Easy BKW klavier quick guide voor gebruik icm SK-ACP E centrale :
-
In programmatie gaan –
o duw de # toets gedurende 2s – Transmit LED gaat uit en Program
LED wordt Rood
o duw je 4cijferige programmatiecode (fabrieksinstelling 1234)
o indien ok wordt Program Led groen
o Om uit programmatie te gaan: duw de # waarna de Program Led
uitgaat & Transmit LED groen wordt
-
Selecteer transmissieformaat:
o Ga in programmatiemodus
o Duw 1 om Menu1 in te gaan –
EASYKW - EASYBKW
ENGLISH
ISEASYKW_12_04.doc
1
1. INTRODUCTION
The EASYKW is a vandal resistant programmable keypad reader. The
Wiegand output allows the connection to a large number of access
control devices.
Model EASYBKW is provided with LED backlight.
2. MAIN TECHNICAL FEATURES
Operating Voltage Range:
5 – 16 Vcc
Maximum Input Current:
20mA in standby (60mA max.)
With backlight
(EASYBKW only):
50mA in standby (90mA max.)
Transmission formats:
� 1 t
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
2
4. WIRING
The reader is supplied with a 6-conductor cable about 40 cm., to
connect the Reader, perform the following steps:
1)
Prepare the Reader cable by cutting the cable jacket back 3 cm
and strip the wire 1,5 cm. Prepare the Controller cable at the
same way.
2)
Splice the Reader pigtail wires to the corresponding Controller
wires and cover each connection.
COLOR
OUTPUT
RED
+VDC
BLACK
GND
WHITE
DATA1 / CLOCK
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
3
6. PROGRAMMING THE EASYKW
Programming the EASYKW is done solely via the unit's keypad driven
Programming Menu System (see par. 6.1).
During the EASYKW's manufacturing process certain codes and
settings are pre-programmed. These settings are the called the
"Default Factory Settings".
The table below shows the names of all the EASYKW Menus.
Menu Description
Menu
number
Selecting keypad transmission format
1
Chan
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
4
6.2
Exiting Programming Mode
1)
To exit the Programming Mode at any time: Press the "#" key,
You will hear a beep, The Program LED will be off The Transmit
LED will turn green. This indicates that the EASYKW has
returned to Transmit
Mode.
2)
Wrong entries may
reset the reader back
to Transmit Mode.
3)
While in Programming Mode if no key is pressed for 30 seconds
the EASYKW will exit Programming Mode and return
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
5
See the table below to determine the Option Number for the Keypad
Transmission Format you wish to select.
Keypad Transmission Format
Option
Number
1 to 5 keys + Facility Code, 26-bit Wiegand
5
1 to 8 Keys , Clock & Data
8 + n. digit
30-bit Wiegand
9
6.3.1
OPTION 5 -- 1 to 5 Keys + Facility Code, 26-Bit Wiegand
Buffers up to 5 keys and outputs keypad data with a facility code like a
26-Bit card output. The facil
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
6
6.3.2
OPTION 8 -- 1 to 8 Keys , Clock & Data
Buffers up to 8 keys and outputs keypad data without a facility code
like standard Clock and Data card output. The keypad PIN code can be
one to eight digits long. The PIN code length is selected while
programming the reader for Option 8. The reader will transmit the data
when it receives the last key press of the PIN code. The data is sent
across the two data output
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
7
7. Changing the Programming Code
1)
Enter Programming Mode
2)
Press "3" to enter Menu 3: the
Transmit LED will flash red.
3)
Enter the new 4-digit code you
wish to set as the Programming
Code.
You will hear one beep
� The Program LED will turn off
� The Transmit LED will turn red
NOTE: Programming Code can not
be erased, i.e. the code 0000 is not
valid
and
will
not
erase
the
Programming Code.
8. Changing t
EASYKW - EASYBKW ENGLISH
ISEASYKW_12_04.doc
8
9. Return to Factory Default Settings
Warning: You must be very careful before using this command!
Doing so will erase the entire memory which includes all User and
Special Codes, and return all codes to their factory default
settings.
1)
Enter Programming Mode.
2)
Press "0" to enter Menu 0
� The Transmit LED will
flash red
� The Program LED will flash red
3)
Enter your 4-digit Programming Code
� If the
EASYKW - EASYBKW FRANÇAIS
ISEASYKW_12_04.doc
1
1. GENERALITES
EASYKW est un lecteur à clavier programmable antivandale. La sortie
au standard Wiegand permet d’être relier à la plupart des appareils de
contrôle d'accès qui se trouvent sur le marché.
La version EASYBKW est équipée de rétroéclairage.
2. CARACTERISTIQUES TECHNIQUES
PRINCIPALES
Tension d'alimentation:
5 – 16 Vcc
Courant absorbé:
20mA en veille (60mA max.)
Avec rétroéclairage
(
EASYKW - EASYBKW FRANÇAIS
ISEASYKW_12_04.doc
2
position désirée et remonter la façade à l'aide des vis et de la clé en L
contenues dans le kit.
4. RACCORDEMENTS
Le lecteur est équipé d'un câble 6 broches d'environ 40 cm; pour
effectuer la liaison, procéder comme suit:
1)
Préparer le câble du lecteur en découvrant le bas d'environ 3
cm et en le dénudant d'environ 1,5 cm. Préparer également de
la même façon le câble du contrôleur.
2)
Rel
EASYKW - EASYBKW FRANÇAIS
ISEASYKW_12_04.doc
3
6. PROGRAMMATION DU LECTEUR EASYKW
La programmation du lecteur EASYKW s'effectue uniquement par le
système menus du clavier auquel on accède en entrant en mode
programmation (voir paragraphe 6.1)
A l'achat, le produit contient déjà des codes et des paramètres
prédéfinis, qu'on appelle “Paramètres par défaut”.
Le tableau ci-après indique les noms de tous les menus du clavier.
Description du menu
PRASTEL IP Access Controllers Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
MEGAPROX2-P |
PRASTEL IP Access Controllers Quick start manual (File: PDF, 08-06-2026) |
4 | 535 | 86 | 08-06-2026 | |
EASYBKA |
PRASTEL EASYBKA Manual (Manual ), @7P2951 |
27 | 406 | 70 | 08-06-2026 | |
MT4000-2 |
PRASTEL IP Access Controllers Manual (File: PDF, 27-09-2026) |
25 | 422 | 76 | 27-09-2026 | |
M2000PE |
#22SNX2: M2000PE IP Access Controllers Quick start manual |
4 | 1015 | 193 | 07-05-2026 | |
EASYKA |
PRASTEL EASYKA User Guide (Manual ), @8VNT9Q |
20 | 21 | 6 | 06-10-2026 | |
EASYKW |
#998J24: EASYKW IP Access Controllers Manual |
17 | 1300 | 273 | 08-06-2026 |