MSA M1 Operating Manual
Text of MSA M1 Operating Manual
MSA Europe GmbH
Schlüsselstrasse 12
8645 Rapperswil-Jona
Switzerland
[email protected]
www.MSAsafety.com
© MSA 2019 All rights reserved
M1 Modular SCBA System
Contents
1
Safety Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1
Correct Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2
Liability Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M1 Modular SCBA System 1
Safety Regulations
1.1
Correct Use
The MSA M1 - referred to hereafter also as device - is a pressure-demand self-contained
breathing apparatus (SCBA) operating independent of the ambient air for use in firefighting in
atmospheres immediately dangerous to life or health.
In combination with a certified facepiece (full face mask) the device protects the wearer against
inhalation of hazardous substances and mix
M1 Modular SCBA System 1.3
Safety and Precautionary Measures
•
Approved for use at temperatures between -40 °C and +60 °C depending on facepiece certifi-
cation. For detailed information, see chapter 10.
•
The device may be used in potentially explosive atmospheres according to the class stated in
chapter 10.1.
•
The ATEX class of any other equipment used together with this device has to be regarded as
well. The lowest class
M1 Modular SCBA System 2
Description
The M1 SCBA is a pressure-demand self-contained open circuit breathing apparatus (SCBA)
operating independent of the ambient air for use in atmospheres immediately dangerous to life or
health.
Breathable air is supplied to the user from a compressed air cylinder via a pressure reducer, a
lung governed demand valve (LGDV) according to EN 137:2006 and a full face mask according
to EN 136:1998 (see operati
M1 Modular SCBA System Fig. 2
Example of M1 SCBA with SingleLine
1
Cylinder strap
6
Backplate
2
SingleLine
7
Handle
3
Cylinder buckle
8
Hip belt
4
Shoulder strap
9
Pressure reducer
5
Manifold (here SingleLine SCOUT)
1
3
4
5
6
7
8
9
2
M1 Modular SCBA System Fig. 3
System Overview (schematic representation)
1
2
2a
2b
2c
3
4a
4b
4g
5a
5b
6a
6b
7a
2d
7c
7b
4c
3a
3b
3c
4d
4e
4f
5c
8
4h
M1 Modular SCBA System The backplate consists of an anatomically designed plate of antistatic plastic with handles for easy
transport of the apparatus. The pressure reducer is located in the lower section of the backplate.
On the upper part of the backplate, a cylinder support is attached with integrated hose retainer.
The shoulder straps and the hip belt are adjustable in length.
One or two compressed air cylinders can be placed on the cy
M1 Modular SCBA System 2.2
Pneumatics
2.2.1 Pressure Reducer
The pressure reducer reduces the cylinder pressure to medium pressure, which will be further
reduced by the LGDV to a pressure that is respirable by the user. The pressure reducer incorpo-
rates a fail safe design which ensures air flow to the user in the event of a malfunction within the
pressure reducer.
The pressure reducer incorporates a medium pressure relief valve, and a c
M1 Modular SCBA System 2.2.2 Manifolds
Non-Electronic Configuration
Fig. 8
Combination gauge
Fig. 9
Standard manifold assembly
1
Pressure gauge
3
Warning whistle
2
Second connection (optional)
4
Lung governed demand valve coupling
1
Pressure gauge
3
Warning whistle
2
Lung governed demand valve coupling
3
4
2
1
1
2
3
M1 Modular SCBA System Electronic Configuration
Fig. 10
Overview SingleLine SCOUT
For more information, see SingleLine SCOUT operating manual.
1
Second connection (optional)
6
Battery life indication
2
Pressure gauge
7
Warning device (warning whistle)
3
Pressure gauge lightning
8
Lung governed demand valve coupling
4
Buddy lights
9
Alarm button
5
Sound channel & safety key holder with safety
key (left)
10
Data transmission active
1
2
3
4
MSA Firefighting Equipment Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | For Device |
|---|---|---|---|---|---|---|---|
M1 |
Guide: MSA M1 (EM38N4, Upd.25-04-2026) |
37 | 781 | 196 | 25-04-2026 | view all | |
Gallet F1 XF |
Gallet F1 XF (Firefighting Equipment ePDF Guide, #U4R28Z) |