VOLTCRAFT VC190 Operating Instructions Manual
Text of the manual
Seite 2 - 30
Operating Instructions
VC190 Digital multimeter
Item No. 2268246
Page 31 - 56
Mode d’emploi
VC190 Multimètre numérique
N° de commande 2268246
Page 57 - 82
Gebruiksaanwijzing
VC190 Digitale multimeter
Bestelnr. 2268246
Pagina 83 - 108
Bestimmungsgemäße Verwendung .....................................................................................................................5
4.
Lieferumfang ........................................................................................................................................................5
5.
Aktuelle Bedienungsanleitungen .........................................................................................................................5
6.
Merkmale und Funktionen ...................................................................................................................................5
7.
Sicherheitshinweise .............................................................................................................................................6
a) Allgemeines ...................................................................................................................................................6
b) Angeschlossene Geräte ................................................................................................................................6
c) Sicherung ......................................................................................................................................................7
d) Batterien/Akkus .............................................................................................................................................7
e) Multimeter ......................................................................................................................................................7
f) Messspitzen ...................................................................................................................................................8
8.
Bedienelemente und Komponenten ....................................................................................................................9
a) Übersicht .......................................................................................................................................................9
b) Funktionswahlschalter .................................................................................................................................10
9.
Display und Symbole .........................................................................................................................................11
10. Einsetzen/Ersetzen der Batterie bzw. des Akkus ...............................................................................................12
11. Inbetriebnahme und Verwendung ......................................................................................................................12
a) Einschalten ..................................................................................................................................................12
b) Messung von AC-/DC-Spannung ................................................................................................................13
c) Messung von AC-Spannung mit niedriger Impedanz (LoZ) .........................................................................14
d)� Messung�des�Widerstands�(Ω) ....................................................................................................................15
e) Durchgangsprüfung (
) .............................................................................................................................16
f) Diodentest (
) ..........................................................................................................................................16
g) Messung der Kapazität ................................................................................................................................17
h) Messung der Frequenz (>10 Hz) / des Tastverhältnisses (%) .....................................................................17
i) Messung der Temperatur .............................................................................................................................18
j) Messung des Stroms / der Frequenz (40 – 400 Hz) ....................................................................................19
12. Zusatzfunktionen ...............................................................................................................................................20
a) Zugriff auf Unterfunktionen ..........................................................................................................................20
b) Messbereich ................................................................................................................................................20
c) HOLD-Funktion ............................................................................................................................................20
d) Spitzenwerte ................................................................................................................................................21
e) Höchst-/Tiefstwerte ......................................................................................................................................21
f) Abschaltautomatik .......................................................................................................................................22
g) Automatische Hintergrundbeleuchtung .......................................................................................................22
13. Austauschen der Sicherung ...............................................................................................................................23
14. Problembehandlung ...........................................................................................................................................23
15. Wartung und Reinigung .....................................................................................................................................24
a) Reinigung ....................................................................................................................................................24
b) Wartung .......................................................................................................................................................24
16. Konformitätserklärung (DOC) ............................................................................................................................24
17. Entsorgung ........................................................................................................................................................25
a) Produkt ........................................................................................................................................................25
b) Batterien/Akkus ...........................................................................................................................................25
18. Technische Daten ..............................................................................................................................................26
a) Allgemeines .................................................................................................................................................26
b) Sicherungen ................................................................................................................................................26
c) Messtoleranzen ...........................................................................................................................................27
d) Messung der Kapazität ................................................................................................................................27
e) Durchgangsprüfung (
) und Diodentest (
) ..........................................................................................27
f) Messung von Gleichspannung (DC) ............................................................................................................27
g) Messung von Wechselspannung (AC) ........................................................................................................28
h)� Messung�des�Widerstands�(Ω) ....................................................................................................................28
i) Messung der Frequenz / des Tastverhältnisses ..........................................................................................29
j) Messung von Gleichstrom (DC) ..................................................................................................................29
k) Messung der Temperatur .............................................................................................................................30
l) Messung von Wechselstrom (AC) ...............................................................................................................30
Sehr geehrte Kundin, sehr geehrter Kunde,
wir bedanken uns für den Kauf dieses Produkts.
Dieses Produkt erfüllt die gesetzlichen nationalen und europäischen Anforderungen.
Um diesen Zustand zu erhalten und einen sicheren Betrieb zu gewährleisten, müssen Sie als Anwender diese
Bedienungsanleitung beachten!
Diese Bedienungsanleitung gehört zu diesem Produkt. Sie enthält wichtige Hinweise zur Inbetriebnahme
und Handhabung. Daran sollten Sie auch denken, wenn Sie dieses Produkt an Dritte weitergeben. Heben
Sie deshalb diese Bedienungsanleitung zum Nachlesen auf!
Bei technischen Fragen wenden Sie sich bitte an:
Deutschland:
www.conrad.de
Österreich:
www.conrad.at
Schweiz:
www.conrad.ch
2. Symbol-Erklärung
Das Symbol mit dem Blitz im Dreieck weist
auf Gefahren für Ihre Gesundheit hin, z. B.
Stromschläge.
Das Symbol mit dem Ausrufezeichen im
Dreieck weist auf wichtige Informationen in
dieser Bedienungsanleitung hin. Lesen Sie
diese Informationen immer aufmerksam.
Das
Pfeilsymbol
weist
auf
besondere
Informationen
und
Empfehlungen
zur
Bedienung hin.
Dieses Gerät ist CE-konform und entspricht
den geltenden europäischen Richtlinien.
Schutzklasse 2 (doppelte oder verstärkte
Isolierung, schutzisoliert).
Erdpotential
CAT I
Messkategorie I erlaubt die Nutzung des
Geräts für Messungen an elektrischen
und
elektronischen
Geräten,
die
nicht
direkt
mit
Netzspannung
versorgt
werden (z. B. batteriebetriebene Geräte,
Schutzkleinspannungen,
Signal-
und
Steuerspannungen usw.).
CAT II
Messkategorie II erlaubt die Nutzung des
Geräts für Messungen an elektrischen
und
elektronischen
Geräten,
die
über einen Netzstecker direkt an das
Niederspannungsnetz angeschlossen sind.
Diese Kategorie umfasst auch alle kleineren
Kategorien (z. B. CAT I zur Messung von
Signal- und Steuerspannungen).
CAT III
Messkategorie
III
erlaubt
die
Nutzung
des Geräts für Messungen innerhalb von
Gebäudeinstallationen (z. B. Netzsteckdosen
oder Unterverteilungen). Diese Kategorie
umfasst auch alle kleineren Kategorien (z. B.
CAT II zur Messung an Elektrogeräten). Der
Messbetrieb in CAT III ist nur mit Messspitzen
mit einer maximalen freien Kontaktlänge
von 4 mm bzw. mit Abdeckkappen über den
Messspitzen zulässig.
3. Bestimmungsgemäße Verwendung
Bei diesem Produkt handelt es sich um ein Digital-Multimeter (DMM), bei dem die Messwerte auf einem digitalen
Display angezeigt werden. Das DMM ist für den Einsatz an professionellen, industriellen und von Heimwerkern
eingerichteten Stromkreisen vorgesehen, die der Messkategorie CAT III oder einer kleineren Kategorie zuzuordnen
sind. Das Gerät ist ausschließlich für den Innengebrauch bestimmt. Kontakt mit Feuchtigkeit muss unbedingt
vermieden werden.
Aus Sicherheits- und Zulassungsgründen dürfen Sie das Produkt nicht umbauen und/oder verändern. Sollten Sie
das Produkt für andere als die zuvor beschriebenen Zwecke verwenden, kann das Produkt beschädigt werden. Eine
unsachgemäße Verwendung kann außerdem zu Gefahren wie Kurzschlüsse, Brände oder elektrischen Schlägen
führen. Lesen Sie sich die Bedienungsanleitung sorgfältig durch und bewahren Sie sie sicher auf. Reichen Sie das
Produkt nur zusammen mit der Bedienungsanleitung an Dritte weiter.
Alle enthaltenen Firmennamen und Produktbezeichnungen sind Warenzeichen der jeweiligen Inhaber. Alle Rechte
vorbehalten.
4. Lieferumfang
• Digital-Multimeter
• Messleitungen (paarweise)
• Temperaturfühler mit Punktkontakt
• 9-V-Blockbatterie
• Sicherheitshinweise
• Bedienungsanleitung (auf CD-ROM)
5. Aktuelle Bedienungsanleitungen
Laden Sie aktuelle Bedienungsanleitungen über den Link www.conrad.com/downloads herunter
oder scannen Sie den abgebildeten QR-Code. Befolgen Sie die Anweisungen auf der Webseite.
6. Merkmale und Funktionen
• Messung von AC-/DC-Spannung
• Messung von AC-/DC-Strom bis 10 A.
• Tastverhältnis
• Diodentest
• Symbol für den akustischen Durchgangsprüfer
• HOLD-Funktion
• Abschaltautomatik.
• Display mit automatischer Hintergrundbeleuchtung
• Anzeige des Spitzenwerts (PEAK)
• 6000 Counts
• True RMS
• Automatischer Messbereich
• 600-V-Hochleistungssicherungen
• Messkategorie CAT III, 600 V
Lesen Sie sich die Bedienungsanleitung sorgfältig durch und beachten Sie insbesondere
die Sicherheitshinweise. Sollten Sie die in dieser Bedienungsanleitung aufgeführten
Sicherheitshinweise und Informationen für einen ordnungsgemäßen Gebrauch nicht beachten,
übernehmen wir keine Haftung für daraus resultierende Personen- oder Sachschäden. Darüber
hinaus erlischt in solchen Fällen die Gewährleistung/Garantie.
a) Allgemeines
• Das Produkt ist kein Spielzeug. Halten Sie es von Kindern und Haustieren fern.
• Lassen Sie das Verpackungsmaterial nicht achtlos liegen. Dieses könnte andernfalls für Kinder zu
einem gefährlichen Spielzeug werden.
• Schützen Sie das Produkt vor extremen Temperaturen, direkter Sonneneinstrahlung, starken
Erschütterungen, hoher Feuchtigkeit, Nässe, brennbaren Gasen, Dämpfen und Lösungsmitteln.
• Setzen Sie das Produkt keiner mechanischen Beanspruchung aus.
• Sollte kein sicherer Betrieb mehr möglich sein, nehmen Sie das Produkt außer Betrieb und schützen
Sie es vor unbeabsichtigter Verwendung. Der sichere Betrieb ist nicht mehr gewährleistet, wenn das
Produkt
- sichtbare Schäden aufweist,
- nicht mehr ordnungsgemäß funktioniert,
- über einen längeren Zeitraum unter ungünstigen Umgebungsbedingungen gelagert wurde oder
- erheblichen Transportbelastungen ausgesetzt wurde.
• Gehen Sie stets vorsichtig mit dem Produkt um. Stöße, Schläge oder sogar das Herunterfallen aus
geringer Höhe können das Produkt beschädigen.
• Wenden Sie sich an eine Fachkraft, sollten Sie Zweifel in Bezug auf die Arbeitsweise, die Sicherheit
oder den Anschluss des Geräts haben.
• Lassen Sie Wartungs-, Änderungs- und Reparaturarbeiten ausschließlich von einer Fachkraft bzw.
einer zugelassenen Fachwerkstatt ausführen.
• Sollten Sie noch Fragen haben, die in dieser Bedienungsanleitung nicht beantwortet wurden, wenden
Sie sich an unseren technischen Kundendienst oder anderes Fachpersonal.
• In gewerblichen Einrichtungen sind die Unfallverhütungsvorschriften des Verbandes der gewerblichen
Berufsgenossenschaften für elektrische Anlagen und Betriebsmittel zu beachten.
• In Schulen, Ausbildungsstätten, Computer- oder Selbsthilfewerkstätten muss der Umgang mit
Messgeräten durch geschultes Personal in verantwortungsvoller Weise überwacht werden.
b) Angeschlossene Geräte
• Beachten Sie stets auch die Sicherheits- und Bedienhinweise der übrigen Geräte, die an dieses Produkt
angeschlossen sind.
• Eine defekte Sicherung ist durch eine baugleiche neue Sicherung zu ersetzen. Das Reparieren oder
Überbrücken einer defekten Sicherung ist nicht gestattet, da dies einen Brand verursachen oder einen
tödlichen elektrischen Schlag nach sich ziehen könnte.
d) Batterien/Akkus
• Achten Sie beim Einlegen der Batterie/des Akkus auf die richtige Polung.
• Entfernen Sie die Batterie / den Akku, wenn Sie das Gerät längere Zeit nicht verwenden, um
Beschädigungen durch Auslaufen zu vermeiden. Auslaufende oder beschädigte Batterien/Akkus
können bei Hautkontakt Säureverätzungen hervorrufen. Beim Umgang mit beschädigten Batterien/
Akkus sollten Sie daher Schutzhandschuhe tragen.
• Bewahren Sie Batterien/Akkus außerhalb der Reichweite von Kindern auf. Lassen Sie Batterien / Akkus
nicht frei herumliegen, da diese von Kindern oder Haustieren verschluckt werden könnten.
• Alle Batterien/Akkus sollten zum gleichen Zeitpunkt ersetzt werden. Das Mischen von alten und neuen
Batterien/Akkus im Gerät kann zum Auslaufen der Batterien/Akkus und zur Beschädigung des Geräts
führen.
• Nehmen Sie keine Batterien / Akkus auseinander, schließen Sie sie nicht kurz und werfen Sie sie nicht
ins�Feuer.�Versuchen�Sie�niemals,�nicht�aufladbare�Batterien�aufzuladen.�Es�besteht�Explosionsgefahr!
e) Multimeter
• Nehmen Sie das das Messgerät niemals unmittelbar nachdem es von einer kalten in eine warme
Umgebung gebracht wurde in Betrieb. Das dabei entstehende Kondenswasser kann zu irreparablen
Schäden am Produkt führen. Lassen Sie das Produkt deshalb stets zuerst auf Zimmertemperatur
kommen.
• Vergewissern Sie sich vor jeder Messung, dass das Multimeter auf die richtige Funktion eingestellt ist.
• Um einen elektrischen Schlag zu vermeiden, sollten Sie während der Messung weder direkt noch
indirekt mit den Anschlüssen/Messpunkten in Berührung kommen. Überprüfen Sie das Messgerät
vor jeder Messung auf Beschädigungen. Führen Sie auf keinen Fall Messungen durch, wenn die
Schutzisolierung beschädigt (eingerissen, abgerissen usw.) ist.
• Sehen Sie von der Verwendung während eines Gewitters unbedingt ab.
• Verwenden Sie das Produkt nicht in unmittelbarer Nähe von starken magnetischen oder
elektromagnetischen Feldern, Sendeantennen oder HF-Generatoren. Messergebnisse könnten
andernfalls erheblich beeinträchtigt werden.
• Sobald die Anzeige für eine geringe Ladekapazität der Batterie/des Akkus erscheint, sollten Sie
die� Batterie� ersetzen� bzw.� den�Akku� wieder� aufladen,� um� sicherzustellen,� dass� Sie� stets� genaue�
Messergebnisse erhalten.
• Beachten Sie die Angaben, die sich neben den Warnschildern
an den Anschlüssen für die
Messleitungen� befinden.� Die� gemessene� Spannung� oder� der�
gemessene Strom darf die
vermerkten Werte nicht überschreiten!
• Verwenden Sie das Messgerät unter keinen Umständen bei geöffnetem Gehäuse. !LEBENSGEFAHR!
• Die Kabel der Messspitzen sind in einer Art und Weise gefertigt, dass sich ihr Verschleiß deutlich
erkennen lässt. Bei Beschädigung wird eine zweite Isolierschicht in einer anderen Farbe sichtbar. Tritt
dieser Fall ein, ist die Verwendung des Messzubehörs nicht mehr gestattet und für einen entsprechenden
Ersatz zu sorgen.
• Achten Sie während der Messung darauf, die Messspitzen
ausschließlich�an�den�gekennzeichneten�Griffflächen�zu�umfassen.
• Bei Verwendung der Messspitzen ohne Abdeckkappen dürfen
Messungen zwischen dem Messgerät und dem Erdpotential nicht
oberhalb der Messkategorie CAT II durchgeführt werden.
• Bei Messungen in der Messkategorie CAT III. dürfen die Messspitzen
nur mit daran angebrachten Abdeckkappen (max. 4 mm freie Kontaktlänge) verwendet werden, um
unbeabsichtigte Kurzschlüsse während der Messung zu vermeiden. Die Abdeckkappen sind im
Lieferumfang enthalten.
• Die Messspitzen müssen bei jeder Änderung der Messfunktion vom zu messenden Objekt getrennt
werden.
• Die Spannung zwischen den Anschlusspunkten des Messgeräts und dem Erdpotential darf 600 V (DC/
AC) in CAT III nicht überschreiten.
• Lebensgefahr durch einen elektrischen Schlag! Seien Sie besonders vorsichtig, wenn Sie mit Wechsel-
oder Gleichspannungen von über 33 V bzw. 70 V arbeiten!
8. Bedienelemente und Komponenten
a) Übersicht
0
9
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
OFF
LoZ
V
LPF
%
F
C
Hz
Hz
Hz
Hz
Hz
Hz
HOLD/MAX MIN
RANGE
SEL/PEAK
C
D
E
G
J
K
H
I
A
B
F
A 10 A max-Buchse
B Taste RANGE
C Taste SEL/PEAK
D Sensor für automatische Hintergrundbeleuchtung
E Display
F Taste HOLD/MAX MIN
G Funktionswahlschalter
H
-Buchse
I COM-Buchse
J Batterie-/Akkufachabdeckung
K Ausklappbarer Standfuß
• Mit dem Wahlschalter wählen Sie zwischen den
Funktionen.
• Die Option „Auto“ für die automatische Festlegung
des Messbereichs ist für die meisten der verfügbaren
Messfunktionen aktiviert.
• Einige Funktionen sind mit Unterfunktionen belegt, die
rot gekennzeichnet sind und durch Drücken der Taste
SEL/PEAK verwendet werden können.
• Bringen Sie de Funktionswahlschalter bei Nichtgebrauch
stets in die Stellung „OFF“.
Funktion
Beschreibung
V
, V
, mV
Messung von AC-/DC-Spannung
Ω
Messung des Widerstands
Diodentest
Durchgangsprüfung
Messung der Kapazität
Hz
Messung der Frequenz
%
Messung des Tastverhältnisses
°C/°F
Messung der Temperatur
µA
, mA
, A
Messung von AC-/DC-Strom und Frequenz
LPF V
Messung�von�Wechselspannung�mit�Tiefpassfilter
LoZ V
Messung von Wechselspannung mit niedriger Impedanz
OFF
Ausschalten
9. Display und Symbole
CF
C
%
LoZ
LoZ
LoZ
P-MAX P-MIN
LO
Symbol
Beschreibung
Niedrige Batterie- bzw. Akkukapazität
Abschaltautomatik
Auto
Automatischer Messbereich
Messung�mit�Tiefpassfilter
LoZ
Messung mit niedriger Impedanz
P-MAX/P-MIN
Messung der Spitzenwerte
MAX/MIN
Größter/kleinster Messwert
Messwert wird vorübergehend dauerhaft angezeigt
Hochspannung
AC
Wechselspannung erkannt
DC
Gleichspannung erkannt
mV, V
Einheiten der elektrischen Spannung: Millivolt, Volt
µA, mA, A
Einheiten der elektrischen Stromstärke: Mikroampere, Milliampere, Ampere
Ω, kΩ, MΩ
Einheiten des elektrischen Widerstands: Ohm, Kiloohm, Megaohm
nF, µF, mF
Einheiten der elektrischen Kapazität: Nanofarad, Mikrofarad, Millifarad
Hz, kHz, Mhz
Einheiten der Frequenz: Hertz, Kilohertz, Megahertz
%
Messung des Tastverhältnisses
OL
Keine Kontinuität (Schaltung unterbrochen) oder Widerstand übersteigt
Höchstwert.
10. Einsetzen/Ersetzen der Batterie bzw. des Akkus
Schalten Sie vor dem Öffnen der hinteren
Abdeckung die Stromversorgung zur Schaltung
aus und trennen Sie die Messleitungen sowohl
von den Eingangsanschlüssen als auch von der
Schaltung.
1. Beträgt�die�Spannung�der�Batterie/des�Akkus�≤�6�V�±�
0,2 V, wird das Symbol
für eine geringe Ladekapazität
der Batterie/des Akkus im Display angezeigt.
2. Bringen Sie daraufhin den Funktionswahlschalter in die
Stellung „OFF“ und entfernen Sie die Messleitungen von
den Eingangsanschlüssen.
3. Anschließend können Sie die Schraube herausdrehen,
das Batterie-/Akkufach sicher entfernen und die Batterie
austauschen�bzw.�den�Akku�aufladen.
11. Inbetriebnahme und Verwendung
Ersetzen Sie die Batterie durch eine neue bzw. laden Sie den Akku wieder auf, sobald das Symbol
für einen
niedrigen Batterie-/Akkustand eingeblendet wird. Beachten Sie die Angaben neben den Warnschildern
, die
sich�neben�den�Anschlüssen�für�die�Messleitungen�des�DMM�befinden.�Die�gemessene�Spannung�oder�der�
gemessene Strom darf die vermerkten Werte nicht überschreiten!
Vergewissern Sie sich, dass das DMM ordnungsgemäß funktioniert, indem Sie es an einer Ihnen bekannten
Spannungsquelle testen.
Um unverfälschte Messergebnisse zu erhalten, sollten Sie stets sicherzustellen, dass sowohl die
Messspitzen�als�auch�sämtliche�Kontaktflächen�frei�von�Verunreinigungen�oder�anderweitigen�Rückständen�
sind.
a) Einschalten
• Einschalten: Bringen Sie den Funktionswahlschalter in die Stellung der gewünschten Messfunktion.
• Ausschalten: Bringen Sie den Funktionswahlschalter in die Stellung „OFF“. Schalten Sie das Messgerät bei
Nichtgebrauch immer aus.
b) Messung von AC-/DC-Spannung
�
�Die�Eingangsimpedanz�beträgt�etwa�10�MΩ�und�führt�somit�nicht�zu�einer�nennenswerten�Belastung�der�
Schaltung.
1. Bringen Sie zunächst den Funktionswahlschalter in die entsprechende Stellung.
• Bei der Messung von Gleichspannung (V
) wird „DC“ im Display angezeigt.
- Mit einem Druck auf die Taste RANGE wechseln
Sie zwischen den Messbereichen (erkennbar an der
Verschiebung der Dezimalstelle).
• Bei der Messung von Wechselspannung (V
) wird „AC“ im
Display angezeigt.
- Mit einem Druck auf die Taste RANGE wechseln
Sie zwischen den Messbereichen (erkennbar an der
Verschiebung der Dezimalstelle).
2. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss
angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss
anzuschließen.
3. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen in der Schaltung an.
- Rot: Pluspol „+“.
- Schwarz: Minuspol „-“.
4. Die Spannungswerte können jetzt vom Display abgelesen werden.
- Messung von Gleichspannungen (V
): Erscheint ein Minuszeichen „-“ vor dem Wert, ist die gemessene
Spannung negativ (oder die Messleitungen sind vertauscht).
- Bei der Messung von Wechselspannungen erhalten Sie stets die tatsächlichen Effektivwerte.
Liegen die Messwerte außerhalb des Messbereichs (>600 V), werden Sie durch einen Signalton darauf
hingewiesen.
5. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
c) Messung von AC-Spannung mit niedriger Impedanz (LoZ)
Die LoZ-Messfunktion ermöglicht das Messen von Wechselspannungen „AC“ mit niedriger Impedanz (etwa
300�kΩ).�Durch�den�geringeren�Innenwiderstand�des�Messgeräts�werden�Messabweichungen,�wie�Sie�z.�B.�bei�
Phantomspannungen auftreten, reduziert.
� Die�Eingangsimpedanz�beträgt�etwa�300�MΩ�und�führt�somit�zu�einer�geringen�Belastung�der�Schaltung.�
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung „LoZ V
“.
2. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss anzuschließen.
3. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen in der Schaltung an.
- Rot: Pluspol „+“.
- Schwarz: Minuspol „-“.
4. Die Spannungswerte können jetzt vom Display abgelesen werden.
- Bei dem angezeigten Spannungswert handelt es sich um den tatsächlichen Effektivwert.
- Warten Sie drei Minuten lang, bevor Sie eine weitere Messung durchführen.
5. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
d) Messung des Widerstands (Ω)
Stellen Sie sicher, dass alle Schaltungsteile, Schaltkreise, Komponenten und anderen Messobjekte von
der Spannungsversorgung getrennt und vollständig entladen sind.
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung „
“.
2. Drücken Sie viermal hintereinander auf die SEL-Taste, um die Funktion für die Messung des Widerstands
auszuwählen. Im Display erscheint daraufhin das Symbol „Ω“.
3. Mit einem Druck auf die Taste RANGE wechseln Sie zwischen den Messbereichen (erkennbar an der Verschiebung
der Dezimalstelle).
4. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss anzuschließen.
5. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen in der Schaltung an.
- Rot: Pluspol „+“.
- Schwarz: Minuspol „-“.
Prüfen Sie die Leitungen auf Durchgang, indem Sie die beiden Messleitungen miteinander verbinden.
Der�Impedanzwert�sollte�≤�0,5�Ω�(Eigenimpedanz�der�Messleitungen)�betragen.�Beträgt�der�Wert�≥�0,5�
Ω,�überprüfen�Sie�die�Verbindungen�zwischen�Anschlüssen�und�Messleitungen�und�inspizieren�beide�auf�
mögliche Schäden.
6. Die Spannungswerte können jetzt vom Display abgelesen werden.
- Erscheint „OL“ im Display, wurde der maximale Messbereich überschritten oder die Schaltung ist unterbrochen.
- Bei der Messung hoher Widerstände ist es ganz normal, dass einige Sekunden vergehen, bis sich die
Messwerte stabilisiert haben.
7. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
e) Durchgangsprüfung ( )
Stellen Sie sicher, dass alle Schaltungsteile, Schaltkreise, Komponenten und anderen Messobjekte von
der Spannungsversorgung getrennt und vollständig entladen sind.
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung „
“.
2. Drücken Sie dreimal hintereinander auf die SEL-Taste, um die Funktion für die Durchgangsprüfung auszuwählen.
Im Display erscheint daraufhin das Symbol „Ω
“.
3. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss anzuschließen.
4. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen in der Schaltung an.
5. Bei�einem�Widerstand�von�≤�30�Ω�werden�Sie�durch�einen�Signalton�darauf�hingewiesen,�dass�die�Messpunkte�
elektrisch miteinander verbunden sind.
- Widerstände�von�≤�600�Ω�entsprechen�hierbei�dem�zulässigen�Messbereich.
- Erscheint „OL“ im Display, wurde der maximale Messbereich überschritten oder die Schaltung ist unterbrochen.
6. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
f) Diodentest (
)
Stellen Sie sicher, dass alle Schaltungsteile, Schaltkreise, Komponenten und anderen Messobjekte von
der Spannungsversorgung getrennt und vollständig entladen sind.
Das Gerät erzeugt eine Testspannung von etwa 3 V.
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung „
“.
2. Drücken Sie zweimal auf die SEL-Taste, um die Funktion für den Diodentest auszuwählen. Im Display erscheint
daraufhin das Symbol „
“.
3. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss anzuschließen.
4. Prüfen Sie die Leitungen auf Durchgang, indem Sie die beiden Messleitungen miteinander verbinden. Hierbei
sollte Ihnen ein Spannungswert von 0,000 V angezeigt werden.
5. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen der Diode an.
- Erscheint „OL“ im Display, wurde die Polung vertauscht oder die Schaltung weist eine Unterbrechung auf.
- Der in Durchlassrichtung gemessene Spannungsabfall beträgt in etwa 500 – 800 mV.
6. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
g) Messung der Kapazität
Stellen Sie sicher, dass alle Schaltungsteile, Schaltkreise, Komponenten und anderen Messobjekte von
der Spannungsversorgung getrennt und vollständig entladen sind.
Beachten Sie bei Elektrolytkondensatoren unbedingt die Polarität.
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung „
“.
2. Drücken Sie einmal kurz auf die SEL-Taste, um die Funktion für die Messung der Kapazität auszuwählen. Im
Display erscheint daraufhin das Symbol „nF“ oder die Kapazität.
3. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss anzuschließen.
4. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen des Kondensators an.
- Beachten Sie bei Elektrolytkondensatoren stets die Polarität.
- Erscheint „OL“ im Display, wurde die Polung vertauscht oder die Schaltung weist einen Kurzschluss auf.
- Warten Sie einen Moment, bis sich der angezeigte Wert stabilisiert hat. Bei der Messung von Widerständen
>40 µF nimmt dies in der Regel einige Sekunden in Anspruch.
5. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
h) Messung der Frequenz (>10 Hz) / des Tastverhältnisses (%)
Diese Messfunktion ist nicht zur Messung von Netzstrom geeignet!
Das DMM kann zur Messung und Anzeige der Anzahl von Schwingungsperioden bis 1 MHz verwendet werden.
Die maximale Eingangsamplitude beträgt 30 Veff.
Beachten Sie die in den technischen Daten aufgeführten zulässigen Eingangsfrequenzen.
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung „Hz%“. Im Display erscheint daraufhin das
Einheitenzeichen „Hz“.
2. Drücken Sie einmal kurz auf die SEL-Taste, um zwischen den Funktionen für die Messung der Frequenz „Hz“ und
des Tastverhältnisses „%“ zu wählen.
Messung der Frequenz: Mit einem Druck auf die Taste RANGE wechseln Sie zwischen den Messbereichen
(erkennbar an der Verschiebung der Dezimalstelle).
3. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM-Anschluss anzuschließen.
4. Schließen Sie dann die Messspitzen an die richtigen Prüfstellen in der Schaltung an.
Messung des Tastverhältnisses: Die Schwingungsdauer der positiven Halbwelle wird in Prozent angezeigt.
Bei einem Wert von 50 %, handelt es sich um einen sinusförmigen Verlauf der Kurve.
5. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
i) Messung der Temperatur
Achten Sie darauf, dass der Temperaturfühler nicht nass
wird!
1. Bringen Sie zunächst den Funktionswahlschalter in die Stellung
„°C°F“.
2. Drücken Sie einmal kurz auf die SEL-Taste, um zwischen den
verfügbaren Temperatureinheiten umzuschalten. Im Display
erscheint daraufhin „°C“ bzw. „°F“.
3. Schließen Sie nun das Thermoelement Typ K an die Anschlüsse
an.
- Der Leiter „TEMP +“ muss an den
-Anschluss
angeschlossen werden.
- Der Leiter „COM -“ ist an den COM-Anschluss anzuschließen.
4. Messen Sie dann die Temperatur an der Messspitze des Fühlers.
- Beim Einschalten des DMM erscheint zunächst „OL“ im Display.
- Die gemessene Temperatur muss <400 °C / <752 °F (°F = °C × 1,8 + 32) betragen.
5. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät und bringen Sie den Funktionswahlschalter
in die Stellung „OFF“.
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
-
+
j) Messung des Stroms / der Frequenz (40 – 400 Hz)
Diese Messfunktion ist zur Messung von Netzstrom geeignet.
Schalten Sie stets zuerst die Stromversorgung der Schaltung aus, bevor Sie das DMM zur Messung in
Reihe daran anschließen, um mögliche elektrische Schläge, Brände oder Verletzungen zu vermeiden.
Sollte Ihnen der Messbereich des zu messenden Stroms unbekannt sein, beginnen Sie immer mit dem
höchsten Messbereich und wechseln bei Bedarf in die darunter liegenden Bereiche.
Beachten Sie, dass sich in den Eingangsanschlüssen „10A max“ und „mA μA“ jeweils eine Sicherung
befindet.�Schließen�Sie�die�Messleitungen�daher�nicht�an�Parallelschaltungen�an.
Liegen die Messwerte außerhalb des Messbereichs (>10 A), werden Sie durch einen Signalton darauf
hingewiesen.
Messungen an Schaltungen, die eine Stromstärke von >5 A aufweisen, dürfen nur für max. 30 Sekunden
und in Abständen von 15 Minuten durchgeführt werden.
1. Bringen Sie den Funktionswahlschalter in die Stellung µA
, mA
oder A
. Im Display erscheint daraufhin die
entsprechende Messeinheit.
2. Drücken Sie einmal kurz auf die SEL-Taste, um zwischen den Funktionen für die Messung des Gleichstroms „DC“,
des Wechselstroms „AC“ oder der Frequenz „Hz“ zu wählen.
3. Schließen Sie nun die Messleitungen an die Anschlüsse an.
- Die rote Messleitung muss an den
-Anschluss angeschlossen werden.
- Die schwarze Messleitung ist an den COM- oder den 10A max-Anschluss anzuschließen.
4. Schließen Sie dann die Messspitzen in Reihe an die Schaltung an.
5. Die Werte können jetzt vom Display abgelesen werden.
- Gleichstrom: Die Polarität wird zusammen mit dem gemessenen Wert angezeigt.
- Wechselstrom: Bei der Messung von Wechselstrom erhalten Sie stets die tatsächlichen Effektivwerte.
- Frequenz:�Der�Messbereich�beträgt�40�–�400�Hz�(Eingangsamplitude�≥�Bereich�×�50�%).
6. Trennen Sie nach Abschluss der Messung die Messleitungen vom Gerät, trennen Sie die Schaltung von der
Stromversorgung und bringen Sie den Funktionswahlschalter in die Stellung „OFF“.
Kurzer Tastendruck = weniger als zwei Sekunden.
Langer Tastendruck = mehr als zwei Sekunden gedrückt halten.
a) Zugriff auf Unterfunktionen
Die� meisten� der� Messfunktionen,� deren� Beschriftung� Sie� um� den� Funktionswahlschalter� herum� finden,� sind� mit�
Unterfunktionen belegt und rot hervorgehoben. Um zwischen den einzelnen Unterfunktionen umzuschalten, drücken
Sie wiederholt kurz auf die SEL-Taste.
b) Messbereich
Durch Drücken der Taste RANGE legt das DMM nicht mehr automatisch den Messbereich fest und ermöglicht es
Ihnen, den Bereich manuell einzustellen.
Dieser Modus steht Ihnen jedoch nur bei den folgenden Messfunktionen zur Verfügung: V
, V
, Ω, Hz, µA
, mA
und A
.
• Wechsel in den manuellen Betrieb: Drücken Sie einmal kurz auf die RANGE-Taste.
- Im Display erscheint daraufhin „Auto“.
- Mit einem Druck auf die Taste RANGE wechseln Sie zwischen den Messbereichen (erkennbar an der
Verschiebung der Dezimalstelle).
• Beenden des manuellen Betriebs: Sobald Sie die RANGE-Taste gedrückt halten oder den Funktionswahlschalter
in eine andere Stellung bringen, wird der manuelle Betrieb beendet und „Auto“ erscheint wieder im Display.
c) HOLD-Funktion
Mit dieser Funktion können Sie den angezeigten Wert „einfrieren“, d.h. er wird länger auf dem Display angezeigt, so
dass Sie mehr Zeit zum Ablesen oder Protokollieren haben.
Stellen Sie beim Prüfen stromführender bzw. unter Spannung stehender Leitungen sicher, dass diese
Funktion vor Beginn der Messung deaktiviert ist. Andernfalls lässt sich der tatsächliche Wert nicht
feststellen.
• Mit einem kurzen Druck auf die HOLD-Taste aktivieren bzw. deaktivieren Sie die Funktion.
• Ist die HOLD-Funktion aktiv, werden Sie durch das
-Symbol im Display darauf hingewiesen.
• Mit dieser Funktion haben Sie die Möglichkeit, schnellere Signalereignisse als mit der normalen Min/Max-Funktion
zu erfassen. So können selbst Eingangsänderungen, die gerade einmal eine Millisekunde oder länger dauern,
zuverlässig protokolliert werden.
• Dieser Modus steht Ihnen jedoch nur bei den folgenden Messfunktionen zur Verfügung: V
, mV
, µA
, mA
und A
.
• Um den Modus zur Erfassung von Spitzenwerten zu aktivieren bzw. zu deaktivieren, halten Sie die PEAK-Taste
gedrückt.
• Um zwischen den Werten für „P-MAX“ und „P-MIN“ umzuschalten, genügt ein kurzer Druck auf die PEAK-Taste.
e) Höchst-/Tiefstwerte
Diese Funktion ermöglicht das Speichern und Anzeigen von Höchst- oder Tiefstwerten, die sich aus einer Messreihe
ergeben. Die automatische Festlegung des Messbereichs ist in diesem Modus deaktiviert.
• Dieser Modus steht Ihnen jedoch nur bei den folgenden Messfunktionen zur Verfügung: LoZV
, LPFV
, V
, V
, mV
, Ω, µA
, mA
, A
und °C/°F.
• Wählen Sie vor der Nutzung dieser Funktion stets zuerst den richtigen Messbereich, um sicherzustellen, dass die
MAX-/MIN-Messwerte den Messbereich nicht über- bzw. unterschreiten.
• Bei den erfassten Werten handelt es sich um jene, die seit dem Zeitpunkt der Aktivierung des Modus aufgezeichnet
wurden. Eingangsänderungen, die mehr als 100 Millisekunden dauern, werden zuverlässig protokolliert.
• Um den Modus zur Anzeige und Speicherung der Höchst- und Tiefstwerte zu aktivieren bzw. zu deaktivieren,
halten Sie die MAX MIN-Taste gedrückt.
• Drücken Sie einmal kurz auf die MAX MIN-Taste, um zwischen den Messwerten umzuschalten.
- Höchstwert: Im Display wird MAX angezeigt.
- Tiefstwert: Im Display wird MIN angezeigt.
Bei der Abschaltautomatik handelt es sich um eine effektive Energiesparfunktion. Bei Aktivierung versetzt sich das
Gerät automatisch in den Ruhezustand, wenn etwa 15 Minuten lang keine Betätigung der Tasten erfolgt. Drücken
Sie eine beliebige Taste oder verwenden Sie den Funktionswahlschalter, um das Gerät wieder in Betrieb zu nehmen.
1Deaktivierung der Abschaltautomatik
1. Bringen Sie den Funktionswahlschalter in die Stellung „OFF“.
2. Bringen Sie nun den Funktionswahlschalter, während Sie die Taste SEL/PEAK gedrückt halten, in eine beliebige
andere Stellung.
3. Das
-Symbol wird daraufhin ausgeblendet.
2Aktivierung der Abschaltautomatik
• Starten Sie dazu das Gerät neu, indem Sie den Funktionswahlschalter in die Stellung „OFF“ und anschließend in
die Stellung „ON“ bringen.
• Das
-Symbol erscheint daraufhin wieder im Display.
g) Automatische Hintergrundbeleuchtung
Fällt die Umgebungslichtstärke unter einen bestimmten Schwellenwert, schaltet sich die Hintergrundbeleuchtung
automatisch EIN (Dauer: 30 Sek.). Bei ausreichender Helligkeit schaltet sich die Hintergrundbeleuchtung automatisch
wieder AUS.
13. Austauschen der Sicherung
Verwenden Sie das Messgerät unter keinen Umständen bei geöffnetem Gehäuse. !LEBENSGEFAHR!
1. Bringen
Sie
zunächst
den
Funktionswahlschalter in die Stellung „OFF“.
2. Trennen Sie die Messleitungen von den
Eingangsanschlüssen.
3. Drehen Sie nun die Schraube am Batterie-/
Akkufach heraus und entfernen Sie die
Abdeckung.
4. Drehen Sie dann die Schrauben der
Gehäuserückseite heraus.
5. Ersetzen Sie die defekte Sicherung durch
eine neue Sicherung desselben Typs und
derselben� Spezifikationen.� Die� genauen�
Angaben� dazu� finden� Sie� im� Abschnitt�
„Technische Daten“.
6. Bringen
Sie
anschließend
die
Gehäuserückseite und die Abdeckung
sicher wieder an.
14. Problembehandlung
Problem
Mögliche Ursache
Behebung
Das DMM lässt sich nicht
einschalten.
Die Kapazität der Batterie oder
des Akkus ist aufgebraucht.
Ersetzen Sie die Batterie durch eine neue
bzw. laden Sie den Akku wieder auf.
Es lässt sich keine Ände-
rung der Werte feststellen.
Haben Sie möglicherweise die
falsche Messfunktion (AC/DC)
aktiviert?
Überprüfen Sie das Display (AC/DC) und
wechseln Sie ggf. die Funktion.
Verwenden Sie die falschen
Messleitungen?
Überprüfen Sie die Anschlussbelegung bzw.
den Anschluss der Messleitungen.
Ist die HOLD-Funktion aktiv?
Deaktivieren Sie die HOLD-Funktion.
Es ist keine Messung im
Messbereich A möglich.
Ist die Sicherung des A max-
Anschlusses defekt?
Überprüfen Sie die 10 A F2-Sicherung des
Anschlusses.
Es ist keine Messung
im Messbereich mA/µA
möglich.
Ist die Sicherung des mA/µA-
Anschlusses defekt?
Überprüfen Sie die 0,6 A F1-Sicherung des
Anschlusses.
15. Wartung und Reinigung
a) Reinigung
Verwenden Sie keine aggressiven Reinigungsmittel, Alkohol oder andere chemische Lösungsmittel, da
diese zu Schäden am Gehäuse und zu Fehlfunktionen führen können.
• Trennen Sie das Produkt vor jeder Reinigung von der Stromversorgung.
• Verwenden Sie zum Reinigen des Produkts ein trockenes, faserfreies Tuch.
• Sollte das Gerät eine Störung aufweisen, sehen Sie von der weiteren Verwendung unbedingt ab und schicken
Sie�es�zur�Wartung�ein.�Wartungs-�und�Servicearbeiten�dürfen�nur�von�qualifiziertem�Fachpersonal�durchgeführt�
werden.
b) Wartung
• Das DMM sollte einmal jährlich kalibriert werden, damit die höchstmögliche Messgenauigkeit gewährleistet ist.
• Das DMM erfordert bis auf den Austausch der Batterie/des Akkus und der Sicherungen keinerlei Wartung durch
den Nutzer.
• Überprüfen Sie das Gerät und die Messleitungen vor jedem Einsatz auf Anzeichen von Verschleiß und
Beschädigung.
16. Konformitätserklärung (DOC)
Hiermit erklärt Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, dass dieses Produkt der Richtlinie
2014/53/EU entspricht.
Der vollständige Text der EU-Konformitätserklärung ist unter der folgenden Internetadresse verfügbar:
www.conrad.com/downloads
Wählen Sie eine Sprache durch Anklicken eines Flaggensymbols aus und geben Sie die Bestellnummer
des Produkts in das Suchfeld ein. Anschließend können Sie die EU-Konformitätserklärung im PDF-Format
herunterladen.
Elektronische Geräte sind Wertstoffe und gehören nicht in den Hausmüll. Entsorgen Sie das Produkt am
Ende seiner Lebensdauer gemäß den geltenden gesetzlichen Bestimmungen.
Entnehmen Sie evtl. eingelegte Batterien/Akkus und entsorgen Sie diese getrennt vom Produkt.
b) Batterien/Akkus
Sie als Endverbraucher sind gesetzlich (Batterieverordnung) zur Rückgabe aller gebrauchten Batterien/
Akkus�verpflichtet;�Eine�Entsorgung�im�Hausmüll�ist�untersagt.
Schadstoffhaltige Batterien/Akkus sind mit dem nebenstehenden Symbol gekennzeichnet, das auf das
Verbot der Entsorgung über den Hausmüll hinweist. Die Bezeichnungen für die enthaltenen Schwermetalle
sind: Cd = Cadmium, Hg = Quecksilber, Pb = Blei (die Bezeichnung steht auf den Batterien/Akkus z.B.
unter dem links abgebildeten Mülltonnen-Symbol).
Ihre verbrauchten Batterien/Akkus können Sie unentgeltlich bei den Sammelstellen Ihrer Gemeinde, unseren Filialen
oder überall dort abgeben, wo Batterien/Akkus verkauft werden!
Sie�erfüllen�damit�die�gesetzlichen�Verpflichtungen�und�leisten�Ihren�Beitrag�zum�Umweltschutz.
18. Technische Daten
a) Allgemeines
Spannungsversorgung .....................................9-V-Blockbatterie (6F22, NEDA 1604 oder identischer Typ)
Betriebs-/Batterielaufzeit ..................................etwa 120 Std. (bei ausgeschalteter Hintergrundbeleuchtung)
Impedanzmessung (Eingang) ...........................etwa�10�MΩ�(600�mV:�≥�1000�MΩ)
Anzeigegenauigkeit ..........................................6000 Counts (maximal darstellbare Zahl)
Aktualisierungsrate ...........................................2 – 3 Mal pro Sekunde
Temperaturmessbereich ...................................-40 bis +400 °C (-40 bis +752 °F)
Messverfahren AC ............................................True RMS
Länge der Messleitungen .................................jeweils etwa 80 cm
Anzeige für niedrigen Batterie-/Akkustand .......≤�6�V�±�0,2�V
Durchmesser des Messanschlusses ................19 mm (COM-V)
Abschaltautomatik ............................................Aktivierung nach etwa 15 Minuten
Dauer der HOLD-Funktion ................................max. 15 Minuten
Messkategorie ..................................................≤�CAT�III�(bis�600�V)
Verschmutzungsgrad ........................................2
Gleichspannung ................................................max. 600,0 V/DC
Wechselspannung ............................................max. 600,0 V/AC
Gleichstrom ......................................................max. 10,0 A/DC
Wechselstrom ...................................................max. 10,0 A/AC
Widerstand .......................................................max.�60�MΩ
Kapazität ..........................................................max. 60 mF
Betriebstemperatur ...........................................0 bis +40 °C
Lagertemperatur ...............................................-10�bis�+50˚C
Betriebs-/Lagerbedingungen ............................�0�bis�+30�˚C:�≤�75�%�rF�(nicht�kondensierend)�
+30�bis�+40�˚C:�≤�50�%�rF�(nicht�kondensierend)
Betriebshöhe ....................................................max. 2000 m über dem Meeresspiegel
Abmessungen (B x H x T): ...............................75 x 150,6 x 38 mm
Gewicht .............................................................etwa 221 g (ohne Batterie/Akku)
b) Sicherungen
F1-Sicherung .................................................... ø6 x 32 mm, 0,6 A, H600 V, FF
Schutz�des�Eingangsanschlusses�(μA,�mA)
F2-Sicherung .................................................... ø6 x 25 mm, 10 A, H600 V, FF
Schutz des Eingangsanschlusses (A)
Die Messgenauigkeit ist unter den folgenden Bedingungen ein Jahr lang garantiert:
• Umgebungstemperatur:�+3�°C�(±�5�°C),�≤�75�%�rF�(nicht�kondensierend)
• Betriebstemperatur*:�+18�bis�+28�°C�(±�1�°C)�
*Außerhalb�dieses�Temperaturbereichs�gilt�der�folgende�Temperaturkoeffizient:�+0,1�x�(angegebene�Genauigkeit)�/�°C.
Beachten Sie, dass die Messung erheblich beeinträchtigt werden kann, wenn das Gerät in einem hochfrequenten
elektromagnetischen Feld betrieben wird.
d) Messung der Kapazität
Bereich
Auflösung
Genauigkeit
6,000 nF
1 pF
±�(5�%�+�10)
60,00�nF�–�600,0�μF
10�pF�–�0,1�μF
±�(4�%�+�7)
6,000 mF – 60,00 mF
1�μF�–�10�μF
±�13�%
Überlastschutz: 600 V
e) Durchgangsprüfung ( ) und Diodentest (
)
Bereich
Auflösung
Anmerkung
0,1�Ω
• Schaltung�unterbrochen:�Widerstand�>100�Ω,�kein�Signalton.
• Schaltung mit guter Verbindung zwischen den Messpunkten: Widerstand
>30�Ω,�sich�durchgehend�wiederholende�Signaltöne.
1 mV
• Spannung bei nicht verbundenen Messleitungen: etwa 3 V
• In Durchlassrichtung gemessener Spannungsabfall bei Silizium-Dioden:
etwa 0,5 – 0,8 V
Überlastschutz: 600 V
f) Messung von Gleichspannung (DC)
Bereich
Auflösung
Genauigkeit
600,0 mV
0,1 mV
±�(0,9�%�+�4)
6,000 V
0,001 V
±�(0,6�%�+�4)
60,00 V
0,01 V
±�(0,9�%�+�4)
600,0 V
0,1 V
• Eingangsimpedanz:�≥�1000�MΩ�für�mV-Messbereich�(Kurzschluss�ermöglicht�≤�5�Kommastellen),�etwa�10�MΩ�
für die übrigen Messbereiche.
• Eingangsspannung: max. 600 V
g) Messung von Wechselspannung (AC)
Bereich
Auflösung
Genauigkeit
600,0 mV
0,1 mV
±�(1,3�%�+�5)
6,000 V
0,001 V
±�(1,0�%�+�5)
60,00 V
0,01 V
±�(1,3�%�+�4)
600,0 V
0,1 V
±�(1,3�%�+�4)
LoZ (V/AC) 600,0 V
0,1 V
±�(2,6�%�+�4)
LPF (V/AC) 600,0 V
0,1 V
±�(2,5�%�+�6)
• Eingangsimpedanz:�etwa�10�MΩ.
• Anzeige des Effektivwerts (True RMS).
• Frequenzgang: 40 – 400 Hz. LPF-Frequenzgang: 40 – 200 Hz.
• Lassen Sie das Messgerät nach Verwendung der LoZ-Funktion eine Minute lang abkühlen.
• Messgenauigkeit, garantierter Bereich: 5~100 % des Messbereichs, Kurzschluss erlaubt niederwertigste Stelle
<10.
• Der�Scheitelfaktor�einer�Wechselgröße�beträgt�≤�3,0,�wenn�er�bei�3000�Counts�gemessen�wird.�Der�Scheitelfaktor�
einer�Wechselgröße�beträgt�≤�1,5,�wenn�die�Messung�unter�Nutzung�des�Gesamtbereiches�bei�6000�Counts�erfolgt.
• Für nicht sinusförmige Wechselgrößen gilt:
- Beträgt der Scheitelfaktor 1,0 bis 2,0, muss die Genauigkeit um 4,0 % erhöht werden.
- Beträgt der Scheitelfaktor 2,0 bis 2,5, muss die Genauigkeit um 5,0 % erhöht werden.
- Beträgt der Scheitelfaktor 2,5 bis 3,0, muss die Genauigkeit um 7,0 % erhöht werden.
• Eingangsspannung: max. 600 Veff.
h) Messung des Widerstands (Ω)
Bereich
Auflösung
Genauigkeit
600,0�Ω
0,1�Ω
±�(1,3�%�+�3)
6,000�kΩ
1�Ω
±�(1,0�%�+�3)
60,00�kΩ
10�Ω
600,0�kΩ
100�Ω
6,000�MΩ
1�kΩ
±�(1,6�%�+�4)
60,00�MΩ
10�kΩ
±�(3,0�%�+�7)
Überlastschutz: 600 V
i) Messung der Frequenz / des Tastverhältnisses
Bereich
Auflösung
Genauigkeit
10,00 Hz – 1,00 MHz
0,01 Hz – 0,001 MHz
±�(0,1�%�+�6)
0,1 – 99,9 %
0,1 %
±�(3�%�+�6)
• Überlastschutz: 600 V
• Eingangsamplitude a: (DC-Niveau = 0)
≤100�kHz:�200�mVeff�≤�a�≤�30�Veff
>100�kHz�–�1�MHz:�600�mVeff�≤�a�≤�30�Veff
• Die�Messung�des�Tastverhältnisses�ist�für�Rechteckwellen�mit�Frequenzen�von�≤�10�kHz�vorgesehen.
1�Vss�≤�Eingangsamplitude�≤�30�Vss.
Frequenz�≤�1�kHz,�Tastverhältnis:�10,0�–�95,0�%
Frequenz�≤�1�kHz,�Tastverhältnis:�30,0�–�70,0�%
j) Messung von Gleichstrom (DC)
Bereich
Auflösung
Genauigkeit
μA
600,0�μA
0,1�μA
±�(1,0�%�+�4)
6000�μA
1�μA
mA
60,00 mA
10�μA
600,0 mA
0,1 mA
A
6,000 A
1 mA
±�(1,3�%�+�4)
10,00 A
10 mA
±�(1,5�%�+�6)
• Beträgt�die�Stärke�des�gemessenen�Stroms�>5�A,�beschränken�Sie�die�Dauer�der�Messung�auf�≤�30�Sekunden�
und�gewähren�Sie�dem�Gerät�eine�Ruhephase�von�≥�15�Minuten�zwischen�den�Messungen.
• Überlastschutz:
- F1-Sicherung:�μA/mA-Messbereich,�ø6�x�32�mm,�0,6�A,�H600�V,�FF(CE)
- F2-Sicherung: 10 A-Messbereich, ø6 x 25 mm, 10 A, H600 V, FF(CE)
k) Messung der Temperatur
Bereich
Auflösung
Genauigkeit
°C
-40 bis +400 °C
-40 bis +300 °C
0,1 bis 1 °C
±�(1,4�%�+�3�°C)
+300 bis +400 °C
°F
-40 bis +752 °F
-40 bis +572 °F
0,2 bis 2 °F
±�(1,4�%�+�5�°F)
+5720 bis +752 °F
• Überlastschutz: 600 V
• Das Thermoelement Typ K ist nur für die Messung von Temperaturen < +400 °C (+752 °F) geeignet.
l) Messung von Wechselstrom (AC)
Bereich
Auflösung
Genauigkeit
μA
600,0�μA
0,1�μA
±�(1,3�%�+�4)
6000�μA
1�μA
mA
60,00 mA
10�μA
600,0 mA
0,1 mA
A
6,000 A
1 mA
±�(1,6�%�+�4)
10,00 A
10 mA
±�(1,8�%�+�6)
• Beträgt�die�Stärke�des�gemessenen�Stroms�>5�A,�beschränken�Sie�die�Dauer�der�Messung�auf�≤�30�Sekunden�
und�gewähren�Sie�dem�Gerät�eine�Ruhephase�von�≥�15�Minuten�zwischen�den�Messungen.
• Anzeige des Effektivwerts (True RMS).
• Frequenzgang: 40 – 400 Hz.
• Messgenauigkeit, garantierter Bereich: 5 – 100 % des Messbereichs, Kurzschluss erlaubt niederwertigste Stelle <2.
• Der�Scheitelfaktor�einer�Wechselgröße�beträgt�≤�3,0,�wenn�er�bei�3000�Counts�gemessen�wird.�Der�Scheitelfaktor�
einer�Wechselgröße�beträgt�≤�1,5,�wenn�die�Messung�unter�Nutzung�des�Gesamtbereiches�bei�6000�Counts�erfolgt.
• Für nicht sinusförmige Wechselgrößen gilt:
- Beträgt der Scheitelfaktor 1,0 bis 2,0, muss die Genauigkeit um 4,0 % erhöht werden.
- Beträgt der Scheitelfaktor 2,0 bis 2,5, muss die Genauigkeit um 5,0% erhöht werden.
- Beträgt der Scheitelfaktor 2,5 bis 3,0, muss die Genauigkeit um 7,0% erhöht werden.
• Überlastschutz:
- F1-Sicherung:�μA/mA-Messbereich,�ø6�x�32�mm,�0,6�A,�H600�V,�FF(CE)
- F2-Sicherung: 10 A-Messbereich, ø6 x 25 mm, 10 A, H600 V, FF (CE)
Table of contents
Page
1.
Introduction ........................................................................................................................................................33
2.
Explanation of symbols ......................................................................................................................................33
3.
Intended use ......................................................................................................................................................34
4.
Delivery content .................................................................................................................................................34
5.
Up-to-date operating instructions .......................................................................................................................34
6.
Features and functions ......................................................................................................................................34
7.
Safety instructions .............................................................................................................................................35
a) General information .....................................................................................................................................35
b) Connected devices ......................................................................................................................................35
c) Fuse .............................................................................................................................................................36
d) (Rechargeable) batteries .............................................................................................................................36
e) Multimeter ....................................................................................................................................................36
f) Probes .........................................................................................................................................................37
8.
Operating elements ...........................................................................................................................................38
a) Overview ......................................................................................................................................................38
b) Dial ..............................................................................................................................................................39
9.
Display and symbols ..........................................................................................................................................40
10. Insert / replace batteries ....................................................................................................................................41
11. Operation ...........................................................................................................................................................41
a) Power ON ....................................................................................................................................................41
b) DC/AC voltage Measurement ......................................................................................................................42
c) LoZ AC voltage measurement .....................................................................................................................43
d)� Resistance�measurement�(Ω) ......................................................................................................................43
e) Continuity test (
) ......................................................................................................................................44
f) Diode test (
) ...........................................................................................................................................44
g) Capacity measurement ................................................................................................................................45
h) Frequency (>10 Hz) / duty ratio measurement (%) .....................................................................................45
i) Temperature measurement .........................................................................................................................46
j) Current measurement / Frequency (40 to 400 Hz) ......................................................................................46
12. Additional functions ............................................................................................................................................47
a) Access sub functions ...................................................................................................................................47
b) Range ..........................................................................................................................................................47
c) Hold .............................................................................................................................................................47
d) Peak ............................................................................................................................................................47
e) Maximum / Minimum ...................................................................................................................................48
f) Automatic power off .....................................................................................................................................48
g) Automatic backlight .....................................................................................................................................48
13. Replacing the Fuse ............................................................................................................................................49
14. Troubleshooting .................................................................................................................................................49
15. Cleaning and maintenance ................................................................................................................................50
a) Cleaning ......................................................................................................................................................50
b) Maintenance ................................................................................................................................................50
16. Declaration of Conformity (DOC) .......................................................................................................................50
17. Disposal .............................................................................................................................................................51
a) Product ........................................................................................................................................................51
b) (Rechargeable) batteries .............................................................................................................................51
18. Technical data ....................................................................................................................................................52
a) General ........................................................................................................................................................52
b) Fuses ...........................................................................................................................................................52
c) Measurement tolerances .............................................................................................................................53
d) Capacitance measurement ..........................................................................................................................53
e) Continuity (
) and diode (
) test ............................................................................................................53
f) DC voltage measurement ............................................................................................................................53
g) AC voltage measurement ............................................................................................................................54
h)� Resistance�measurement�(Ω) ......................................................................................................................54
i) Frequency / duty ratio measurement ...........................................................................................................55
j) DC current measurement ............................................................................................................................55
k) Temperature measurement .........................................................................................................................56
l) AC current measurement ............................................................................................................................56
Thank you for purchasing this product.
This product complies with the statutory national and European requirements.
To maintain this status and to ensure safe operation, you as the user must observe these operating instructions!
These operating instructions are part of this product. They contain important notes on commissioning and
handling. Also consider this if you pass on the product to any third party. Therefore, retain these operating
instructions for reference!
If there are any technical questions, please contact: www.conrad.com/contact
2. Explanation of symbols
The symbol with the lightning in the triangle is
used if there is a risk to your health, e.g. due to
an electric shock.
The symbol with the exclamation mark in
the triangle is used to indicate important
information in these operating instructions.
Always read this information carefully.
The arrow symbol indicates special information
and advice on operation.
This device is CE-compliant and meets
applicable European directives.
Protection class 2 (double or reinforced
insulation, protective insulation).
Earth ground
CAT I
Measuring category I for measurements on
electrical and electronic devices that are not
directly supplied with mains voltage (e.g.
battery-powered
devices,
protective
low
voltages, signal and control voltages, etc.).
CAT II
Measuring category II for measurements on
electrical and electronic devices connected to
the mains supply directly with a mains plug.
This category also covers all lower categories
(e.g. CAT I for measuring signal and control
voltages).
CAT III
Measuring category III for measuring in
building installations (e.g. outlets or sub-
distribution). This category also covers all
lower categories (e.g. CAT II for measuring
electronic devices). Measuring operation
in CAT III is only permitted with measuring
probes with a maximum free contact length of
4 mm or with cover caps above the measuring
probes.
3. Intended use
The product is intended to be used as a digital multimeter (DMM), measured values are shown on a digital display.
The DMM can be used for professional, industrial and do-it-yourself applications up to CAT III. It is intended for indoor
use only. Contact with moisture must be avoided under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use the product for purposes
other than those described above, the product may be damaged. In addition, improper use can result in short circuits,
fires,�electric�shocks�or�other�hazards.�Read�the�instructions�carefully�and�store�them�in�a�safe�place.�Make�this�
product available to third parties only together with its operating instructions.
All company names and product names are trademarks of their respective owners. All rights reserved.
4. Delivery content
• Digital multimeter
• Test leads (pair)
• Point contact temperature probe
• 9 V block battery
• Safety information
• Operating instructions (on CD-ROM)
5. Up-to-date operating instructions
Download the latest operating instructions at www.conrad.com/downloads or scan the QR code
shown. Follow the instructions on the website.
6. Features and functions
• AC / DC voltage measurement
• AC / DC current measurement up to 10 A.
• Duty cycle
• Diode test
• Acoustic continuity tester
• Hold function
• Auto power off.
• Automatic display backlight
• Peak reading (PEAK)
• 6000 counts
• True RMS
• Auto range
• 600 V high performance fuses
• CAT III 600 V measuring category
7. Safety instructions
Read the operating instructions carefully and especially observe the safety information. If you do
not follow the safety instructions and information on proper handling in this manual, we assume
no liability for any resulting personal injury or damage to property. Such cases will invalidate the
warranty/guarantee.
a) General information
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. This may become dangerous playing material
for children.
• Protect the appliance from extreme temperatures, direct sunlight, strong jolts, high humidity, moisture,
flammable�gases,�steam�and�solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and protect it from any
accidental use. Safe operation can no longer be guaranteed if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the
product.
• Consult an expert when in doubt about the operation, safety or connection of the appliance.
• Maintenance,�modifications�and�repairs�must�only�be�completed�by�a�technician�or�an�authorised�repair�
centre.
• If you have questions which remain unanswered by these operating instructions, contact our technical
support service or other technical personnel.
• In commercial institutions, the accident prevention regulations of the Employer’s Liability Insurance
Association for Electrical Systems and Operating Materials are to be observed.
• In schools, training centres, computer and self-help workshops, handling of meters must be supervised
by trained personnel in a responsible manner.
b) Connected devices
• Observe the safety and operating instructions of any other devices which are connected to the product.
d) (Rechargeable) batteries
• Correct polarity must be observed while inserting the (rechargeable) battery.
• The (rechargeable) batteries should be removed from the device if it is not used for a long period of time
to avoid damage through leaking. Leaking or damaged (rechargeable) batteries might cause acid burns
when in contact with skin, therefore use suitable protective gloves to handle corrupted (rechargeable)
batteries.
• (Rechargeable) batteries must be kept out of reach of children. Do not leave (rechargeable) batteries
lying around, as there is risk, that children or pets swallow them.
• All (rechargeable) batteries should be replaced at the same time. Mixing old and new (rechargeable)
batteries in the device can lead to (rechargeable) battery leakage and device damage.
• (Rechargeable)�batteries�must�not�be�dismantled,�short-circuited�or�thrown�into�fire.�Never�recharge�
non-rechargeable batteries. There is a risk of explosion!
e) Multimeter
• Do not switch the meter on after it has been taken from a cold to a warm environment. The condensation
that forms might destroy the device. Allow the device to reach room temperature before switching it on.
• Check that the multimeter is set to the correct function before each measurement.
• To avoid electric shock, do not touch the connections/measuring points directly or indirectly during
measurement. Check the meter for damage before each measurement. Never carry out any
measurements if the protecting insulation is defective (torn, ripped off etc.)
• Do not use the during thunderstorms.
• Never�operate�the�product�in�direct�proximity�of�strong�magnetic�or�electromagnetic�fields�or�transmitter�
aerials or HF generators. This could affect measurement.
• For accurate measurements, replace the battery when the low battery symbol appears on the display.
• Pay attention to the information besides the warning signs
at the test lead terminals. The measured
voltage or current must not exceed the values shown!
• Never operate the meter when the case is open. !DANGER TO LIFE!
• The probe cables have a wear indicator. When damaged, a second insulation layer in a different colour
becomes visible. The measuring accessories must no longer be used and must be replaced.
• During measuring, do not grip beyond the grip range markings indicated on the measuring probes.
• When using the measuring probes without cover caps, measurements
between the meter and the earth potential must not be performed
above the measuring category CAT II.
• When measuring in the measuring category CAT III. Measuring
probes with cover caps (max. 4 mm free contact length) must be
used to avoid accidental short circuits during measurement. They
are enclosed.
• The measuring probes must be removed from the measured object each time the measuring function
is changed.
• The voltage between the connection points of the meter and the earth potential must not exceed 600
V DC/AC in CAT III.
• Risk of fatal electric shock! Be careful when dealing with voltages higher than 33 V/AC or 70 V/DC.
8. Operating elements
a) Overview
0
9
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
OFF
LoZ
V
LPF
%
F
C
Hz
Hz
Hz
Hz
Hz
Hz
HOLD/MAX MIN
RANGE
SEL/PEAK
C
D
E
G
J
K
H
I
A
B
F
A 10 A max terminal
B RANGE button
C SEL/PEAK button
D Auto-backlight sensor
E Display
F HOLD/MAX MIN button
G Function dial
H
terminal
I COM terminal
J Battery compartment cover
K Fold-out stand
• Adjust the dial to choose a function.
• Automatic range selection “Auto” is active for most
measuring functions.
• Some functions have sub functions, these are marked in
red can be accessed by pressing the SEL/PEAK button.
• Always set the dial to “OFF” when not in use.
Function
Description
V
, V
, mV
AC/DC voltage measurement
Ω
Resistance measurement
Diode test
Continuity test
Capacitance measurement
Hz
Frequency measurement
%
Duty ratio measurement
°C/°F
Temperature measurement
µA
, mA
, A
AC/DC current / frequency measurement
LPF V
Low�pass�filter�measurement�for�AC�voltage
LoZ V
Low impedance measurement for AC voltage
OFF
Shutdown
9. Display and symbols
CF
C
%
LoZ
LoZ
LoZ
P-MAX P-MIN
LO
Icon
Description
Low battery
Auto power off
Auto
Auto range
Low�pass�filter�measurement
LoZ
Low impedance measurement
P-MAX/P-MIN
Peak value measurement
MAX/MIN
Maximum/Minimum measurement
Data hold
High voltage
AC
AC signal
DC
DC signal
mV, V
Voltage units: millivolt, volt
µA, mA, A
Current units: microampere, milliampere, ampere
Ω, kΩ, MΩ
Resistance units: ohm, kilo ohm, megaohm
nF, µF, mF
Capacitance units: nanofarad, microfarad, millifarad
Hz, kHz, Mhz
Frequency units: hertz, kilohertz, megahertz
%
Duty ratio measurement
OL
Non-continuity (open loop) or resistance exceeds max. range.
10. Insert / replace batteries
Before opening the rear cover, switch off the
power supply and disconnect the test leads
from the input terminals and the circuit.
1. When� the� battery� voltage� is� ≤6� V� ±0.2� V,� the� low�
battery symbol
will be displayed.
2. Turn the function dial to the “OFF” position, and
remove the test leads from the input terminals.
3. Unscrew and remove the battery cover to replace the
battery.
11. Operation
Replace the battery if the low battery warning
shows. Pay attention to the information besides the
warning signs marked on the DMM
beside the test lead terminals. The measured voltage or current
must not exceed the values shown!
Test on known voltages to verify that the DMM is functioning correctly.
For accurate measurement results, make sure the probe tips and any areas of contact are free from debris
or residue.
a) Power ON
• Turn ON: Set the function dial to the corresponding measurement function.
• Turn OFF: Set the function dial to “OFF”. Always turn the meter off when it is not in use.
b) DC/AC voltage Measurement
�
The�input�impedance�is�approximately�10�M�and�will�not�put�much�strain�on�the�circuit.
1. Set the function dial to the required setting:
• DC voltage measurement (V
), “DC” will show on the display.
- Short press RANGE to toggle through ranges (indicated by decimal position).
• AC voltage measurement (V
), “AC” will shoe on the display.
- Short press RANGE to toggle through ranges (indicated by
decimal position).
2. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
3. Connect the test lead probes to the correct test points in the
circuit:
- Red: Positive polarity “+”.
- Black: Negative polarity “-”.
4. Read the voltage values on the display.
- DC voltage measurements (V
): If a minus “-” sign appears in front of the value, the measured voltage is
negative (or the measuring lines are swapped).
- AC voltage measurements are given in true RMS.
A warning will sound when measured values are out of range >600 V.
5. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF.
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
c) LoZ AC voltage measurement
The�LoZ�measuring�function�permits�alternating�“AC”�voltage�measurements�with�low�impedance�(approx.�300�kΩ).�
The lower internal resistance of the meter reduces measurement discrepancies such as phantom voltages.
� The�input�impedance�is�approximately�300�k�and�will�put�some�strain�on�the�circuit.�
1. Set the function dial to LoZ V
.
2. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
3. Connect the test lead probes to the correct test points in the circuit:
- Red: Positive polarity “+”.
- Black: Negative polarity “-”.
4. Read the voltage values on the display.
- The displayed value is true RMS.
- Wait for 3 minutes before next operation.
5. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF
d) Resistance measurement (Ω)
Make sure all circuit parts, circuits, components, and other objects of measurement are disconnected from
the voltage supply and fully discharged..
1. Set the function dial to
.
2. Short press the SEL button 4x to select resistance measurement, “Ω” will show on the display.
3. Short press RANGE to toggle through ranges (indicated by decimal position).
4. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
5. Connect the test lead probes to the correct test points in the circuit:
- Red: Positive polarity “+”.
- Black: Negative polarity “-”.
� Check�the�lines�for�continuity�by�connecting�the�two�test�leads.�The�impedance�value�should�be�≤�0.5�Ω�
(inherent�impedance�of�the�measuring�lines).�If�the�value�is�≥�0.5�Ω,�check�the�terminal�connections�or�if�
there is any damage.
6. Read the voltage values on the display.
- “OL” will appear on the display if the maximum range is exceeded or if the circuit is open.
- When measuring high resistance, it is normal to take a few seconds for readings to stabilize.
7. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF
e) Continuity test ( )
Make sure all circuit parts, circuits, components, and other objects of measurement are disconnected from
the voltage supply and fully discharged.
1. Set the function dial to
.
2. Short press the SEL button 3x to select continuity test, “Ω
” will show on the display.
3. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
4. Connect the test lead probes to the correct test points in the circuit.
5. A�resistance�of�≤�30�Ω�is�considered�continuity,�and�a�beep�will�sound.
- The�measuring�range�is�≤�600�Ω.
- “OL” will appear on the display if the maximum range is exceeded or if the circuit is open.
6. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF.
f) Diode test (
)
Make sure all circuit parts, circuits, components, and other objects of measurement are disconnected from
the voltage supply and fully discharged.
The test voltage is approximately 3V.
1. Set the function dial to
.
2. Short press the SEL button 2x to select diode test, “
” will show on the display.
3. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
4. Check the lines for continuity by connecting the two test leads. The value should be approximately 0.000 V.
5. Connect the test lead probes to the correct test points on the diode.
- “OL” will appear on the display if the polarity is reversed or if the circuit is open.
- The normal PN junction forward voltage is approx. 500 to 800 mV.
6. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF.
g) Capacity measurement
Make sure all circuit parts, circuits, components, and other objects of measurement are disconnected from
the voltage supply and fully discharged.
Always observe polarity with electrolyte capacitors.
1. Set the function dial to
.
2. Short press the SEL button 1x to select capacity measurement, “nF” unit or capacitance will show on the display.
3. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
4. Connect the test lead probes to the correct test points on the capacitor.
- Always observe the polarity with electrolyte capacitors.
- “OL” will appear on the display if the polarity is reversed or if the circuit is shorted.
- Wait until the displayed value has stabilized. This may take a few seconds for capacities >40 µF.
5. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF.
h) Frequency (>10 Hz) / duty ratio measurement (%)
This measuring function is not suitable for measuring mains current!
The DMM can be used to measure and indicate signal voltage frequencies up to 1 MHz.
The maximum input amplitude is 30 Vrms.
Please observe the input values in the technical data.
1. Set the function dial to Hz%, Hz will appear on the display.
2. Short press the SEL button to switch between frequency “Hz” and duty ratio “%” measurement.
Frequency measurements: Short press RANGE to toggle through ranges (indicated by decimal position).
3. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM terminal.
4. Connect the test lead probes to the correct test points in the circuit.
Duty ratio: The pulse duration of the positive half wave is displayed as a percentage. 50% is displayed for
a symmetrical signal.
5. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF.
i) Temperature measurement
Do not get the temperature probe wet!
1. Set the function dial to °C°F.
2. Short press the SEL button to select a unit of measurement, “°C” or
“°F” will show on the display.
3. Connect the K-type thermocouple to the terminals.
- “TEMP +” plug to the
terminal.
- “COM -” plug to the COM terminal.
4. Measure the temperature at the probe tip.
- “OL” will appear on the display when the DMM is turned on.
- The measured temperature should be < 400 °C / 752 °F (°F = °C × 1.8 + 32)
5. When�finished�measuring,�disconnect�the�test�leads�and�switch�the�power�OFF.
j) Current measurement / Frequency (40 to 400 Hz)
This measuring function is suitable for measuring mains current.
�
To�prevent�possible�electric�shock,�fire�or�personal�injury,�switch�off�the�power�supply�of�the�circuit,�and�then�
connect the DMM to the circuit in series before measuring the current.
If the range of the measured current is unknown, always start at the highest measurement range and switch
down to lower ranges if needed.
There are fuses inside “10 A” and “mA μA” input terminals. Do not connect the test leads to circuits in
parallel.
A warning will sound when measured values are out of range >10 A.
Measuring >5 A must only be performed for max. 30 seconds and at 15 minute intervals.
1. Set the function dial to µA
, mA
, or A
, the corresponding unit of measurement will appear on the display.
2. Short press the SEL button to cycle through “DC”, “AC”, “Hz”.
3. Connect the test leads to the terminals:
- Red test lead to the
terminal.
- Black test lead to the COM or 10A max terminal
4. Connect the test lead probes to the circuit in series.
5. Read the value on the display.
- DC current: The polarity is shown together with the measured value.
- AC current: Values are given in true RMS.
- Frequency:�Measuring�range�is�40�to�400�Hz�(input�amplitude�≥�range�×�50�%).
6. When�finished�measuring,�disconnect�the�test�leads,�power�the�circuit�down�and�switch�the�DMM�power�OFF
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
-
+
12. Additional functions
Button press:
Short press = <2 sec.
Long press = Press and hold >2 sec.
a) Access sub functions
Several measuring functions are assigned sub functions, and are marked in red around the function dial. Short press
the SEL button to cycle through each sub function.
b) Range
Pressing the RANGE button will switch the DMM from automatic “Auto” range to manual range.
This mode is only applicable with the following functions: V
, V
, Ω, Hz, µA
, mA
, and A
.
• Enter manual range: Short press the RANGE button.
- “Auto” will disappear from the display.
- Short press RANGE to toggle through ranges (indicated by decimal position).
• Exit manual range: Long press the RANGE button or rotate the function dial, “Auto” will appear on the display.
c) Hold
The hold function keeps the indicated value on the display so you have more time to read or record it.
If you test live wires, make sure this function is deactivated before the measurement starts. Otherwise, the
measurement will not be correct.
• Short press the HOLD button to activate/deactivate the hold.
• The
symbol will appear to indicate that hold is active.
d) Peak
• This function allows users to capture faster signal events than the normal min/max function. Input changes of 1
millisecond or longer will be recorded.
• This mode is only available with the following functions: V
, mV
, µA
, mA
, and A
.
• Long press the PEAK button to enter/exit peak value mode.
• Short press the PEAK button to cycle through “P-MAX” and “P-MIN” values.
e) Maximum / Minimum
This function permits saving and display of maximum or minimum values during a series of measurements. Auto-
range will be deactivated.
• This mode is only applicable with the following functions: LOZV
, LPFV
, V
, V
, mV
, Ω, µA
, mA
, A
, and °C/°F.
• Select the proper range before selecting MAX MIN to ensure that the MAX MIN reading will not exceed the
measurement range.
• The values are taken from the time MAX MIN mode was entered. Input changes of 100 milliseconds or longer will
be recorded.
• Long press the MAX MIN button to enter/exit maximum and minimum measurement mode.
• Short press the MAX MIN button to cycle through measurements:
- Maximum value: MAX will show on the display.
- Minimum value: MIN will show on the display.
f) Automatic power off
Automatic power off is an energy saving feature. When activated, the power will turn off if there is no activity is
detected for approximately 15 mins. Press any button or adjust the function dial to wake.
1Disable auto-power off
1. Set the function dial to the OFF position.
2. While pressing and holding the SEL/PEAK button, turn the function dial to any position.
3. The
symbol will disappear.
2Activate auto-power off
• Restart the device by setting the function dial OFF then ON again.
• The
symbol will show.
g) Automatic backlight
When ambient light levels fall below a certain threshold, the backlight automatically turns ON (duration: 30 secs). In
bright circumstances, the backlight automatically turns OFF.
13. Replacing the Fuse
Never operate the meter if the case is open. !DANGER TO LIFE!
1. Turn the function dial to the “OFF”
position.
2. Remove the test leads from the input
terminals.
3. Unscrew then remove the battery cover.
4. Unscrew the rear cover screws.
5. Replace the fuse with one that is of the
same� type� and� specification.� Refer� to�
the section “Technical data” for further
information.
6. Carefully replace the covers.
14. Troubleshooting
Problem
Possbile cause
Suggested solution
The DMM will not power up.
Flat battery
Replace with new battery.
Cannot measure changes
in value.
Is the wrong measuring function
activated (AC/DC)?
Check display (AC/DC) and switch the function
if required.
Are the incorrect leads used?
Check the terminal assignment or connection
of the probe leads.
Is the HOLD function activated?
Deactivate the HOLD function.
No measurement possible
in the A measurement
range
Is the fuse of the A measuring
range defective?
Check the 10 A F2 fuse
No measurement possible
in the mA/µA measurement
range
Is the fuse of the mA/µA meas-
urement range defective?
Check the 0.6 A F1 fuse.
15. Cleaning and maintenance
a) Cleaning
Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can cause
damage to the housing and malfunctioning.
• Disconnect the product from the mains before each cleaning.
• Clean�the�product�with�a�dry,�fibre-free�cloth.
• If there is any malfunction, stop using the meter and send it for maintenance. Maintenance and service must only
be�carried�out�by�qualified�professionals.
b) Maintenance
• The DMM should be calibrated once a year for maximum accuracy.
• The DMM does not require maintenance other than battery and fuse replacement.
• Check the device and measuring lines for signs of wear and damage.
16. Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this product conforms to the
2014/53/EU directive.
Click on the following link to read the full text of the EU declaration of conformity:
www.conrad.com/downloads
�
Select�a�language�by�clicking�on�a�flag�symbol�and�enter�the�product�order�number�in�the�search�box.�You�
can then download the EU declaration of conformity in PDF format.
Electronic devices are recyclable waste and must not be disposed of in the household waste. At the end of
its service life, dispose of the product in accordance with applicable regulatory guidelines.
Remove any inserted (rechargeable) batteries and dispose of them separately from the product.
b) (Rechargeable) batteries
�
You�as�the�end�user�are�required�by�law�(Battery�Ordinance)�to�return�all�used�(rechargeable)�batteries.�
Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labeled with this symbol to indicate that disposal in the domestic
waste is forbidden. The designations for the heavy metals involved are: Cd = Cadmium, Hg = Mercury,
Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores or wherever
(rechargeable) batteries are sold.
You�thus�fulfill�your�statutory�obligations�and�contribute�to�the�protection�of�the�environment.
18. Technical data
a) General
Voltage supply ..................................................9 V block battery (6F22, NEDA 1604 or same)
Operating time/battery ......................................approx. 120 h (without backlight)
Measuring impedance ......................................approx.�10�MΩ�(600�mV:�≥1000�MΩ)
Display range ....................................................6000 counts (characters)
Refresh rate ......................................................2-3x per sec
Temperature measurement ..............................-40 to +400 °C (-40 to 752 °F)
Measuring method AC ......................................True RMS
Measuring line length .......................................each approx. 80 cm
Low battery indicator ........................................≤6�V�±0.2�V
Measuring jacks distance .................................19 mm (COM-V)
Auto power off ..................................................approx. 15 minutes
Data hold ..........................................................approx. 15 minutes
Measuring category ..........................................≤�CAT�III�600�V
Degree of contamination ..................................2
Direct voltage ....................................................max. 600.0 V / DC
Alternating voltage ............................................max. 600.0 V / AC
Direct current ....................................................max. 10.00 A / DC
Alternating current ............................................max. 10.00 A / AC
Resistance ........................................................max.�60�MΩ
Capacitance ......................................................max. 60 mF
Operating temperature .....................................0 to 40 °C
Storage temperature .........................................-10 to +50 °C
Operating/storage humidity ..............................�0�˚C�to�30�˚C:�≤75�%�RH�(non-condensing)�
30�˚C�to�40�˚C:�≤�50�%�RH�(non-condensing)
Operating altitude .............................................max. 2000 m (above sea level)
Dimensions (W x H x D): ..................................75 x 150.6 x 38 mm
Weight ..............................................................approx. 221 g (without battery)
b) Fuses
F1 Fuse ............................................................ ø6 x 32 mm, 0.6 A H600 V FF
Input�terminal�protection�(μA,�mA)
F2 Fuse ............................................................ ø6 x 25 mm, 10 A H600 V FF
Input terminal protection (A)
c) Measurement tolerances
Accuracy:�±�(%�of�reading�+�count)
The accuracy is valid for one year at:
• Ambient�temperature:�+3�°C�(±�5�°C),�≤75�%,�RH�non-condensing
• Operating�temperature*:�18�to�28�°C�(±1�°C)�
*A�temperature�coefficient�applies�outside�of�this�temperature�range:�+0.1�x�(specified�accuracy)�/�°C.
The�measurement�can�be�impaired�when�the�device�is�operated�within�a�high-frequency�electromagnetic�field.�
d) Capacitance measurement
Range
Resolution
Accuracy
6.000 nF
1 pF
±�(5�%�+�10)
60.00�nF�-�600.0�μF
10�pF�-�0.1�μF
±�(4�%�+�7)
6.000 mF - 60.00 mF
1�μF�-�10�μF
±�13�%
Overload protection: 600 V
e) Continuity ( ) and diode (
) test
Range
Resolution
Remark
0.1Ω
• Open�circuit:�Resistance�>100�Ω,�no�beep.
• Circuit�with�a�good�connection:�Resistance�≤30�Ω,�consecutive�beeps.
1 mV
• Open circuit voltage: Approx. 3 V
• Silicon PN junction voltage: Appox. 0.5 to 0.8 V
Overload protection: 600 V
f) DC voltage measurement
Range
Resolution
Accuracy
600.0 mV
0.1 mV
±�(0.9�%�+�4)
6.000 V
0.001 V
±�(0.6�%�+�4)
60.00 V
0.01 V
±�(0.9�%�+�4)
600.0 V
0.1 V
• Input�impedance:�≥1000�MΩ�for�mV�range�(short�circuit�allows�≤5�digits),�approx�10�MΩ�for�other�ranges.
• Input voltage: max. 600 V
g) AC voltage measurement
Range
Resolution
Accuracy
600.0 mV
0.1m V
±�(1.3�%�+�5)
6.000 V
0.001 V
±�(1.0�%�+�5)
60.00 V
0.01 V
±�(1.3�%�+�4)
600.0 V
0.1 V
±�(1.3�%�+�4)
LoZ ACV 600.0 V
0.1 V
±�(2.6�%�+�4)
LPF ACV 600.0 V
0.1 V
±�(2.5�%�+�6)
• Input�impedance:�approx.�10�MΩ.
• True RMS display.
• Frequency response: 40 - 400 Hz. LPF frequency response: 40 - 200 Hz.
• After using the LoZ function, please cool down the meter for 1 minute.
• Accuracy�guarantee�range:�5~100%�of�range,�short�circuit�allows�least�significant�digit�<10.
• The�AC�crest�factor�is�≤3.0�when�measured�at�3000�counts.�The�full�range�AC�crest�factor�of�6000�counts�is�
≤1.5.
• Non-sinusoidal waveforms:
- When the crest factor is 1.0 to 2.0, the accuracy must be increased by 4.0 %.
- When the crest factor is 2.0 to 2.5, the accuracy must be increased by 5.0 %.
- When the crest factor is 2.5 to 3.0, the accuracy must be increased by 7.0 %.
• Input voltage: max. 600 Vrms.
h) Resistance measurement (Ω)
Range
Resolution
Accuracy
600.0�Ω
0.1�Ω
±�(1.3�%�+�3)
6.000�kΩ
1�Ω
±�(1.0�%�+�3)
60.00�kΩ
10�Ω
600.0�kΩ
100�Ω
6.000�MΩ
1�kΩ
±�(1.6�%�+�4)
60.00�MΩ
10�kΩ
±�(3.0�%�+�7)
Overload protection: 600 V
i) Frequency / duty ratio measurement
Range
Resolution
Accuracy
10.00 Hz - 1.00 MHz
0.01 Hz - 0.001 MHz
±�(0.1�%�+�6)
0.1 % - 99.9 %
0.1 %
±�(3�%�+�6)
• Overload protection: 600 V
• Input amplitude a: (DC level = 0)
≤100�kHz:�200�mVrms�≤�a�≤�30�Vrms
>100�kHz�-�1�MHz:�600�mVrms�≤�a�≤�30�Vrms
• Duty�ratio�measurement�is�applicable�to�square�waves�with�frequency�≤10kHz.
1�Vpp�≤�Input�amplitude�≤�30�Vpp.
Frequency�≤�1�kHz,�duty�ratio:�10.0�%�to�95.0�%.
Frequency > 1 kHz, duty ratio: 30.0 % to 70.0 %
j) DC current measurement
Range
Resolution
Accuracy
μA
600.0�μA
0.1�μA
±�(1.0�%�+�4)
6000�μA
1�μA
mA
60.00 mA
10�μA
600.0 mA
0.1 mA
A
6.000 A
1 mA
±�(1.3�%�+�4)
10.00 A
10 mA
±�(1.5�%�+�6)
• When�the�measured�current�is�>5�A,�each�measurement�time�should�be�≤30�s�and�the�rest�interval�should�be�
≥15�minutes.
• Overload protection:
- F1�Fuse:�μA�mA�range,�ø6�x�32�mm,�0.6�A�H600�V�FF(CE)
- F2 Fuse: 10A range, ø6 x 25 mm, 10 A H600 V FF (CE)
k) Temperature measurement
Range
Resolution
Accuracy
°C
-40 to +400 °C
-40 to +300 °C
0.1 to 1 °C
±�(1.4�%�+�3�°C)
300 to 400 °C
°F
-40 to +752 °F
-40 to +572 °F
0.2 to 2 °F
±�(1.4�%�+�5�°F)
572 to 752°F
• Overload protection: 600 V
• The K-type thermocouple is only suitable for measuring temperatures < 400 °C (752 °F).
l) AC current measurement
Range
Resolution
Accuracy
μA
600.0μA
0.1�μA
±�(1.3�%�+�4)
6000μA
1�μA
mA
60.00 mA
10�μA
600.0 mA
0.1 mA
A
6.000 A
1 mA
±�(1.6�%�+�4)
10.00 A
10 mA
±�(1.8�%�+�6)
• When�the�measured�current�is�>5�A,�each�measurement�time�should�be�≤30�s�and�the�rest�interval�should�be�
≥15�minutes.
• True RMS display.
• Frequency response: 40 - 400 Hz.
• Accuracy�guarantee�range:�5�-�100�%�of�range,�short�circuit�allows�least�significant�digit�<2.
• The�AC�crest�factor�is�≤3.0�when�measured�at�3000�counts.�The�full�range�AC�crest�factor�of�6000�counts�is�
≤1.5.
• Non-sinusoidal waveforms:
- When the crest factor is 1.0 - 2.0, the accuracy must be increased by 4.0 %.
- When the crest factor is 2.0 - 2.5, the accuracy must be increased by 5.0%.
- When the crest factor is 2.5 - 3.0, the accuracy must be increased by 7.0%.
• Overload protection:
- F1�Fuse:�μA�mA�range,�ø6�x�32�mm,�0.6�A�H600�V�FF(CE)
- F2 Fuse: 10A range, ø6 x 25 mm, 10 A H600 V FF (CE)
Table des matières
Page
1.
Introduction ........................................................................................................................................................59
2.
Explication des symboles ..................................................................................................................................59
3.
Utilisation prévue ...............................................................................................................................................60
4.
Contenu de l’emballage .....................................................................................................................................60
5.
Mode d’emploi actualisé ....................................................................................................................................60
6.
Caractéristiques et fonctions .............................................................................................................................60
7.
Consignes de sécurité .......................................................................................................................................61
a) Informations générales ................................................................................................................................61
b) Appareils connectés ....................................................................................................................................61
c) Fusible .........................................................................................................................................................62
d) Piles/accumulateurs ....................................................................................................................................62
e) Multimètre ....................................................................................................................................................62
f) Sondes ........................................................................................................................................................63
8.
Éléments de fonctionnement .............................................................................................................................64
a) Vue d’ensemble ...........................................................................................................................................64
b) Molette .........................................................................................................................................................65
9.�
Affichage�et�symboles ........................................................................................................................................66
10. Insertion/remplacement des piles ......................................................................................................................67
11. Fonctionnement .................................................................................................................................................67
a) Mise en marche ...........................................................................................................................................67
b) Mesure de la tension CC/CA .......................................................................................................................68
c) Mesure de la tension alternative LoZ ..........................................................................................................69
d)� Mesure�de�la�résistance�(Ω) ........................................................................................................................69
e) Test de continuité (
) .................................................................................................................................70
f) Test de diode (
) ......................................................................................................................................70
g) Mesure de la capacité .................................................................................................................................71
h) Fréquence (>10 Hz)/mesure du rapport cyclique (%)..................................................................................71
i) Mesure de la température ...........................................................................................................................72
j) Mesure du courant/Fréquence (40 à 400 Hz) ..............................................................................................72
12. Fonctions supplémentaires ................................................................................................................................73
a) Accès aux sous-fonctions ............................................................................................................................73
b) Plage ...........................................................................................................................................................73
c) Maintien .......................................................................................................................................................73
d) Crête ............................................................................................................................................................73
e) Maximum/Minimum .....................................................................................................................................74
f) Arrêt automatique ........................................................................................................................................74
g) Rétro-éclairage automatique .......................................................................................................................74
13. Remplacement du fusible ..................................................................................................................................75
14. Dépannage ........................................................................................................................................................75
15. Nettoyage et entretien .......................................................................................................................................76
a) Nettoyage ....................................................................................................................................................76
b) Entretien ......................................................................................................................................................76
16. Déclaration de conformité (DOC) ......................................................................................................................76
17. Élimination des déchets .....................................................................................................................................77
a) Produit .........................................................................................................................................................77
b) Piles/accumulateurs ....................................................................................................................................77
18. Caractéristiques techniques ..............................................................................................................................78
a) Généralités ..................................................................................................................................................78
b) Fusibles .......................................................................................................................................................78
c) Tolérances de mesure .................................................................................................................................79
d) Mesure de la capacité .................................................................................................................................79
e) Test de continuité (
) et de diode (
) ....................................................................................................79
f) Mesure de la tension CC .............................................................................................................................79
g) Mesure de la tension CA .............................................................................................................................80
h)� Mesure�de�la�résistance�(Ω) ........................................................................................................................80
i) Fréquence /mesure du rapport cyclique ......................................................................................................81
j) Mesure du courant CC ................................................................................................................................81
k) Mesure de la température ...........................................................................................................................82
l) Mesure du courant CA .................................................................................................................................82
Chère cliente, cher client,
Merci d’avoir acheté ce produit.
Ce produit est conforme aux exigences nationales et européennes en vigueur.
Afin�de�préserver�cette�conformité�et�de�garantir�un�fonctionnement�en�toute�sécurité,�vous�devez�respecter�ce�mode�
d’emploi !
Ce mode d’emploi fait partie de ce produit. Il contient des informations importantes concernant la mise en
service et l'utilisation. Vous devez prendre cela en considération si vous devez fournir ce produit à un tiers.
Par�conséquent,�conservez�ce�mode�d'emploi�afin�de�pouvoir�vous�y�référer�ultérieurement�!
Pour toute question technique, veuillez vous adresser à:
France (email):
[email protected]
Suisse:
www.conrad.ch
2. Explication des symboles
Le symbole avec l’éclair dans un triangle
indique qu’il y a un risque pour votre santé, par
ex. en raison d’une décharge électrique.
Le symbole avec le point d’exclamation dans
un triangle sert à indiquer les informations
importantes présentes dans ce mode d’emploi.
Veuillez lire ces informations attentivement.
� Le� symbole� de� la� flèche� indique� des�
informations� spécifiques� et� des� conseils�
spéciaux pour le fonctionnement.
Cet appareil est conforme à la norme CE
et répond aux directives européennes
applicables.
Classe de protection 2 (isolation double ou
renforcée, isolation de protection).
Mise à la terre
CAT I
Catégorie de mesure I pour les mesures sur
les appareils électriques et électroniques
qui ne sont pas directement alimentés par la
tension du réseau (par exemple, les appareils
à piles, les basses tensions de protection, les
tensions de signal et de commande, etc.)
CAT II
Catégorie de mesure II pour les mesures
sur les appareils électriques et électroniques
connectés directement au réseau électrique
via une prise de courant. Cette catégorie
comprend également toutes les catégories
inférieures (telles que CAT I pour la mesure
des tensions du signal et des tensions de
commande).
CAT III
Catégorie de mesure III pour les mesures dans
les installations de bâtiment (par exemple, les
points de vente ou la sous-distribution). Cette
catégorie comprend également toutes les
sous-catégories (par ex. CAT II pour la mesure
des appareils électroniques). L’opération
de mesure dans la CAT III est autorisée
uniquement avec des sondes de mesure ayant
une longueur de contact libre maximale de
4 mm ou avec des capuchons de protection
au-dessus des sondes de mesure.
3. Utilisation prévue
Le�produit�est�destiné�à�être�utilisé�comme�un�multimètre�numérique�(DMM),�les�valeurs�mesurées�sont�affichées�sur�
un écran numérique. Le DMM peut être utilisé pour des applications professionnelles, industrielles et de bricolage
jusqu’à CAT III. Il est uniquement destiné à une utilisation à l’intérieur. Dans tous les cas, le contact avec l’humidité
doit être évité.
Pour�des�raisons�de�sécurité�et�d’homologation,�toute�restructuration�et/ou�modification�du�produit�est�interdite.�Toute�
utilisation�à�des�fins�autres�que�celles�décrites�ci-dessus�pourrait�endommager�le�produit.�De�plus,�une�mauvaise�
utilisation pourrait entraîner des risques tels que les courts-circuits, les incendies, les chocs électriques, etc. Lisez
attentivement les instructions du mode d’emploi et conservez-le dans un endroit sûr. Ne mettez ce produit à la
disposition de tiers qu’avec son mode d’emploi.
Tous les noms d’entreprises et appellations de produits sont des marques commerciales de leurs propriétaires
respectifs. Tous droits réservés.
4. Contenu de l’emballage
• Multimètre numérique
• Cordons de mesure (en paire)
• Sonde de température à contact ponctuel
• Pile bloc 9 V
• Consignes de sécurité
• Mode d’emploi (sur CD-ROM)
5. Mode d’emploi actualisé
Téléchargez le mode d’emploi le plus récent sur www.conrad.com/downloads ou scannez le code
QR�indiqué.�Suivez�les�instructions�figurant�sur�le�site�Web.
6. Caractéristiques et fonctions
• Mesure de la tension CA/CC
• Mesure du courant CA/CC jusqu’à 10 A.
• Cycle de service
• Test de diode
• Testeur de continuité acoustique
• Fonction de maintien
• Mise hors tension automatique.
• Rétro-éclairage automatique de l’écran
• Valeur de crête (PEAK)
• 6000 points
• valeur�efficace�vraie�
• Plage automatique
• Fusibles haute performance 600 V
• Catégorie de mesure CAT III 600 V
7. Consignes de sécurité
Lisez attentivement le mode d’emploi et observez particulièrement les consignes de sécurité.
Nous déclinons toute responsabilité en cas de dommages corporels ou matériels résultant du
non-respect des consignes de sécurité et des informations relatives à la manipulation correcte
contenues dans ce manuel. De tels cas entraînent l’annulation de la garantie.
a) Informations générales
• Cet appareil n’est pas un jouet. Il doit rester hors de portée des enfants et des animaux domestiques.
• Ne laissez pas traîner le matériau d’emballage. Celui-ci peut se révéler dangereux si des enfants le
prennent pour un jouet.
• Gardez l'appareil à l’abri de températures extrêmes, de la lumière directe du soleil, de secousses
intenses,�d’humidité�élevée,�d’eau,�de�gaz�inflammables,�de�vapeurs�et�de�solvants.
• N’exposez pas le produit à des contraintes mécaniques.
• Si une utilisation du produit en toute sécurité n'est plus possible, arrêtez de l’utiliser et protégez-le de
toute utilisation accidentelle. Un fonctionnement sûr ne peut plus être garanti si le produit :
- est visiblement endommagé,
- ne fonctionne plus correctement,
- a été stocké pendant une période prolongée dans des conditions défavorables ou
- a été transporté dans des conditions très rudes.
• Manipulez le produit avec précaution. Des secousses, des chocs ou une chute, même de faible hauteur,
peuvent endommager le produit.
• Consultez un spécialiste en cas de doute sur le fonctionnement, la sécurité ou le raccordement de
l'appareil.
• L’entretien,�les�modifications�et�les�réparations�doivent�être�effectués�uniquement�par�un�technicien�ou�
un centre de réparation agréé.
• Si vous avez des questions qui sont restées sans réponse après avoir lu toutes les instructions
d’utilisation, contactez notre service de support technique ou un autre technicien spécialisé.
• Dans les établissements commerciaux, il convient de respecter les réglementations relatives à la
prévention des accidents de la compagnie d'assurance de responsabilité civile de l'employeur en ce qui
concerne les systèmes électriques et le matériel d’exploitation.
• Dans les écoles, les centres de formation, les ateliers d’informatique et d'auto-assistance, la manipulation
des multimètres doit être supervisée de manière responsable par un personnel formé.
b) Appareils connectés
• Respectez les instructions de sécurité et d'utilisation de tout autre appareil connecté à ce produit.
réparez pas et ne pontez pas un fusible défectueux, car cela pourrait provoquer un incendie ou entraîner
un choc électrique mortel.
d) Piles/accumulateurs
• Respectez les indications de polarité lorsque vous insérez les piles/accumulateurs.
• Retirez�les�piles/accumulateurs�de�l’appareil�s’il�n’est�pas�utilisé�pendant�longtemps�afin�d’éviter�les�
dégâts causés par des fuites. Des piles/accumulateurs qui fuient ou qui sont endommagées peuvent
provoquer�des�brûlures�acides�lors�du�contact�avec�la�peau�;�l’utilisation�de�gants�protecteurs�appropriés�
est par conséquent recommandée pour manipuler les piles/accumulateurs corrompues.
• Gardez les piles/accumulateurs hors de portée des enfants. Ne laissez pas traîner de piles/
accumulateurs, car des enfants ou des animaux pourraient les avaler.
• Il convient de remplacer toutes les piles/accumulateurs en même temps. Le mélange de piles/
accumulateurs anciennes et de nouvelles piles/accumulateurs dans l’appareil peut entraîner la fuite
d’accumulateurs et endommager l’appareil.
• Les piles/accumulateurs ne doivent pas être démantelées, court-circuitées ou jetées dans un feu. Ne
rechargez pas les piles non rechargeables. Cela constituerait un risque d’explosion !
e) Multimètre
• N’allumez pas l’appareil après son passage d’un environnement froid à un environnement chaud. La
condensation qui se forme pourrait détruire l'appareil. Attendez que l’appareil ait atteint la température
ambiante avant de l’allumer.
• Avant�chaque�mesure,�vérifiez�que�le�multimètre�est�réglé�sur�la�fonction�appropriée.
• Pour éviter tout choc électrique, ne touchez pas les connexions/points de mesure directement
ou� indirectement� pendant� la� mesure.� Avant� chaque� mesure,� vérifiez� que� le� multimètre� n’est� pas�
endommagé. N'effectuez jamais de mesures si l’isolation de protection est endommagée (déchirée,
rompue, etc).
• Ne l’utilisez pas pendant les orages.
• Ne faites jamais fonctionner le produit à proximité directe de champs magnétiques ou électromagnétiques
puissants ou d’antennes émettrices ou de générateurs HF. Cela pourrait affecter la mesure.
• Pour des mesures précises, remplacez la pile lorsque le symbole de pile faible apparaît à l’écran.
• Faites attention aux informations disponibles à côté des panneaux d’avertissement
sur les bornes
du cordon de mesure. La tension ou le courant mesuré ne doit pas dépasser les valeurs indiquées !
• Ne faites jamais fonctionner le multimètre lorsque le boîtier est ouvert. !DANGER DE MORT !
• Les câbles de sondes disposent d’un indicateur d’usure. Lorsqu’ils sont endommagés, une deuxième
couche d’isolation de couleur différente devient visible. Les accessoires de mesure ne doivent plus être
utilisés et doivent être remplacés.
• Pendant la mesure, évitez de saisir au-delà des marques de la plage
de préhension indiquées sur les sondes de mesure.
• En cas d’utilisation des sondes de mesure sans capuchon, les
mesures entre le multimètre et le potentiel de terre ne doivent pas
être effectuées au-delà de la catégorie de mesure CAT II.
• Lors d’une mesure dans la catégorie CAT III. Les sondes de mesure
avec capuchon (longueur de contact libre de 4 mm max.) doivent
être utilisées pour éviter les courts-circuits accidentels pendant la mesure. Elles sont fournies.
• Les sondes de mesure doivent être retirées de l’objet mesuré chaque fois que la fonction de mesure
est�modifiée.
• La tension entre les points de connexion du multimètre et le potentiel de terre ne doit pas dépasser
600 V CC/CA en CAT III.
• Risque de choc électrique fatal ! Faites attention lorsque vous utilisez des tensions supérieures à
33 V/CA ou 70 V/CC.
8. Éléments de fonctionnement
a) Vue d’ensemble
0
9
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
OFF
LoZ
V
LPF
%
F
C
Hz
Hz
Hz
Hz
Hz
Hz
HOLD/MAX MIN
RANGE
SEL/PEAK
C
D
E
G
J
K
H
I
A
B
F
A Borne de 10 A max
B Bouton RANGE
C Bouton SEL/PEAK
D Capteur de rétro-éclairage automatique
E Écran
F Bouton HOLD/MAX MIN
G Molette de fonctions
H Borne
I Borne COM
J Couvercle du compartiment à piles
K Support dépliable
• Ajustez la molette pour choisir une fonction.
• La sélection de la plage automatique (« Auto ») est
activée dans la majorité des modes de mesure.
• Certaines fonctions ont des sous-fonctions, celles-ci
sont marquées en rouge et sont accessibles via une
pression sur le bouton SEL/PEAK.
• Réglez toujours la molette sur « OFF » lorsque l’appareil
n’est pas utilisé.
Fonction
Description
V
, V
, mV
Mesure de la tension CA/CC
Ω
Mesure de la résistance
Test de diode
Test de continuité
Mesure de la capacité
Hz
Mesure de la fréquence
%
Mesure du rapport cyclique
°C/°F
Mesure de la température
µA
, mA
, A
Mesure du courant/de la fréquence CA/CC
LPF V
Mesure�du�filtre�passe-bas�pour�la�tension�alternative
LoZ V
Mesure de la faible impédance d'une tension alternative
OFF
Mise hors tension
9. Affichage et symboles
CF
C
%
LoZ
LoZ
LoZ
P-MAX P-MIN
LO
Icône
Description
Batterie faible
Mise hors tension automatique
Auto
Plage automatique
Mesure�du�filtre�passe-bas
LoZ
Mesure de la faible impédance
P-MAX/P-MIN
Mesure de la valeur de crête
MAX/MIN
Mesure maximale/minimale
Conservation des données
Tension élevée
AC
Signal CA
DC
Signal CC
mV, V
Unités de tension : millivolt, volt
µA, mA, A
Unités de courant : microampère, milliampère, ampère
Ω, kΩ, MΩ
Unités de résistance : ohm, kilo ohm, mégaohm
nF, µF, mF
Unités de capacité : nanofarad, microfarad, millifarad
Hz, kHz, Mhz
Unités de fréquence : hertz, kilohertz, mégahertz
%
Mesure du rapport cyclique
OL
Non-continuité (boucle ouverte) ou résistance dépassant la portée maximale.
10. Insertion/remplacement des piles
Avant d’ouvrir le couvercle arrière, coupez
l’alimentation électrique et débranchez les
cordons de test des bornes d’entrée et du
circuit.
1. Lorsque� la� tension� de� la� pile� est� ≤6� V� ±0,2� V,� le�
symbole de pile faible
�s’affiche.�
2. Mettez la molette de fonctions sur la position « OFF »
et retirez les cordons de test des bornes d’entrée.
3. Dévissez et retirez le couvercle de la pile pour la
remplacer.
11. Fonctionnement
Remplacez la pile si l’avertissement de pile faible
� s’affiche.� Faites� attention� aux� informations�
disponibles à côté des panneaux d’avertissement marqués sur le DMM
à côté des bornes du plomb de
test. La tension ou le courant mesuré ne doit pas dépasser les valeurs
indiquées !
�
Test�sur�des�tensions�connues�pour�vérifier�que�le�DMM�fonctionne�correctement.
Pour obtenir des résultats de mesure précis, assurez-vous que les extrémités de la sonde et toutes les
zones de contact sont exemptes de débris ou de résidus.
a) Mise en marche
• Allumage : Réglez le cadran de fonction sur la fonction de mesure correspondante.
• Arrêt : Réglez la molette de fonctions sur « OFF ». Lorsque vous ne l’utilisez pas, éteignez toujours l’instrument
de mesure.
b) Mesure de la tension CC/CA
�
L’impédance�d’entrée�est�d’environ�10�MΩ�et�ne�mettra�pas�beaucoup�de�pression�sur�le�circuit.
1. Régler la molette de fonctions sur le paramètre souhaité :
• Mesure de la tension CC (V
),�«�DC�»�s’affiche�à�l’écran.
- Appuyez brièvement sur RANGE pour basculer entre les plages (indiquées par la position décimale).
• Mesure de la tension CA (V
),�«�AC�»�s’affiche�à�l’écran.
- Appuyez brièvement sur RANGE pour basculer entre les
plages (indiquées par la position décimale).
2. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
3. Connectez les sondes du câble de test aux points de test
appropriés dans le circuit :
- Rouge : Polarité positive « + ».
- Noir : Polarité négative « - ».
4. Lisez les valeurs de tension à l’écran.
- Tension CC (V
) : Si un signe moins « - » apparaît devant la valeur, la tension mesurée est négative (ou les
lignes de mesure sont permutées).
- Les�mesures�de�tension�CA�sont�données�en�valeur�efficace�réelle.
Un avertissement retentit lorsque les valeurs mesurées sont hors de la plage >600 V.
5. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
c) Mesure de la tension alternative LoZ
La fonction de mesure LoZ permet de mesurer la tension alternative « CA » avec une faible impédance (environ
300�kΩ).�La�faible�résistance�interne�du�multimètre�réduit�les�écarts�de�mesure�tels�que�les�tensions�fantômes.�
� L’impédance�d’entrée�est�d’environ�300�kΩ�et�soumettra�le�circuit�à�une�forte�contrainte.�
1. Réglez la molette de fonctions sur LoZ V
.
2. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
3. Connectez les sondes du câble de test aux points de test appropriés dans le circuit :
- Rouge : Polarité positive « + ».
- Noir : Polarité négative « - ».
4. Lisez les valeurs de tension à l’écran.
- La�valeur�affichée�est�en�valeur�efficace�vraie.
- Patientez 3 minutes avant la prochaine opération.
5. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
d) Mesure de la résistance (Ω)
Assurez-vous que toutes les parties de circuit, circuits, composants et autres objets de mesure sont
déconnectés de l’alimentation électrique et entièrement déchargés.
1. Réglez la molette de fonctions sur
.
2. Appuyez brièvement sur la touche SEL 4x pour sélectionner la mesure de résistance, « Ω�»�s’affiche�à�l’écran.
3. Appuyez brièvement sur RANGE pour basculer entre les plages (indiquées par la position décimale).
4. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
5. Connectez les sondes du câble de test aux points de test appropriés dans le circuit :
- Rouge : Polarité positive « + ».
- Noir : Polarité négative « - ».
� Vérifiez�la�continuité�des�lignes�en�connectant�les�deux�cordons�de�test.�La�valeur�de�l’impédance�doit�être�
≤�0,5�Ω�(impédance�inhérente�aux�lignes�de�mesure).�Si�la�valeur�est�≥�0,5�Ω,�vérifiez�les�connexions�du�
terminal ou la présence de dommages.
6. Lisez les valeurs de tension à l’écran.
- « OL » apparaîtra sur l’écran si la portée maximale est dépassée ou si le circuit est ouvert.
- Lors de la mesure d’une résistance élevée, il est normal de prendre quelques secondes pour que les valeurs
se stabilisent.
7. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
e) Test de continuité ( )
Assurez-vous que toutes les parties de circuit, circuits, composants et autres objets de mesure sont
déconnectés de l’alimentation électrique et entièrement déchargés.
1. Réglez la molette de fonctions sur
.
2. Appuyez brièvement sur la touche SEL 3x pour sélectionner le test de continuité, « Ω
�»�s’affiche�à�l’écran.
3. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
4. Connectez les sondes du câble de test aux points de test appropriés dans le circuit.
5. Une�résistance�≤�30�Ω�est�considérée�comme�une�continuité,�et�un�bip�sonore�retentit.
- La�plage�de�mesure�est�≤�600�Ω.
- « OL » apparaîtra sur l’écran si la portée maximale est dépassée ou si le circuit est ouvert.
6. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
f) Test de diode (
)
Assurez-vous que toutes les parties de circuit, circuits, composants et autres objets de mesure sont
déconnectés de l’alimentation électrique et entièrement déchargés.
La tension de test est d’environ 3 V.
1. Réglez la molette de fonctions sur
.
2. Appuyez brièvement sur la touche SEL 2x pour sélectionner le test à diodes, «
�»�s’affiche�à�l’écran.
3. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
4. Vérifiez�la�continuité�des�lignes�en�connectant�les�deux�cordons�de�test.�La�valeur�devrait�être�d’environ�0,000�V.
5. Connectez les sondes du câble de test aux points de test appropriés du diode.
- « OL » apparaîtra sur l’écran si la portée est inversée ou si le circuit est ouvert.
- La tension directe normale de la jonction PN est d’environ 500 à 800 mV.
6. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
g) Mesure de la capacité
Assurez-vous que toutes les parties de circuit, circuits, composants et autres objets de mesure sont
déconnectés de l’alimentation électrique et entièrement déchargés.
Respectez toujours la polarité avec les condensateurs électrolytiques.
1. Réglez la molette de fonctions sur
.
2. Appuyez brièvement sur la touche SEL 1x pour sélectionner la mesure de la capacité, l’unité « nF » ou la capacité
s’affiche�à�l’écran.
3. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
4. Connectez les sondes du câble de test aux points de test appropriés du condensateur.
- Respectez toujours la polarité avec les condensateurs électrolytiques.
- « OL » apparaîtra sur l’écran si la portée est inversée ou en cas de court-circuit.
- Attendez�que�la�valeur�affichée�se�soit�stabilisée.�Cela�peut�prendre�quelques�secondes�pour�des�capacités�
>40 µF.
5. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
h) Fréquence (>10 Hz)/mesure du rapport cyclique (%)
Cette fonction de mesure n’est pas adaptée à la mesure du courant du secteur !
Le DMM peut être utilisé pour mesurer et indiquer les fréquences de tension du signal allant jusqu’à 1 MHz.
L’amplitude d’entrée maximale est de 30 Vrms.
Veuillez respecter les valeurs d’entrée dans les caractéristiques techniques.
1. Réglez la molette de fonctions sur Hz%, Hz apparaît à l’écran.
2. Appuyez brièvement sur le bouton SEL pour passer de la mesure de la fréquence « Hz » à celle du rapport
cyclique « % ».
Mesure de la fréquence : Appuyez brièvement sur RANGE pour basculer entre les plages (indiquées par
la position décimale).
3. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM.
4. Connectez les sondes du câble de test aux points de test appropriés dans le circuit.
� Rapport�cyclique�:�La�durée�d’impulsion�de�la�demi-onde�positive�s’affiche�en�pourcentage.�50�%�est�affiché�
pour un signal symétrique.
5. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
i) Mesure de la température
Ne mouillez pas la sonde de température !
1. Réglez la molette de fonctions sur °C°F.
2. Appuyez brièvement sur la touche SEL pour sélectionner une unité
de mesure, « °C » ou « °F�»�s’affichera�à�l’écran.
3. Connecter le thermocouple de type K aux bornes.
- La�fiche�«�TEMP + » au terminal
.
- La�fiche�«�COM - » à la borne COM.
4. Mesurez la température à l’extrémité de la sonde.
- « OL » apparaîtra à l’écran lorsque le DMM est allumé.
- La température mesurée doit être < 400 °C/752 °F (°F = °C × 1,8 + 32)
5. Une fois les mesures terminées, débranchez les câbles de test et mettez l’appareil hors tension.
j) Mesure du courant/Fréquence (40 à 400 Hz)
Cette fonction de mesure est adaptée à la mesure du courant du secteur.
Pour éviter tout risque de choc électrique, d’incendie ou de blessure, coupez l’alimentation électrique du
circuit, puis connectez le DMM au circuit en série avant de mesurer le courant.
Si la plage du courant mesuré est inconnue, commencez toujours par la plage de mesure la plus élevée et
passez à des plages inférieures si nécessaire.
Les bornes d’entrée sont équipées de fusibles « 10 A » et « mA μA ». Ne connectez pas les cordons de
test à des circuits en parallèle.
Un avertissement retentit lorsque les valeurs mesurées sont hors de la plage >10 A.
Une mesure >5 A ne doit être effectuée que pendant 30 secondes max. et à 15 minutes d’intervalle.
1. Réglez la molette de fonctions sur µA
, mA
, ou A
, l’unité de mesure correspondante apparaît à l’écran.
2. Appuyez brièvement sur le bouton SEL�pour�faire�défiler�les�valeurs�«�DC », « AC », « Hz ».
3. Connecter les cordons de test aux bornes :
- Le câble de test rouge à la borne
.
- Le câble de test noir à la borne COM ou 10 A max
4. Connectez les sondes du câble de test au circuit en série.
5. Lisez la valeur à l’écran.
- Courant continu : La polarité est indiquée en même temps que la valeur mesurée.
- AC�alternatif�:�Les�valeurs�sont�données�en�valeur�efficace�réelle.
- Fréquence�:�La�plage�de�mesure�est�de�40�à�400�Hz�(amplitude�d’entrée�≥�plage�×�50�%).
6. Une fois les mesures terminées, débranchez les câbles de test, mettez le circuit hors tension et coupez
l’alimentation du DMM
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
-
+
12. Fonctions supplémentaires
Pression sur le bouton :
Brève pression = <2 s.
Longue pression = pression et maintien >2 s.
a) Accès aux sous-fonctions
Plusieurs fonctions de mesure se voient attribuer des sous-fofnctions, et sont marquées en rouge autour de la molette
de fonctions. Appuyez brièvement sur le bouton SEL pour passer en revue chaque sous-fonction.
b) Plage
En appuyant sur le bouton RANGE, le DMM passe de la plage automatique « Auto » à la plage manuelle.
Ce mode n’est applicable qu’avec les fonctions suivantes : V
, V
, Ω, Hz, µA
, mA
, et A
.
• Accéder à la plage manuelle : Appuyez brièvement sur le bouton RANGE.
- « Auto » disparaît de l’écran.
- Appuyez brièvement sur RANGE pour basculer entre les plages (indiquées par la position décimale).
• Quitter la plage manuelle : Appuyez longuement sur la touche RANGE ou faites tourner la molette de fonctions,
« Auto » apparaît à l’écran.
c) Maintien
La fonction de maintien permet de conserver la valeur indiquée à l’écran, ce qui vous laisse plus de temps pour la
lire ou l’enregistrer.
� Si�vous�testez�des�fils�sous�tension,�assurez-vous�que�cette�fonction�est�désactivée�avant�le�début�de�la�
mesure. Dans le cas contraire, la mesure ne sera pas correcte.
• Appuyez brièvement sur le bouton HOLD pour activer/désactiver le maintien.
• Le symbole
apparaît pour indiquer que le maintien est actif.
d) Crête
• Cette fonction permet aux utilisateurs de capturer des signaux plus rapidement que la fonction min/max normale.
Les changements d’entrée de 1 milliseconde ou plus seront enregistrés.
• Ce mode n’est disponible qu’avec les fonctions suivantes : V
, mV
, µA
, mA
, et A
.
• Appuyez longuement sur la touche PEAK pour accéder/quitter le mode valeur de crête.
• Appuyez brièvement sur la touche PEAK�pour�faire�défiler�les�valeurs�«�P-MAX�»�et�«�P-MIN�».
La portée automatique sera désactivée.
• Ce mode n’est applicable qu’avec les fonctions suivantes : LOZV
, LPFV
, V
, V
, mV
, Ω, µA
, mA
,
A
, et °C/°F.
• Sélectionnez la plage appropriée avant de choisir MAX MIN pour vous assurer que la valeur MAX MIN ne dépasse
pas la plage de mesure.
• Les valeurs sont prises à partir du moment où le mode MAX MIN a été activé. Les changements d’entrée de
100 milliseconde ou plus seront enregistrés.
• Appuyez longuement sur le bouton MAX MIN pour accéder/quitter le mode de mesure maximum et minimum.
• Appuyez brièvement sur le bouton MAX MIN�pour�faire�défiler�les�mesures�:
- Valeur maximale : MAX�s’affiche�à�l’écran.
- Valeur minimale : MIN�s’affiche�à�l’écran.�
f) Arrêt automatique
L’arrêt automatique est une mesure d’économie d’énergie. Lorsqu’il est activé, l’appareil s’éteint si aucune activité
n’est détectée pendant environ 15 minutes. Appuyez sur n’importe quel bouton ou réglez le cadran de fonction pour
le rallumer.
1Désactiver l’arrêt automatique
1. Régler la molette de fonctions sur OFF.
2. Tout en maintenant la touche SEL/PEAK enfoncée, tournez la molette de fonctions sur n’importe quelle position.
3. Le symbole
disparaît.
2Activer l’arrêt automatique
• Redémarrez l’appareil en réglant le sélecteur de fonction sur OFF puis à nouveau sur ON.
• Le symbole
apparaît.
g) Rétro-éclairage automatique
Lorsque le niveau de lumière ambiante tombe en dessous d’un certain seuil, le rétro-éclairage s’allume
automatiquement (durée : 30 s). En cas de forte luminosité, le rétro-éclairage s’éteint automatiquement.
13. Remplacement du fusible
Ne faites jamais fonctionner le multimètre lorsque le boîtier est ouvert. !DANGER DE MORT !
1. Régler la molette de fonctions à la position
« OFF ».
2. Retirez les cordons de test des bornes
d’entrée.
3. Dévissez puis retirez le couvercle du
compartiment à piles.
4. Dévissez les vis du couvercle arrière.
5. Remplacez le fusible par un autre de
même� type� et� de� même� spécification.�
Pour plus d’informations, voir la section
« Caractéristiques techniques ».
6. Remettez les couvercles en place avec
précaution.
14. Dépannage
Problème
Causes possibles
Solution suggérée
La DMM ne s’allume pas.
Pile faible
Remplacer par une nouvelle pile.
Ne peut pas mesurer les
changements de valeur.
Une fonction de mesure
inappropriée est-elle activée
(CA/CC) ?
Vérifiez�l’affichage�(CA/CC)�et�changez�la�
fonction si nécessaire.
Les câbles utilisées sont-il
inappropriés ?
Vérifiez�l’affectation�des�bornes�ou�la�
connexion des câbles de la sonde.
La fonction HOLD est-elle
activée ?
Désactivez la fonction HOLD.
Aucune mesure possible
dans la plage de mesure A
Le fusible de la plage de
mesure A est-il défectueux ?
Vérifiez�le�fusible�10�A�F2
Aucune mesure possible
dans la plage de
mesure mA/µA
Le fusible de la plage
de mesure mA/µA est-il
défectueux ?
Vérifiez�le�fusible�0,6�A�F1.
15. Nettoyage et entretien
a) Nettoyage
N’utilisez pas de nettoyage agressif, d’alcool isopropylique ou toute autre solution chimique, car ils peuvent
endommager le boîtier et engendrer des dysfonctionnements.
• Avant le nettoyage, débranchez le produit de l’alimentation électrique.
• Nettoyez�le�produit�avec�un�chiffon�sec�et�sans�fibres.
• En cas de dysfonctionnement, arrêtez d’utiliser le multimètre et envoyez-le à la maintenance. La maintenance et
l’entretien�ne�doivent�être�effectués�que�par�des�professionnels�qualifiés.
b) Entretien
• Le DMM doit être étalonné une fois par an pour une précision maximale.
• Le DMM ne nécessite pas de maintenance autre que le remplacement des piles et des fusibles.
• Vérifiez�si�l’appareil�et�les�lignes�de�mesure�présentent�des�signes�d’usure�et�de�détérioration.
16. Déclaration de conformité (DOC)
Conrad Electronic SE, Klaus-Conrad-Strasse 1, D-92240 Hirschau, déclare par la présente que ce produit est
conforme à la directive 2014/53/UE.
Le texte intégral de la déclaration de conformité UE est disponible au lien suivant :
www.conrad.com/downloads
Sélectionnez une langue en cliquant sur le drapeau correspondant puis saisissez le numéro de commande
du produit dans le champ de recherche pour pouvoir télécharger la déclaration de conformité UE sous
format PDF.
17. Élimination des déchets
a) Produit
Les appareils électroniques sont des matériaux recyclables et ne doivent pas être éliminés avec les
ordures�ménagères.�En�fin�de�vie,�éliminez�l’appareil�conformément�aux�dispositions�légales�en�vigueur.�
Retirez les piles/accumulateurs insérées et mettez-les au rebut séparément du produit.
b) Piles/accumulateurs
�
Le�consommateur�final�est�légalement�tenu�(ordonnance�relative�à�l´élimination�des�piles�usagées)�de�
rapporter toutes les piles et tous accumulateurs usagés. Il est interdit de les mettre au rebut avec les
ordures ménagères.
Les piles/accumulateurs usagées portent ce symbole pour indiquer qu’il est interdit de les jeter dans
les ordures ménagères. Les désignations pour le métal lourd prépondérant sont : Cd = cadmium,
Hg = mercure, Pb = plomb (la désignation se trouve sur les piles/accumulateurs, par ex. sous le symbole
de la poubelle illustré à gauche).
Les piles/accumulateurs utilisées peuvent être retournées dans des points de collecte mis en place par votre
municipalité, nos magasins ou tout point de vente de piles et des batteries rechargeables.
Ainsi, vous respectez les ordonnances légales et contribuez à la protection de l’environnement.
18. Caractéristiques techniques
a) Généralités
Alimentation électrique .....................................pile bloc 9 V (6F22, NEDA 1604 ou équivalent)
Temps de fonctionnement/pile ..........................env. 120 h (sans rétro-éclairage)
Mesure de l’impédance ....................................env.�10�MΩ�(600�mV�:�≥1�000�MΩ)
Plage�d’affichage ..............................................6000 points (caractères)
Taux de rafraîchissement .................................2-3x par seconde
Mesure de la température ................................-40 à +400 °C (-40 à 752 °F)
Méthode de mesure CA ....................................valeur�efficace�vraie
Mesure de la longueur des lignes .....................env. 80 cm chacune
Indicateur de pile faible .....................................≤6�V�±0,2�V
Mesurer la distance entre les prises .................19 mm (COM-V)
Arrêt automatique .............................................env. 15 minutes
Maintien des données ......................................env. 15 minutes
Catégorie de mesure ........................................≤�CAT�III�600�V
Degré de contamination ...................................2
Tension continue ...............................................600,0 V/CC max.
Tension alternative ............................................600,0 V/CA max.
Courant continu ................................................10,00 A/CC max.
Courant alternatif ..............................................10,00 A/CA max.
Résistance ........................................................60�MΩ�max.
Capacité ...........................................................60 mF max.
Température de fonctionnement .......................0 à 40 °C
Température enregistrée ..................................-10�˚C�à�50�˚C
Humidité de fonctionnement/stockage .............�0�˚C�à�30�˚C�:�≤75�%�HR�(sans�condensation)�
30�˚C�à�40�˚C:�≤50�%�HR�(sans�condensation)
Altitude de fonctionnement ...............................max. 2 000 m (au-dessus du niveau de la mer)
Dimensions (L x H x P): ....................................75 x 150,6 x 38 mm
Poids .................................................................env. 221 g (sans pile)
b) Fusibles
Fusible F1 ......................................................... ø6 x 32 mm, 0,6 A H600 V FF
Protection�des�terminaux�d’entrée�(μA,�mA)
Fusible F2 ......................................................... ø6 x 25 mm, 10 A H600 V FF
Protection des terminaux d’entrée (A)
c) Tolérances de mesure
Précision�:�±�(%�lecture�+�point)
La précision est valable pendant un an à :
• Température�ambiante�:�+3�°C�(±�5�°C),�≤75�%,�HR�sans�condensation
• Température�de�fonctionnement*�:�18�à�28�°C�(±1�°C)�
*Un�coefficient�de�température�s’applique�en�dehors�de�cette�plage�de�température�:�+0,1�x�(précision�spécifiée)/°C.
La mesure peut être biaisée lorsque l’appareil est utilisé dans un champ électromagnétique à haute fréquence.
d) Mesure de la capacité
Portée
Résolution
Précision
6,000 nF
1 pF
±�(5�%�+�10)
60,00�nF�-�600,0�μF
10�pF�-�0,1�μF
±�(4�%�+�7)
6,000 mF - 60,00 mF
1�μF�-�10�μF
±�13�%
Protection contre les surcharges : 600 V
e) Test de continuité ( ) et de diode (
)
Portée
Résolution
Remarque
0,1�Ω
• Circuit�ouvert�:�Résistance�>100�Ω,�aucun�bip.
• Circuit�avec�une�bonne�connexion�:�Résistance�≤30�Ω,�bips�consécutifs.
1 mV
• Tension de circuit ouvert : env. 3 V
• Tension de jonction PN en silicone : env. 0,5 à 0,8 V
Protection contre les surcharges : 600 V
f) Mesure de la tension CC
Portée
Résolution
Précision
600,0 mV
0,1 mV
±�(0,9�%�+�4)
6,000 V
0,001 V
±�(0,6�%�+�4)
60,00 V
0,01 V
±�(0,9�%�+�4)
600,0 V
0,1 V
• Impédance�d’entrée�:�≥�1�000�MΩ�pour�la�plage�mV�(un�court-circuit�permet�d’utiliser�les�chiffres�≤5),�environ�
10�M�pour�les�autres�plages.
• Tension d’entrée : 600 V max.
g) Mesure de la tension CA
Portée
Résolution
Précision
600,0 mV
0,1 mV
±�(1,3�%�+�5)
6,000 V
0,001 V
±�(1,0�%�+�5)
60,00 V
0,01 V
±�(1,3�%�+�4)
600,0 V
0,1 V
±�(1,3�%�+�4)
LoZ V CA 600,0 V
0,1 V
±�(2,6�%�+�4)
LPF VCA 600,0 V
0,1 V
±�(2,5�%�+�6)
• Impédance�d'entrée�:�env.�10�MΩ.
• Affichage�en�valeur�efficace�vraie.
• Réponse en fréquence : 40 - 400 Hz. Réponse en fréquence LPF : 40 - 200 Hz.
• Après avoir utilisé la fonction LoZ, veuillez laisser le multimètre refroidir pendant 1 minute.
• Plage�de�garantie�de�la�précision�:�5~100�%�de�la�portée,�un�court-circuit�permet�le�chiffre�le�moins�significatif�<10.
• Le�facteur�de�crête�CA�est�≤3,0�lorsqu’il� est�mesuré�à�3�000�points.�Le�facteur�de�crête�CA�complet�de�
6�000�comptes�est�≤1,5.
• Formes d’ondes non sinusoïdales :
- Lorsque le facteur de crête est de 1,0 à 2,0, la précision doit être augmentée de 4,0 %.
- Lorsque le facteur de crête est de 2,0 à 2,5, la précision doit être augmentée de 5,0 %.
- Lorsque le facteur de crête est de 2,5 à 3,0, la précision doit être augmentée de 7,0 %.
• Tension�d’entrée�:�600�V�max.�en�valeur�efficace.
h) Mesure de la résistance (Ω)
Portée
Résolution
Précision
600,0�Ω
0,1�Ω
±�(1,3�%�+�3)
6,000�KΩ
1�Ω
±�(1,0�%�+�3)
60,00�KΩ
10�Ω
600,0�KΩ
100�Ω
6,000�MΩ
1�kΩ
±�(1,6�%�+�4)
60,00�MΩ
10�kΩ
±�(3,0�%�+�7)
Protection contre les surcharges : 600 V
i) Fréquence /mesure du rapport cyclique
Portée
Résolution
Précision
10,00 Hz - 1,00 MHz
0,01 Hz - 0,001 MHz
±�(0,1�%�+�6)
0,1 %-99,9 %
0,1 %
±�(3�%�+�6)
• Protection contre les surcharges : 600 V
• Amplitude d’entrée a : (Niveau CC = 0)
≤100�kHz�:�200�mV�en�valeur�efficace�≤�a�≤�30�V�en�valeur�efficace
>100�kHz�-�1�MHz�:�600�mV�en�valeur�efficace�≤�a�≤�30�V�en�valeur�efficace
• La�mesure�du�rapport�cyclique�est�applicable�aux�ondes�carrées�de�fréquence�≤10�kHz.
1�Vpp�≤�Amplitude�d’entrée�≤�30�Vpp.
Fréquence�≤�1�kHz,�rapport�cyclique�:�10,0�%�à�95,0�%
Fréquence > 1 kHz, rapport cyclique : de 30,0 % à 70,0 %
j) Mesure du courant CC
Portée
Résolution
Précision
μA
600,0�μA
0,1�μA
±�(1,0�%�+�4)
6000�μA
1�μA
mA
60,00 mA
10�μA
600,0 mA
0,1 mA
A
6,000 A
1 mA
±�(1,3�%�+�4)
10,00 A
10 mA
±�(1,5�%�+�6)
• Lorsque�le�courant�mesuré�est�>5�A,�chaque�temps�de�mesure�doit�être�≤30�s�et�l’intervalle�de�repos�doit�être�
≥15�minutes.
• Protection contre les surcharges :
- Fusible�F1�:�plage�μA�mA,�ø6�x�32�mm,�0,6�A�H600�V�FF(CE)
- Fusible F2 : Plage de 10 A, ø6 x 25 mm, 10 A H600 V FF (CE)
k) Mesure de la température
Portée
Résolution
Précision
°C
-40 à +400 °C
-40 à +300 °C
0,1 à 1 °C
±�(1,4�%�+�3�°C)
300 à 400 °C
°F
-40 à +752 °F
-40 à +572 °F
0,2 à 2 °F
±�(1,4�%�+�5�°F)
572 à 752 °F
• Protection contre les surcharges : 600 V
• Le thermocouple de type K est uniquement adapté à la mesure de températures < 400 °C (752 °F).
l) Mesure du courant CA
Portée
Résolution
Précision
μA
600,0�μA
0,1�μA
±�(1,3�%�+�4)
6�000�μA
1�μA
mA
60,00 mA
10�μA
600,0 mA
0,1 mA
A
6,000 A
1 mA
±�(1,6�%�+�4)
10,00 A
10 mA
±�(1,8�%�+�6)
• Lorsque�le�courant�mesuré�est�>5�A,�chaque�temps�de�mesure�doit�être�≤30�s�et�l’intervalle�de�repos�doit�être�
≥15�minutes.
• Affichage�en�valeur�efficace�vraie.
• Réponse en fréquence : 40 - 400 Hz.
• Plage�de�garantie�de�la�précision�:�5�-�100�%�de�la�portée,�un�court-circuit�permet�le�chiffre�le�moins�significatif�<2.
• Le�facteur�de�crête�CA�est�≤3,0�lorsqu’il�est�mesuré�à�3�000�points.�Le�facteur�de�crête�CA�complet�de�
6�000�comptes�est�≤1,5.
• Formes d’ondes non sinusoïdales :
- Lorsque le facteur de crête est de 1,0 à 2,0, la précision doit être augmentée de 4,0 %.
- Lorsque le facteur de crête est de 2,0 à 2,5, la précision doit être augmentée de 5,0 %.
- Lorsque le facteur de crête est de 2,5 à 3,0, la précision doit être augmentée de 7,0 %.
• Protection contre les surcharges :
- Fusible�F1�:�plage�μA�mA,�ø6�x�32�mm,�0,6�A�H600�V�FF(CE)
- Fusible F2 : Plage de 10 A, ø6 x 25 mm, 10 A H600 V FF (CE)
Verklaring van de tekens ...................................................................................................................................85
3.
Beoogd gebruik ..................................................................................................................................................86
4.
Leveringsomvang ..............................................................................................................................................86
5.
Meest recente gebruiksaanwijzing .....................................................................................................................86
6.
Eigenschappen en functies ................................................................................................................................86
7.
Veiligheidsinstructies .........................................................................................................................................87
a) Algemene informatie ....................................................................................................................................87
b) Aangesloten apparaten ...............................................................................................................................87
c) Zekering .......................................................................................................................................................88
d) Batterij/accu’s ..............................................................................................................................................88
e) Multimeter ....................................................................................................................................................88
f) Sondes ........................................................................................................................................................89
8.
Bedieningselementen ........................................................................................................................................90
a) Overzicht .....................................................................................................................................................90
b) Draaiknop ....................................................................................................................................................91
9.
Display en symbolen ..........................................................................................................................................92
10. Batterijen plaatsen/vervangen ...........................................................................................................................93
11. Bediening ...........................................................................................................................................................93
a) Voeding AAN ...............................................................................................................................................93
b) DC/AC-spanningsmeting .............................................................................................................................94
c) LoZ AC-spanningsmeting ............................................................................................................................95
d)� Weerstandsmeting�(Ω).................................................................................................................................95
e) Continuïteitstest (
) ...................................................................................................................................96
f) Diodetest (
) ............................................................................................................................................96
g) Capaciteitsmeting ........................................................................................................................................97
h) Frequentie (>10 Hz) / bedrijfscyclusmeting (%)...........................................................................................97
i) Temperatuurmeting ......................................................................................................................................98
j) Stroommeting/frequentie (40 tot 400 Hz) ....................................................................................................98
12. Aanvullende functies ..........................................................................................................................................99
a) Subfuncties openen .....................................................................................................................................99
b) Bereik ..........................................................................................................................................................99
c) Houd ............................................................................................................................................................99
d) Piek ..............................................................................................................................................................99
e) Maximum / minimum .................................................................................................................................100
f) Automatische uitschakeling .......................................................................................................................100
g) Automatisch achtergrondlicht ....................................................................................................................100
13. De zekering vervangen ....................................................................................................................................101
14. Problemen oplossen ........................................................................................................................................101
15. Reiniging en onderhoud ...................................................................................................................................102
a) Reiniging ....................................................................................................................................................102
b) Onderhoud .................................................................................................................................................102
16. Conformiteitsverklaring (DOC) .........................................................................................................................102
17. Verwijdering .....................................................................................................................................................103
a) Product ......................................................................................................................................................103
b) Batterij/accu’s ............................................................................................................................................103
18. Technische gegevens ......................................................................................................................................104
a) Algemeen ..................................................................................................................................................104
b) Zekeringen .................................................................................................................................................104
c) Meettoleranties ..........................................................................................................................................105
d) Capaciteitsmeting ......................................................................................................................................105
e) Continuïteitstest (
) en diodetest (
) ...................................................................................................105
f) DC-spanningsmeting .................................................................................................................................105
g) AC-spanningsmeting .................................................................................................................................106
h)� Weerstandsmeting�(Ω)...............................................................................................................................106
i) Frequentiemeting / bedrijfscyclusmeting ...................................................................................................107
j) DC-stroommeting ......................................................................................................................................107
k) Temperatuurmeting ....................................................................................................................................108
l) AC-stroommeting .......................................................................................................................................108
Hartelijk dank voor de aankoop van dit product.
Het product is voldoet aan de nationale en Europese wettelijke voorschriften.
Om deze status te handhaven en een veilige werking te garanderen, dient u als eindgebruiker deze gebruiksaanwijzing
in acht te nemen!
Deze gebruiksaanwijzing is een onderdeel van dit product. Deze bevat belangrijke informatie over de
werking en hantering van het product. Als u dit product aan derden overhandigt, doe dan tevens deze
gebruiksaanwijzing erbij. Bewaar deze gebruiksaanwijzing voor toekomstige raadpleging!
Bij technische vragen kunt u zich wenden tot onze helpdesk. Voor meer informative kunt u kijken op www.conrad.nl
of www.conrad.be
2. Verklaring van de tekens
Het symbool met een bliksemschicht in
een driehoek wijst op een risico voor uw
gezondheid, bijv. door een elektrische schok.
Dit symbool met het uitroepteken in een
driehoek wordt gebruikt om belangrijke
informatie in deze gebruiksaanwijzing te
onderstrepen. Lees deze informatie altijd
aandachtig door.
Het pijl-symbool duidt op speciale informatie
en advies voor het gebruik.
Dit apparaat is conform CE en voldoet aan de
toepasbare Europese richtlijnen.
Beschermingsklasse 2 (dubbele of versterkte
isolatie, beschermende isolatie).
Aarde
CAT I
Meetcategorie I voor metingen op elektrische
en elektronische apparaten die niet direct
van netspanning worden voorzien (bijv.
apparaten op batterijvoeding, beschermende
laagspanning, signaal- en bedieningsspanning,
enz.).
CAT II
Meetcategorie II voor metingen op elektrische
en elektronische apparaten direct aangesloten
op netspanning via een netstekker. Deze
categorie dekt tevens alle lagere categorieën
(bijv. CAT I voor het meten van signaal en
bedieningsspanning).
CAT III
Meetcategorie
III
voor
metingen
in
gebouwinstallaties (bijv. stopcontacten of
subdistributie). Deze categorie dekt tevens alle
lagere categorieën (bijv. CAT II voor het meten
van elektrische apparaten). Meetactiviteiten in
CAT III zijn alleen toegestaan met meetsondes
met een maximale vrije contactlengte van 4 mm
of met afdekdoppen boven de meetsondes.
3. Beoogd gebruik
Dit product is bestemd voor gebruik als een digitale multimeter (DMM), gemeten waarden worden weergegeven op
een digitale display. De DMM kan worden gebruikt voor professionele, industriële en doe-het-zelf toepassingen tot
CAT III. Dit product is alleen bedoeld voor gebruik binnenshuis. Contact met vocht moet absoluut worden vermeden.
Om veiligheids- en goedkeuringsredenen mag u niets aan dit product veranderen. Als het product voor andere
doeleinden wordt gebruikt dan hierboven beschreven, kan het worden beschadigd. Bovendien kan onjuist gebruik
resulteren in kortsluiting, brand, elektrische schokken of andere gevaren. Lees de gebruiksaanwijzing goed door
en bewaar deze op een veilige plek. Het product mag alleen samen met de gebruiksaanwijzing aan derden worden
doorgegeven.
Alle bedrijfs- en productnamen zijn handelsmerken van de betreffende eigenaren. Alle rechten voorbehouden.
4. Leveringsomvang
• Digitale multimeter
• Testkabels (paar)
• Puntcontacttemperatuursonde
• 9V-blokbatterij
• VEILIGHEIDSINFORMATIE
• Gebruiksaanwijzingen (op CD-ROM)
5. Meest recente gebruiksaanwijzing
Download de meest recente gebruiksaanwijzing via www.conrad.com/downloads of scan de
afgebeelde QR-code. Volg de aanwijzingen op de website op.
6. Eigenschappen en functies
• AC/DC-spanningsmeting
• AC/DC-stroommeting tot 10 A.
• Gebruikscyclus
• Diodetest
• Akoestische continuïteitstester
• Hold-functie
• Automatische uitschakeling.
• Automatische achtergrondverlichting voor display
• Pieklezing (PEAK)
• 6000 tellingen
• Echte RMS
• Automatisch bereik
• 600 V hoogwaardige zekeringen
• CAT III 600 V meetcategorie
Lees de gebruiksaanwijzing aandachtig door en neem vooral de veiligheidsinformatie in acht. Indien
de veiligheidsinstructies en de aanwijzingen voor een juiste bediening in deze gebruiksaanwijzing
niet worden opgevolgd, aanvaarden wij geen verantwoordelijkheid voor hieruit resulterend
persoonlijk letsel of materiële schade. In dergelijke gevallen vervalt de aansprakelijkheid/garantie.
a) Algemene informatie
• Dit apparaat is geen speelgoed. Houd het buiten het bereik van kinderen en huisdieren.
• Laat verpakkingsmateriaal niet achteloos rondslingeren. Dit kan voor kinderen gevaarlijk speelgoed
worden.
• Bescherm het product tegen extreme temperaturen, direct zonlicht, sterke schokken, hoge vochtigheid,
vocht, brandbare gassen, stoom en oplosmiddelen.
• Stel het product niet aan mechanische spanning bloot.
• Als het product niet langer veilig gebruikt kan worden, stel het dan buiten bedrijf en zorg ervoor dat
niemand het per ongeluk kan gebruiken. Veilig gebruik kan niet langer worden gegarandeerd als het
product:
- zichtbaar is beschadigd,
- niet meer naar behoren werkt,
- gedurende een langere periode onder slechte omstandigheden is opgeslagen of
- onderhevig is geweest aan ernstige transportbelasting.
• Behandel het product met zorg. Schokken, stoten of zelfs een val van geringe hoogte kunnen het
product beschadigen.
• Raadpleeg een expert als u vragen hebt over gebruik, veiligheid of aansluiting van het apparaat.
• Onderhoud, aanpassingen en reparaties mogen alleen uitgevoerd worden door een technicus of een
daartoe bevoegd servicecentrum.
• Als u nog vragen heeft die niet door deze gebruiksaanwijzing worden beantwoord, kunt u contact
opnemen met onze technische dienst of ander technisch personeel.
• In commerciële omgevingen dienen de Arbo-voorschriften ter voorkoming van ongevallen met
betrekking tot elektrische installaties en bedrijfsmiddelen in acht genomen te worden.
• Het gebruik van meters in scholen, trainingcentra, computer- en zelf-hulpwerkplaatsen moet op een
verantwoordelijke wijze onder toezicht worden gehouden door getraind personeel.
b) Aangesloten apparaten
• Neem de veiligheids- en gebruiksinstructies van andere apparaten die op het product zijn aangesloten
in acht.
Repareer of overbrug geen defecte zekering, omdat deze brand of een dodelijke elektrische schok kan
veroorzaken.
d) Batterij/accu’s
• Let op de juiste polariteit bij het plaatsen van de batterijen/accu’s.
• De batterijen/accu’s dienen uit het apparaat te worden verwijderd wanneer het gedurende langere tijd niet
wordt gebruikt om beschadiging door lekkage te voorkomen. Lekkende of beschadigde batterijen/accu’s
kunnen brandend zuur bij contact met de huid opleveren. Gebruik daarom veiligheidshandschoenen om
beschadigde batterijen/accu’s aan te pakken.
• Batterijen/accu’s moeten uit de buurt van kinderen worden gehouden. Laat batterijen/accu’s niet
rondslingeren omdat het gevaar bestaat dat kinderen en/of huisdieren ze inslikken.
• Alle batterijen/accu’s dienen op hetzelfde moment te worden vervangen. Het door elkaar gebruiken
van oude en nieuwe batterijen/accu’s in het apparaat kan leiden tot batterijlekkage en beschadiging
van het apparaat.
• Batterijen/accu’s mogen niet worden ontmanteld, kortgesloten of verbrand. Probeer nooit niet-oplaadbare
batterijen op te laden. Er bestaat explosiegevaar!
e) Multimeter
• Schakel de meter niet in nadat deze van een koude naar een warme omgeving is gebracht. De
condensatie die zich dan vormt, kan het apparaat permanent beschadigen. Laat het apparaat eerst op
kamertemperatuur komen voordat u deze inschakelt.
• Controleer of de multimeter ingesteld is op de juiste functie vóór elke meting.
• Om elektrische schokken te voorkomen, dient u de aansluit-/meetpunten tijdens de meting nooit direct
of indirect aan te raken. Controleer de meter vóór elke meting op beschadiging. Voer nooit metingen uit
als de beschermende isolatie is beschadigd (gescheurd, ontbrekend, etc.).
• Gebruik het apparaat niet tijdens onweer.
• Gebruik het product nooit in de directe nabijheid van krachtige magnetische of elektromagnetische
velden, zendantennes of HF-generatoren. De meting kan hierdoor worden aangetast.
• Om uw metingen nauwkeurig te houden, dient u de batterij te vervangen wanneer het “lage battery”-
symbooltje verschijnt op de display.
• Let goed op de informatie naast de waarschuwingsmarkeringen
bij de aansluitingen voor de
testkabels. De gemeten spanning of stroom mag de weergegeven waarden niet overschrijden!
• Gebruik de meter nooit wanneer de behuizing is geopend. !LEVENSGEVAARLIJK!
• De sondekabels zijn voorzien van een slijtage-indicator. In het geval van beschadiging, is er een
tweede isolatielaag in een verschillende kleur zichtbaar. De meetaccessoires mogen niet langer worden
gebruikt en moeten worden vervangen.
• Pak het tijdens de meting niet vast buiten de gripbereikmarkeringen
die op de meetsondes staan aangegeven.
• Wanneer u de meetsondes gebruikt zonder afdekdoppen, dan
mogen metingen tussen de meter en aardingspotentiaal niet worden
uitgevoerd boven meetcategorie CAT II.
• Wanneer u metingen uitvoert in meetcategorie CAT III. Meetsondes
met afdekdoppen (max. 4 mm vrije contactlengte) moeten worden
gebruikt om onbedoelde kortsluitingen tijdens de meting te voorkomen. Deze zijn ingesloten.
• De meetsondes moeten van het gemeten voorwerp worden verwijderd telkens wanneer de meetfunctie
wordt veranderd.
• De spanning tussen de aansluitpunten van de meter en aardingspotentiaal mag in CAT III nooit 600 V
DC/AC overschrijden.
• Risico op een fatale elektrische schok! Ben voorzichtig wanneer u werkt met spanningswaarden hoger
dan 33 V/AC of 70 V/DC.
MAX 30sec EACH 15min
OFF
LoZ
V
LPF
%
F
C
Hz
Hz
Hz
Hz
Hz
Hz
HOLD/MAX MIN
RANGE
SEL/PEAK
C
D
E
G
J
K
H
I
A
B
F
A 10 A max aansluitklem
B RANGE-toets
C SEL/PEAK-toets
D Sensor voor automatisch achtergrondlicht
E Display
F HOLD/MAX MIN-toets
G Functiedraaiknop
H
aansluitklem
I COM-aansluitklem
J Deksel batterijvak
K Uitklapbare steun
• Pas de draaiknop aan om een functie te kiezen.
• Automatische bereikkeuze (“Auto”) is in de meeste
meetmodi ingeschakeld.
• Sommige functies hebben subfuncties, deze staan in
het rood gemarkeerd en kunnen worden geopend door
op de toets SEL/PEAK te drukken.
• Stel de draaiknop altijd in op “OFF” wanneer niet in
gebruik.
Functie
Beschrijving
V
, V
, mV
AC/DC-spanningsmeting
Ω
Weerstandsmeting
Diodetest
Continuïteitstest
Capaciteitsmeting
Hz
Frequentiemeting
%
Bedrijfscyclusmeting
°C/°F
Temperatuurmeting
µA
, mA
, A
AC/DC-stroom-/frequentiemeting
LPF V
Meting�van�laagdoorlaatfilter�voor�AC-spanning
LoZ V
Meting van lage impedantie voor AC-spanning
OFF
Uitschakelen
9. Display en symbolen
CF
C
%
LoZ
LoZ
LoZ
P-MAX P-MIN
LO
Pictogram
Beschrijving
Batterij bijna leeg
Automatische uitschakeling
Auto
Automatisch bereik
Meting�van�laagdoorlaatfilter
LoZ
Meting van lage impedantie
P-MAX/P-MIN
Meting van piekwaarde
MAX/MIN
Maximum/minimum meting
Gegevens behouden
Hoogspanning
AC
AC-signaal
DC
DC-signaal
mV, V
Spanningseenheden: millivolt, volt
µA, mA, A
Stroomeenheden: microampère, milliampère, ampère
Ω, kΩ, MΩ
Weerstandseenheden: ohm, kilo ohm, megaohm
nF, µF, mF
Capaciteitseenheden: nanofarad, microfarad, millifarad
Hz, kHz, Mhz
Frequentie-eenheden: hertz, kilohertz, megahertz
%
Bedrijfscyclusmeting
OL
Niet-continuïteit (open circuit) of weerstand overschrijdt het max. bereik.
10. Batterijen plaatsen/vervangen
Voordat u de achterbehuizing opent, dient u de
voeding uit te schakelen en de testkabels los
te koppelen van de ingangsklemmen en het
circuit.
1. Wanneer� de� batterijspanning� ≤6� V� ±0,2� V� is,� dan�
zal het “lage batterij”-symbooltje
worden
weergegeven.
2. Draai de functiedraaiknop naar de stand “OFF” en
verwijder de testkabels van de ingangsklemmen.
3. Schroef de batterijklep los, verwijder deze en vervang
de batterij.
11. Bediening
Vervang de batterij wanneer de “lage batterij”-waarschuwing
verschijnt. Let goed op de informatie
naast de waarschuwingsmarkeringen gemarkeerd op de DMM
naast de aansluitingen voor de
testkabels. De gemeten spanning of stroom mag de weergegeven waarden niet overschrijden!
Voer een test uit op een bekende spanning om te controleren of de DMM correct werkt.
Voor nauwkeurige testresultaten, dient u ervoor te zorgen dat de toppen van de sondes en alle
contactoppervlakken vrij zijn van vuil of restjes.
a) Voeding AAN
• AAN schakelen: Draai de functiedraaiknop naar de corresponderende meetfunctie.
• UIT schakelen: Draai de functiedraaiknop naar “OFF”. Zet de multimeter altijd uit als u deze niet gebruikt.
1. Draai de functiedraaiknop naar de vereiste instelling:
• DC-spanningsmeting (V
), “DC” zal op de display worden weergegeven.
- Druk kort op RANGE om de bereiken te doorlopen (aangegeven door de decimaalpositie).
• AC-spanningsmeting (V
), “AC” zal op de display worden
weergegeven.
- Druk kort op RANGE om de bereiken te doorlopen
(aangegeven door de decimaalpositie).
2. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
3. Sluit de sondes van de testkabels aan op de juiste testpunten
in het circuit:
- Rood: Positieve polarieity “+”.
- Zwart: Negatieve polariteit “-”.
4. Lees de spanningswaarden af op de display.
- DC-spanningsmetingen (V
): Als er een minusteken “-” vóór de waarde verschijnt, dan is de gemeten spanning
negatief (of de meetkabels zijn omgewisseld).
- AC-spanningsmetingen worden uitgedrukt in echte RMS.
Er zal een waarschuwing klinken wanneer de gemeten waarden buiten het bereik van >600 V vallen.
5. Koppel de testkabels na de meting los en schakel het apparaat UIT.
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
c) LoZ AC-spanningsmeting
De�LoZ-meetfunctie�wordt�gebruikt�voor�“AC”�wisselspanningsmetingen�met�lage�impedantie�(ong.�300�kΩ).�De�lagere�
interne weerstand van de meter reduceert afwijkende meetresultaten zoals fantoomspanning.
� De�ingansimpedantie�is�ongeveer�300�k�en�zal�het�circuit�ietwat�belasten.�
1. Stek de functiedraaiknop in op LoZ V
.
2. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
3. Sluit de sondes van de testkabels aan op de juiste testpunten in het circuit:
- Rood: Positieve polarieity “+”.
- Zwart: Negatieve polariteit “-”.
4. Lees de spanningswaarden af op de display.
- De weergegeven waarde is echt RMS.
- Wacht 3 minuten vóór de volgende meting.
5. Koppel de testkabels na de meting los en schakel het apparaat UIT.
d) Weerstandsmeting (Ω)
Zorg ervoor dat alle circuitonderdelen, circuits, componenten en andere meetobjecten losgekoppeld zijn
van de voedingsspanning en volledig ontladen zijn.
1. Draai de functiedraaiknop naar
.
2. Druk 4x kort op de toets SEL om de weerstandsmeting te selecteren, “Ω” zal worden weergegeven op de display.
3. Druk kort op RANGE om de bereiken te doorlopen (aangegeven door de decimaalpositie).
4. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
5. Sluit de sondes van de testkabels aan op de juiste testpunten in het circuit:
- Rood: Positieve polarieity “+”.
- Zwart: Negatieve polariteit “-”.
Controleer de kabels op continuïteit door de twee testkabels aan te sluiten. De impedantiewaarde dient
≤�0,5�Ω�te�zijn�(inherente�impedantie�van�de�meetkabels).�Als�de�waarde�≥�0,5�Ω�is,�controleer�dan�de�
aansluitklemmen en zoek naar tekenen van beschadiging.
6. Lees de spanningswaarden af op de display.
- “OL” zal op de display verschijnen als het maximale bereik is overschreden of als het circuit open is.
- Wanneer u een hoge weerstand meet, dan is het normaal dat de lezingen pas na enkele seconden stabiliseren.
7. Koppel de testkabels na de meting los en schakel het apparaat UIT.
e) Continuïteitstest ( )
Zorg ervoor dat alle circuitonderdelen, circuits, componenten en andere meetobjecten losgekoppeld zijn
van de voedingsspanning en volledig ontladen zijn.
1. Draai de functiedraaiknop naar
.
2. Druk 3x kort op de toets SEL om de continuïteitstest te selecteren, “Ω
” zal worden weergegeven op de display.
3. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
4. Sluit de sondes van de testkabels aan op de juiste testpunten in het circuit.
5. Een�weerstand�van�≤�30�Ω�wordt�als�continuïteit�beschouwd,�en�er�zal�een�pieptoon�klinken.
- Het�meetbereik�is�≤�600�Ω.
- “OL” zal op de display verschijnen als het maximale bereik is overschreden of als het circuit open is.
6. Koppel de testkabels na de meting los en schakel het apparaat UIT.
f) Diodetest (
)
Zorg ervoor dat alle circuitonderdelen, circuits, componenten en andere meetobjecten losgekoppeld zijn
van de voedingsspanning en volledig ontladen zijn.
De testspanning is ongeveer 3V.
1. Draai de functiedraaiknop naar
.
2. Druk 2x kort op de toets SEL om de diodetest te selecteren, “
” zal worden weergegeven op de display.
3. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
4. Controleer de kabels op continuïteit door de twee testkabels aan te sluiten. De waarde dient ongeveer 0,000 V
te zijn.
5. Sluit de sondes van de testkabels aan op de juiste testpunten op de diode.
- “OL” zal op de display verschijnen als de polariteit is omgekeerd of als het circuit open is.
- De normale doorlaatspanning van het PN-knooppunt is ongeveer 500 tot 800 mV.
6. Koppel de testkabels na de meting los en schakel het apparaat UIT.
Zorg ervoor dat alle circuitonderdelen, circuits, componenten en andere meetobjecten losgekoppeld zijn
van de voedingsspanning en volledig ontladen zijn.
Let altijd op de polariteit met elektrolytcondensatoren.
1. Draai de functiedraaiknop naar
.
2. Druk 1x kort op de toet SEL om de capaciteitsmeting te selecteren, de capaciteit of eenheid “nF” zal op de display
worden weergegeven.
3. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
4. Sluit de sondes van de testkabels aan op de juiste testpunten op de condensator.
- Let altijd op de polariteit met elektrolytcondensatoren.
- “OL” zal op de display verschijnen als de polariteit is omgekeerd of als het circuit is kortgesloten.
- Wacht totdat de weergegeven waarde is gestabiliseerd. Dit kan enkele seconden duren voor capaciteitswaarden
>40 µF.
5. Koppel de testkabels na de meting los en schakel het apparaat UIT.
h) Frequentie (>10 Hz) / bedrijfscyclusmeting (%)
Deze meetfunctie is niet geschikt voor het meten van netstroom!
De DMM kan worden gebruikt om signaalspanningsfrequenties tot 1 MHz te meten en weer te geven.
De maximale ingangsamplitude is 30 Vrms.
Let a.u.b. op de ingangswaarden in de technische gegevens.
1. Draai de functiedraaiknop naar Hz%, Hz zal op de display verschijnen.
2. Druk kort op de toets SEL om te wisselen tussen de frequentiemeting “Hz” en bedrijfscyclusmeting “%”.
Frequentiemetingen: Druk kort op RANGE om de bereiken te doorlopen (aangegeven door de
decimaalpositie).
3. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM.
4. Sluit de sondes van de testkabels aan op de juiste testpunten in het circuit.
Bedrijfscyclus: De pulsduur van de positieve halve golf wordt weergegeven als een percentage. 50% wordt
weergegeven voor een symmetrisch signaal.
5. Koppel de testkabels na de meting los en schakel het apparaat UIT.
Laat de temperatuursonde niet nat worden!
1. Draai de functiedraaiknop naar °C°F.
2. Druk kort op de toets SEL om een meeteenheid te selecteren, “°C”
of “°F” zal worden weergegeven op de display.
3. Sluit de K-type thermokoppel aan op de aansluitklemmen.
- “TEMP +”-stekker op aansluitpunt
.
- “COM -”-stekker op aansluitklem COM.
4. Meet de temperatuur bij de sondetip.
- “OL” zal op de display verschijnen wanneer de DMM wordt
ingeschakeld.
- De gemeten temperatuur dient < 400 °C / 752 °F (°F = °C × 1,8 + 32) te zijn.
5. Koppel de testkabels na de meting los en schakel het apparaat UIT.
j) Stroommeting/frequentie (40 tot 400 Hz)
Deze meetfunctie is geschikt voor het meten van netstroom.
Om mogelijke elektrische schokken, brand of persoonlijk letsel te voorkomen, dient u de stroomtoevoer van het
circuit uit te schakelen en de DMM vervolgens in serie op het circuit aan te sluiten voordat u de stroom meet.
Als het bereik van de gemeten stroom onbekend is, dient u altijd met het hoogste meetbereik te starten en
indien nodig op een lager bereik te schakelen.
Er zitten zekeringen binnenin aansluitklemmen “10 A” en “mA μA”. Sluit de testkabels niet in parallel aan
op circuits.
Er zal een waarschuwing klinken wanneer gemeten waarden buiten het bereik >10 A vallen.
Metingen >5 A mogen alleen max. 30 seconden lang en op intervallen van 15 minuten worden uitgevoerd.
1. Draai de functiedraaiknop naar µA
, mA
of A
, de corresponderende meeteenheid zal op de display verschijnen.
2. Druk kort op de toets SEL om te kiezen uit “DC”, “AC”, “Hz”.
3. Sluit de testkabels aan op de aansluitklemmen:
- Rode testkabel op aansluitklem
.
- Zwarte testkabel op aansluitklem COM of 10A max.
4. Sluit de testkabels in serie aan op het circuit.
5. Lees de waarde af op de display.
- Gelijkstroom DC: De polariteit wordt samen met de gemeten waarde weergegeven.
- Wisselstroom AC: Waarden worden uitgedrukt in echte RMS.
- Frequentie:�Het�meetbereik�is�40�tot�400�Hz�(ingangsamplitude�≥�bereik�×�50�%).
6. Koppel de testkabels na de meting los, schakel het circuit uit en schakel de DMM UIT.
600mA max
FUSED
600V max
10A max
FUSED
600V max
MAX 30sec EACH 15min
-
+
12. Aanvullende functies
Toets indrukken:
Kort indrukken = <2 sec.
Lang indrukken = >2 sec ingedrukt houden.
a) Subfuncties openen
Er zijn verschillende meetfuncties toegewezen aan subfuncties, gemarkeerd in het rood rondom de functiedraaiknop.
Druk kort op de toets SEL om alle subfuncties te doorlopen.
b) Bereik
Druk op de toets RANGE om de DMM te wisselen tussen automatisch “Auto” bereik en handmatig bereik.
Deze modus geldt alleen voor de volgende functies: V
, V
, Ω, Hz, µA
, mA
en A
.
• Handmatige bereikmodus openen: Druk kort op de toets RANGE.
- “Auto” zal uit de display verdwijnen.
- Druk kort op RANGE om de bereiken te doorlopen (aangegeven door de decimaalpositie).
• Handmatige bereikmodus verlaten: Druk lang op de toets RANGE of draai de functiedraaiknop, “Auto” zal op de
display verschijnen.
c) Houd
De houdfunctie behoudt de aangegeven waarde op de display, zodat u meer tijd hebt om de waarde af te lezen en
te noteren.
Als u stroomgeleidende draden test, zorg er dan voor dat deze functie is gedeactiveerd voordat u begint
met de meting. De meting zal anders incorrect zijn.
• Druk kort op de toets HOLD om de houdfunctie te activeren/deactiveren.
• Het symbooltje
zal verschijnen om aan te geven dat de houdfunctie actief is.
d) Piek
• U kunt met deze functie snellere signaalgebeurtenissen meten dan de normale min/max-functie.
Ingangsveranderingen van 1 milliseconde of langer zullen worden vastgelegd.
• Deze modus is alleen beschikbaar voor de volgende functies: V
, mV
, µA
, mA
en A
.
• Druk lang op de toets PEAK om de piekwaardemodus te openen/verlaten.
• Druk kort op de toets PEAK om de “P-MAX”- en “P-MIN”-waarden te doorlopen.
e) Maximum / minimum
U kunt met deze functie de maximale of minimale waarden tijdens een serie metingen opslaan en weergeven. Het
automatische bereik zal worden gedeactiveerd.
• Deze modus geldt alleen voor de volgende functies: LOZV
, LPFV
, V
, V
, mV
, Ω, µA
, mA
, A
en
°C/°F.
• Selecteer het juiste bereik voordat u MAX MIN selecteert, om ervoor te zorgen dat de MAX MIN-lezing het
meetbereik niet overschrijdt.
• De waarden worden gemeten vanaf het moment dat de MAX MIN-modus was geopend. Ingangsveranderingen
van 100 milliseconden of langer zullen worden vastgelegd.
• Druk lang op de toets MAX MIN om de maximum en minimum meetmodus te openen/verlaten.
• Druk kort op de toets MAX MIN om de metingen te doorlopen:
- Maximum waarde: MAX zal op de display worden weergegeven.
- Minimum waarde: MIN zal op de display worden weergegeven.
f) Automatische uitschakeling
De automatische uitschakeling is een energiebesparende functie. Wanneer geactiveerd, dan zal het apparaat
uitschakelen nadat er ongeveer 15 minuten lang geen activiteit wordt waargenomen. Druk op een willekeurige toets
of draai de functiedraaiknop om het apparaat te wekken.
1Automatische uitschakelfunctie deactiveren
1. Draai de functiedraaiknop naar de stand OFF.
2. Houd de toets SEL/PEAK ingedrukt en draai de functiedraaiknop tegelijkertijd naar een willekeurige positie.
3. Het symbooltje
zal verdwijnen.
2Automatische uitschakelfunctie activeren
• Herstart het apparaat door de functiedraaiknop naar OFF en weer naar ON te draaien.
• Het symbooltje
zal worden weergegeven.
g) Automatisch achtergrondlicht
Wanneer de helderheid van de omgevingsverlichting verlaagt tot onder een bepaalde drempelwaarde, dan zal het
achtergrondlicht automatisch AAN schakelen (tijdsduur: 30 seconden). Het achtergrondlicht schakelt automatisch UIT
wanneer de omgeving helder genoeg is.