MSA M1 Operating Manual
| Brand: | MSA |
| Category: | Control Unit |
| Model: | M1 (Operating Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 22 |
Text of MSA M1 Operating Manual
M1 Control Module
Integrated Personal Alert Safety System (PASS)
Order No.: 10205429/00
M1 Control Module 3
GB
Contents
1
Safety Regulations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1
Correct Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2
Liability Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M1 Control Module 4
Safety Regulations
GB
1
Safety Regulations
1.1
Correct Use
The M1 Control Module, in this manual also referred to as device, is a personal monitoring unit that
monitors the proper functioning of a respiratory protective device. It displays the current operating data
of the respiratory protective device and signals danger conditions (visually and acoustically).
It is imperative that this operating manual be read and observed when using t
M1 Control Module 5
Description
GB
2
Description
Fig. 1
Overview M1 Control Module
The M1 Control Module (see Fig. 1) is connected at the end of the high pressure gauge line of an appli-
cable MSA SCBA.
The device monitors the proper functioning of the respiratory protective device and signals danger
conditions (visually and acoustically). The digital display shows the current operating data of the respi-
ratory protective device, especially the pressure
M1 Control Module 6
Installation
GB
3
Installation
Installations can only be done by certified MSA technicians outside of hazardous areas.
4
Use
4.1
Before Use
Before using the device, it is recommended to perform a short check to test for any leakage in the
system.
(1)
Open compressed air cylinder.
(2)
When device is started, close compressed air cylinder.
(3)
Double press the alarm button.
4.2
Switching on
(1)
Open compressed air cylinder.
If pressure <