Planar IT-081 Operating Manual

Text of Planar IT-081 Operating Manual

TABLE OF CONTENTS

1. PRODUCT FAMILY GENERAL INFORMATION .............................................................. 4 2. GENERAL DESCRIPTION AND PRINCIPLE OF OPERATION....................................... 5 2.1. Introduction.................................................................................................................................................................................5 2.2. Safety Precautions.............................

1. PRODUCT FAMILY GENERAL INFORMATION

IT-08 is a multifunction handheld compact lightweight measurement instrument incorporating two components. One of the components, MB-08 Base Unit, remains invariable and provides color display, control and powering (from batteries or mains adapter) features. The other component, MC-08x, is one of the removable modules, which determine measurement functions of the whole instrument. IT-08 is capable to satisfy all your r

2. GENERAL DESCRIPTION AND PRINCIPLE OF OPERATION

2.1. Introduction This Operating Manual is intended for introducing the design, functions, and basic instructions related to operation and servicing of the IT-081 TV Level Meter (Meter). The IT-081 is designed for control and adjustment of television and broadcasting distribution networks as well as of separate components of such networks, or other electronic devices. The Meter allows measurement of channel

This Operating Manual is made in accordance with the hardware version 02.80.01 for

MB-08 Base Unit and software version 1.2.x.x/1.2.x.x for IT-081. 2.4. Environmental Conditions Normal operating conditions: a) ambient temperature (23±5) 0С; b) relative air humidity (55±25)%; c) atmospheric pressure 84-106 kPa (630-795 mm Hg); d) voltage transients correspond to installation category CAT. II. Rated operating conditions: a) ambient

Operating frequency range ...............................................................................5 to 900 MHz

Resolution.................................................................................................................125 kHz Channel allocation standard .................................... China, PAL B/G, PAL Ireland, PAL UK, .................................................................................. Secam

2.7. Design and Operation Overview

2.7.1. Principle of Operation The TV Level Meter is a super heterodyne receiver with triple frequency conversion (auto or manual frequency tuning). Channel power is measured by means of analog-to- digital converter (ADC) after signal peak detection at output of logarithmic detector of the amplifier of the third IF. The principle of spectrum analyzer is based on sequential analysis method with spectrum indication on the LC

Logarithmic Gain Amplifier Limiter (LGAL) performs logarithmation and signal

detection. Peak Detector (PD) allows measuring the video carrier level by means of Analog-to- Digital Converter (ADC). The digital code of the input signal peak level logarithm is defined as real value and is corrected in accordance with the calibration matrix of the Control Unit (CU) microcontroller. The Control Unit receives the commands from the user entered via Keypad, process

Planar Measuring Instruments Owners Instructions: