ViM TEDH F400 Technical Manual
| Brand: | ViM |
| Category: | Fan |
| Model: | TEDH F400 (Technical Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 48 |
Text of ViM TEDH F400 Technical Manual
INSTALLATION | CONNECTION| COMMISSIONING | MAINTENANCE |
AFNOR CERTIFICATION
ISO 14001
Environnement
AFNOR CERTIFICATION
ISO 9001
Q u a l i t é
TEDH F400 ECOWATT®
TEDV F400 ECOWATT®
Roof Fan F400-120 (400°C 120 min)
EC Motor
GENERAL ........................................................................................................................................... 3
1.1
Disclaimers ............................................................................................................................... 3
1.2
Safety instructions ......................................................................
This product has been manufactured according to rigorous technical rules of safety in conformity with EC
standards. The EC declaration may be downloaded from the Internet site (address given on the last page).
Before installing and using this product, carefully read these instructions, which contain important indica-
tions for your safety and the user’s safety during the
ViM TEDH F400 1.3 Acceptance – Storage
In case of missing items or delivery of non conforming, partially or totally damaged products, the Buyer
shall make, in accordance with article 133-3 of the French Commercial Code, reservations in writing on the
transporter�receipt�and�confirm�them�within�seventy-two�(72)�hours�by�registered�letter�along�with�a�copy�
addressed to the seller.
TED ECOWATT® type
Running mode
Electrical accessories*
VAV
Manual - Internal potentiometer
Included in the controller
VAV
Manual - External input
CVF/REB ECOWATT®/0-10V external input/
BMS ModBus
VAV
Manual - 2 speeds
BCCA 2S/VRPZ
VAV
Slave mode according to external input
Sensors
VAV
Regulation according to internal potentiome-
ter�setting�point/external�value�difference
Setting point: in
2 x B
To avoid injurying people or damaging the equipment, use handling devices in conformity and in good
condition.
The roof fan must be lifted with 4 lifting lugs.
Use slings with lengths greater than or equal to twice roof fan height. The caps must be removed before
slinging (see § "3.4 Removing the caps"). Make sure that the slings do not rub against the dome. If in
doubt, remove t
ViM TEDH F400 3.3 Mounting roof fan accessories
TCDZ01
TCDZ05*
TCDZ03
TCDZ03
TEDH F400 ECOWATT ®
TEDV F400 ECOWATT®
TDCZ06
SIL
POPM
KRVT
(TEDH)
TCDZ 14
(TEDV)
TCDZ 15
(TEDH)
TCDZ 04
TCDZ 07
TCDZ 02
TCDZ 09
or
or
or
or
or
or
TCDZ08
* : Some adaptation plate diameters are not compatible with the following accessories: TCDZ 02, 04, 07 and 08 (see § "3.3.4
Adaptation plate : TCDZ 05").
TCDZ08
ViM TEDH F400 3.3.1 Standard support: TCDZ 01
This�assembly�does�not�allow�using�an�energy�save�flap�or�an�adaptation�plate.�Make�sure�that�the�duct�
can withstand the roof fan weight.
B
C
325mm mini
A
• Install the 4 angle brackets B and the 2 hose
clamps C on the duct.
• Install the seal A on the duct’s free edge.
• Put the roof fan on the duct by centring it cor-
r
3.3.4 Adaptation plate : TCDZ 05
G
E
ØD
T
The adaptation plate allows connecting roof fan
to a circular duct. Since it is designed to make the
air connection, it is not supposed to withstand roof
fan weight. This is incompatible with the use of the
energy�saver�flap�TCDZ�03�and�the�roof�adapter�
with sound attenuator TCDZ 09.
Model
Accessory size
Dimensions (mm)
Weight
(kg)
G
E
ViM TEDH F400 • Glue the foam seal on the support.
• Position the roof fan on the kit (pay particular
attention to the plate’s direction).
• Screw the 2 HM8x20 screws in the hinge’s
crimped nuts.
• Tie up the free chain extremity to the roof fan
plate with an HM8x16 bolt supplied.
• Lift the roof fan and immediately install the
safety bar and lock it with the safety pin.
• Glue the inst
ViM Fan Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
KUBAIR F400 |
Manual: ViM KUBAIR F400 (11E68C, Upd.24-05-2026) |
28 | 1351 | 203 | 24-05-2026 | |
TEDH F400 |
TEDH F400 Technical manual - 2E6W7T |
28 | 641 | 148 | 10-10-2026 | |
KDTA-R F400 |
#EQ5G6E: KDTA-R F400 Fan Instruction manual |
16 | 1354 | 285 | 21-08-2026 | |
TEDH F400 |
Fan #S5YC65 |
60 | 1357 | 258 | 18-08-2026 | |
JBRB ECOWATT PR |
User Guide: ViM JBRB ECOWATT PR (82N143, Upd.10-09-2026) |
48 | 209 | 49 | 10-09-2026 | |
TEDH F400 |
ViM Fan Technical manual (File: PDF, 19-08-2026) |
48 | 1207 | 194 | 19-08-2026 | |
KUBAIR F400 ECOWATT |
#OJ6NI7: KUBAIR F400 ECOWATT Fan Technical manual |
52 | 270 | 49 | 07-09-2026 | |
KUBAIR F400 ECOWATT CC |
KUBAIR F400 ECOWATT CC Technical manual - F2LMX4 |
44 | 192 | 41 | 22-06-2026 |