Opticon MDL-1000 Software Manual
Text of the manual
MDL – 1000 / 2000
Specification for Software Interface
Laser Scan Engine with Built-in Decoder
Document:MDL-1000/2000 Specification for Software Interface
Admin No.: Publication.No. DM-0511015 / Doc.Control.No. SW06001 / Edition: 3rd Revision
Collected: OPTOELECTRONICS CO.,LTD, Tsukagoshi, Saitama Pref.
Distributed: Opticon Sensors Europe B.V., Hoofddorp
CAUTION: This information is subject to change without
TABLE OF CONTENTS
1.
ABSTRACT ...........................................................................................................7
2.
OVERVIEW............................................................................................................8
3.
INTERFACE.................................................
Table of Parameters.............................................................................................42
5-2
Common Elements to All Parameters ............................................
UPC-A Preamble (0x22).......................................................................................79
8-19-4
Enable/Disable UPC-E (0x02) ...........................................................................80
8-19-5
Transmit UPC-E Check Digits (0x29)...............................................
MSI Plessey Check Digit Algorithm (0x33).........................................................124
8-27
RSS (Reduced Space Symbology) ....................................................................125
8-27-1
Enable/Disable RSS-14 (0xF0 0x52) .................................................................
This specification provides interface specifications of an X1 laser scan engine with a built-in decoder
(“X1” is a tentative name of this product. This product shall be hereinafter called as “this scan
engine”).
This scan engine is a compact laser scan engine with a built-in decoder, which is possible to be
installed in various handheld products such as handy terminals.
The host system controls this scan engine and inputs scanned data in serial communication.
This material provides information on the control method
Signals used to connect this scan engine and host system are as follows:
Signal
Input/Output
Function
Notes
RXD
Input
Serial Receive Data
TXD
Output
Serial Transmit Data
CTS
Input
Clear To Send
Request for the host system to transmit the
data at L-level
RTS
Output
Request To Send
Feasi