Check the approved dimensions of the suction line.
Align the HRP 3232, 5050-90 and 8050-90 exactly vertically.
Align the HRP 5040 to 10080 up to 40bar exactly horizontally.
Connect the pump stress-free. Do not use the flange screws to align or stretch the
piping.
Connect the cables with a loop (see photos on the back).
Safety devices
The
Necessary suction line Ø
Required minimum flow
Orifice for CO2
HRP
DN
inch
50 Hz
60 Hz
HRP Frequency
Part-No.
50 Hz
60 Hz
m3/h
gal/min
m3/h
gal/min
3232
50 Hz
4.419.020.104
3232
80
3
0,6
2.6
0,7
3.1
60 Hz
4.419.020.114
5040
100
5
1,2
5.3
1,5
6.6
5050
50 Hz
4.419.020.103
5050
125
5
3
13.2
3,5
15.4
60 Hz
4.419.020.113
8050
150
8
5
22
5,5
24
8050
50 Hz
4.419