CUB4TC - Thermocouple types T, E, J, K, R, S, B, N, or mV CUB4RT - RTD types Pt385, Pt392, Ni672, Cu427 ! PROGRAMMABLE TEMPERATURE OFFSET ! SELECTABLE F or C WITH 1 or 0.1 RESOLUTION ! F OR C DISPLAY ANNUNCIATORS ! CONFORMS TO ITS-90 TEMPERATURE SCALE ! COLD JUNCTION COMPENSATION (Enable/Disable) CUB4TC ! 0.48 INCH (12.2 mm) HIGH DIGI ...
Input Impedance: 20 MΩ Lead Resistance Effect: 0.03µV/ohm Maximum Input Voltage: 30 VDC, TC+ to TC- Maximum Input Voltage TC-: 3 VDC max. with respect to common CUB4RT RTD Inputs: Lead Resistance: Cu427: 3 ohms/lead, 6 ohms total All others: 10 ohms/lead, 20 ohms total Balanced Lead Resistance: Autom ...
cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that power supplied to the unit be protected by a fuse or circuit breaker. Unit should be mounted in a relatively stable temperature environment. Av ...
This program item sets the display for Fahrenheit or Celsius and whole number or tenths. Tenths is not available for thermocouple types R, S, and B. To change the display, use the “blank” button to scroll through the list of choices. Press the “SEL” button to enter the choice and return to the main menu. This menu item doe ...
Resistance Calibration Diagram 1. Connect a precision Voltage Source with an output range of 0.000 to 105.000 mV and an accuracy of 0.03% or better to the SIG+ (#3) and SIG- (#5) terminals. Placement of jumper does not affect voltage calibration. 2. Enter the Program Menu and step through the Program Menu list by pressing the � ...
mV and an accuracy of 0.03% or better to the TC- (#5) and TC+ (#3) terminals. Cold junction calibration must be performed AFTER voltage calibration. 2. Enter the Program Menu and step through the Program Menu list by pressing the “SEL” button until CAL i ...
when properly installed. The units are intended to be mounted on an enclosed panel. The viewing window and buttons are factory sealed for a wash down environment. A sponge rubber gasket and mounting clip are provided for sealing the unit in the panel cut-out. Installation Environment Th ...
for a period limited to one year from the date of shipment, provided the products have been stored, handled, installed, and used under proper conditions. The Company’s liability under this limited warranty shall extend only to the repair or repla ...
⚠️ Download Safety
The Measuring Instruments Manual (8 pages) is completely safe to download (last scan date: 27/08/2026).
Related PDF Instructions for red lion CUB4RT:
-
red lion RLSP-100 Water Pump Manual , 20 pages
-
red lion RAM-6021 Network Router Hardware and installation manual, 15 pages
-
red lion PAXLA Measuring Instruments Operation & user’s manual, 12 pages
-
red lion RL-SPBS Water Pump Owner's manual, 48 pages
-
red lion CUB2L Cash Counter Manual , 2 pages
-
red lion ITMA Series Media Converter Product manual, 18 pages