tell Adapter2 Installation And Application Manual
Read Online
Read the tell Adapter2 Installation And Application Manual online using the built-in PDF viewer.
Key Pages of Document
for device version v5.00 and newer Document version 5.0 04.09.2018 Product models: Adapter2 2G.IN4.R1 Adapter2 3G.IN4.R1 Adapter2 3GA.IN4.R1 Adapter2 4G.IN4.R1 Adapter2 4GA.IN4.R1 Adapter2 PRO 2G.IN4.R1 Adapter2 PRO 3G.IN4.R1 Adapter2 PRO 3GA.IN4.R1 Adapter2 PRO 4G.IN4.R1 Adapter2 PRO 4GA.IN4.R1 ...
1 Adapter2 operation .................................................................................................................... 4 1.1 Key functions of the Adapter2 ............................................................................................ 4 1.2 Under Voltage Lock Out (UVLO) function .......................................................................... 4 1.3 System overview ............................... ...
4.2.11 Advanced settings ....................................................................................................... 51 4.3 Device status menu .......................................................................................................... 53 4.3.1 Status monitoring ..................................... ...
1.1 Key functions of the Adapter2 The basic function of the Adapter2 is forwarding alarm control panel’s reports to remote monitoring station using GPRS/UMTS connection. Main functions: Sends SMS, e-mail* and Push notification* with configurable message for each event Reports events by SMS, e-mail* and Push notification*, by voice call with recordable message, over IP to remote monitoring stations using different communicat ...
The Adapter2 communicates with TELLMon receivers and TEX-MVP servers through the GSM service provider’s APN gateway using the GPRS/UMTS network, and then through the Internet. After processing and conversion, the server forwards the received data packages through serial port towards the monitoring PC that runs the alarm monitoring software. 1.4 Event sending and acknowledging The device sends the events simultaneously to the configu ...
2.1 Input wiring For the inputs, the normally closed or normally open dry contact should be connected between the given input (IN1…IN4) and the negative of the power input (V-) or the COM terminal. If a normally open dry contact is used to activate the input, choose the NO (normally open) option at the given input’s settings. In this case the input becomes activated when the given input (IN1…IN4) and the ...
circuit protections, the COM terminal shall not be used as negative input for powering the device, because this may damage the device! The COM terminal should only be used for connecting the contact inputs and the relay output! 2.3 SIM card socket The SIM card socket can be accessed by removing the cover of the aperture found on the device enclosure. The cover can ...
Disable voicemail and notification in SMS about missed calls on the SIM card installed into the device. The device can handle the SIM card’s PIN code. If you wish to use the PIN code management, configure the SIM card’s PIN code in the programming software at the “Device settings / General” section. Otherwise disable PIN code request on the SIM card. Enable caller identification service on the SIM card at th ...
The Adapter2 can be configured the following ways: By computer via USB, using the programming software. By computer over the Internet, using the programming software. The Adapter2 programming software is compatible with the following operating systems: Windows 10 (32/64 bit) Windows 8.x (32/64 bit) Windows 7 (32/64 bit) Installing the programming software: open the software setup application and follow the i ...
used by central monitoring stations that own a TELLMon receiver. Cloud: remote connection through the Internet via the cloud server operated by the manufacturer. Peer-to-peer: direct remote connection via the Internet. This option can be used if the computer running the programming software and the SIM card installed into the Adapter2 device are in the same VPN ...
This connection type can be used if the Adapter2 device you wish to connect remotely to, can use the cloud service. For this, the APN settings should be configured in the “General” settings menu and it is also necessary to have installed into the device a SIM card with available mobile Internet service which uses public APN, or, if using a private APN, accessing the cloud server IP address should ...
connection with the cloud server. In this case skip the SMS sending process mentioned below. Cloud usage can be enabled in the “General” settings menu. If cloud usage is disabled, the device will not keep continuous connection with the cloud server, it will only connect upon request. Therefore, if this is the case, before trying to connect remotely to the ...
configure these using the following SMS commands: SMS command Specification APN=APN,PWD=device password# Configuring the APN APN=APN,username,password,PWD=device password# Configuring the APN along with the username and password belonging to it CONNECT=server address:port nr,PWD=device password# Configuring the cloud server address and port numbe ...
This connection type can only be used in a private APN, or through a virtual private network (VPN) connected to the given private APN. In case of private APN, for the SIM cards in the given APN, sending and receiving data between each other should be enabled. The SIM card installed into the Adapter2 device you wish to connect remotely to, should have a static IP address and should be part of ...
This connection type can be used if the Adapter2 device you wish to connect remotely to, is connected to a TEX-MVP server. Also use this connection type if the Adapter2 device is connected to a TELLMon receiver and the device is configured to communicate with the TELLMon receiver using the TEX-MVP protocol. With this connection type, connection between the device and the Adapter2 pr ...
This connection type can be used if the Adapter2 device you wish to connect remotely to, is connected to a TELLMon receiver and the device is configured to communicate with the TELLMon receiver using the TELLMon protocol. With this connection type, connection between the device and the Adapter2 programming software can be established through the receiver on which the device is onlin ...
4.1 Connection menu 4.1.1 Viewing the settings options and configuring offline The Adapter2 programming software supports all Adapter2 device models, therefore the software shows the settings options available specifically in a given device model, which are different from the common parameters (e.g. differences between the PRO and non PRO device models) only when connecting the given device model, i.e. an A ...
In the “Connection type” menu the type of connection can be selected (USB or different options for connecting over the Internet), information can be seen about the connection process, and the admin and superadmin password can be changed. The default superadmin password is 1234. If you wish to use the admin level access as well, for this the password should be configured separately by clicking on the “Change Admin password” ...
If necessary, you can restart the connected device by clicking on this button. Restore factory default settings: By clicking on this button, you can restore the factory default settings in the device. Restoring the factory default settings will erase the actual settings, therefore please save your settings if needed. The reset process may take more than 1 minute and involves a device restart. Wait until the device restarts an ...
: save database to file : load database from file : add new device : clone entry (duplicate) : edit entry : delete entry Data stored by the device register: Device name: custom name SIM identifier (ICCID): the identifier of the SIM card inserted into the device (if the SIM card is inserted, the software reads the ID automatically from the device and inserts the data in this field when yo ...