ...
errors is detected in the dimmer : • DRIVER HIGH TEMPERATURE – warning about exceeding the maximum temperature set in the FAN menu • PHASE LOSS – error, no voltage on the phase (contact the service) • PHASE ERROR 1 – internal error (contact the service) • MODULE NOT RESPONDING – error, no communication with the unit (contact the service) • DRIVER TERMISTOR MISSIN ...
The channel summary screen [CHANNELS INFO] shows keys corresponding to 24 output channels. Each key shows : The colors of captions depend on the source of value on the channel: x violet – DMX 1 x orange – Art-Net 3 x blue – DMX 2 x brown – analog input x green – Art-Net 1 x black – no signal x yellow – Art-Net 2 Pressing one of the channel keys takes you to the corresponding channel summary screen. This screen disp ...
the screen with available keys : CHANNELS - setting the parameters of output channels PROGRAM - defining the scenes and program that can be activated in the absence of DMX signal PATCH - addressing inputs and merge mode for individual inputs SETTINGS - other settings 5.2 Setting the channel parameters After selecting [CHANNELS PARAMETERS], you can set the paramet ...
: • LINEAR – the value on the output is directly proportional to the input value • EXPONENTIAL – exponential characteristics • LOGARITHMIC – logarithmic characteristics • ON/OFF – two-level characteristics • REVERSED – the value on the output is inversely proportional to the input value • USER 1 – 5 – 5 curves to be defined by the user Pressing the [ESC] key exits the screen without saving ...
program that can be activated in the absence of DMX signal. Scene is a static adjustment of the value at the output channels. Program is a set of successive scenes. The screen shows the following keys : EDIT SCENE - editing on of 128 scenes COPY SCENE - copying set values between the scenes CAPTURE SCENE - capturing the current scene output status EDIT PROGRAM - defining the order of ...
Scene edit screen includes : When you select [EDIT SCENE], the application displays the screen for editing scene 1; in addition, scene 1 occurs on the outputs. [NEXT] and [PREV] keys allow to switch between the scenes. Transitions are made in a linear way. 5.3.2 Scene copying Scene copying screen contains 2 fields: [FROM] and [TO] which allow you to specify the source scene and the target scene between which the values are to be copied ...
Scene capture option allows to save current values on the output channels to the selected scene. Scene capture screen includes : [NEXT] and [PREV] keys allow to switch between the scenes. 5.3.4 Program edit The program edit screen shows a list of 64 steps and scenes corresponding to these steps. 5.3.5 Playback The playback screen [PLAY] allows to preview the created scenes and program. On the screen, there are keys to play and stop t ...
The [BACK] key which exits the screen. 5.3.6 No signal By using the [NO DMX SIGNAL] screen, you can program the operation of the device in the absence of DMX signal. Available options : • ON – all channels will be enabled at 100% • OFF – all channels will be disabled • SLOW TURN OFF – there will be a slow blanking of all channels • HOLD – the last value present ...
includes the following fields : Available values of the merge mode : • HIGH – the highest of value • LAST – last value • DMX1 – value from the DMX 1 input • DMX2 – value from the DMX 2 input • UNIVERSE 1 – value from the Art-Net 1 input • UNIVERSE 2 – value from the Art-Net 2 input • UNIVERSE 3 – value from the Art-Net 3 input • is DMX1/DMX2 – value ...
from the DMX 2 input is selected. If you disable DMX 2, value from the DMX 1 is selected only when it reaches the DMX 2 input value. • is DMX1/UNVRS 1 – value from the DMX 1 input, if there is a signal on it, if not – UNIVERS 1 input • is DMX1/UNVRS 1 CAPT. – if DMX 1 and UNIVERS 1 are enabled, value from the DMX 1 input is selected. If you disable DMX 1, value from the UNIVERS 1 ...
: CURVES - management of characteristics curves ADMIN - administrator settings ARTNET - Art-Net settings FAN - fan settings LCD - display settings LAN - network settings 5.5.1 Curves 10 curves are available in the device: 5 preset and 5 user-definable. Preset curves can be previewed and copied. User’s curves can be edited. The [CURVES] screen includes 10 keys for all the curves : • LI ...