Queclink GL300 Operation & User’s Manual

Text of Queclink GL300 Operation & User’s Manual

GL300A Manage Tool User Guide

TRACGL300AMT001 - 1 - Document Title GL300A Manage Tool User Guide Version R1.00 Date 2017-11-01 Status Release Document Control ID TRACGL300AMT001 General Notes Queclink offers this information as a service to its customers, to support application and engineering efforts that use the products designed by Queclink. The information provided is based upon requir
GL300A Manage Tool User Guide TRACGL300AMT001 - 2 - Contents Contents ........................................................................................................................... 2 0. Revision History ............................................................................................................. 3 1. GL300A Manage Tool Interface.................................
GL300A Manage Tool User Guide TRACGL300AMT001 - 3 - 0.Revision History Revision Date Author Description of Change 1.00 2017-11-01 Willie Liu Initial Queclink Confidential
GL300A Manage Tool User Guide TRACGL300AMT001 - 4 - 1.GL300A Manage Tool Interface GL300A Manage Tool is PC software which can be used to configure GL300A through UART. It is easy for the backend server developers to configure GL300A with Manage Tool which has friendly user interface. The correct command messages sent to GL300A will be displayed on the Manage Tool. (These messages can also
GL300A Manage Tool User Guide TRACGL300AMT001 - 5 - 1.2.COM Setting Select the COM port and baud rate (115200bps by default), input the password (“GL300A” by default), and click “OK” button, then setting window will be displayed. It is strongly recommended to disconnect COM port before removing the device. 1.3.Quick Setting Wizard The Quick Setting Wizard provides basic settings fo
GL300A Manage Tool User Guide TRACGL300AMT001 - 6 - 1.4.Professional Setting Windows 1.4.1.Title Bar Title Bar indicates current command title and the name of the Manage Tool. 1.4.2.Menus There are “Start”, “Tool”, and “Help” in menus. 1.4.2.1 Start Menu Start menu includes “COM Settings”. [COM Setting]: It is used to set the COM information and password. For Setting detail
GL300A Manage Tool User Guide TRACGL300AMT001 - 7 - [Operation Log]: It is used to display/hide the operation log. [Options]: It is used to set the basic settings of the Manage Tool. “Basic Options” includes startup setting options and log save option. “Advanced Options” includes COM settings and other settings. COM Settings is used to set COM setting. It is recommended to use defa
GL300A Manage Tool User Guide TRACGL300AMT001 - 8 - 1.4.2.3 Help Menu [About]: Select “About”. Then the following pop up window will be displayed. “Manage Tool Version” indicates the version of this Manage Tool. “Support Version” indicates the firmware which this Manage Tool is used for. “Device Version” indicates the firmware which connects to PC. It is recommended to use
GL300A Manage Tool User Guide TRACGL300AMT001 - 9 - 1.4.3.Toolbar It includes “COM Setting”, “Operation Log”, “Quick Setting Wizard”, “Real All Configuration”, “Send All Configuration” , “Save All Configuration”, and “Connect/Disconnect to COM”. [COM Setting]: It is used to set the COM information and password. For Setting details, please refer to Chapter 1.2. [
GL300A Manage Tool User Guide TRACGL300AMT001 - 10 - 1.4.5.1 Command Brower Command Brower divides all @track protocol commands into several parts. Click Function in command Brower, parameters of this command will be shown in Command Operation Space. Command Brower Function Description Related Command Server Connection Bearer Setting Information GTBSI Backend Server Registration Informatio
GL300A Manage Tool User Guide TRACGL300AMT001 - 11 - 1.4.5.2 Command Operation Space [Command Description]: There is a short description for the command. [Parameters Area]: Set/Read parameters of this command in this area. [Command Display]: Command with parameters in parameters area is displayed in this area. [Read]: Click this button to read this command from the device. [Send]: Click th
GL300A Manage Tool User Guide TRACGL300AMT001 - 12 - 1.5.2.Operation Failed Interface There should be something wrong with COM port connection if the failure reason is timeout. There should be COM port that is occupied. Please close all other COM-related applications. Please change to correct device password if Password Error occurs. There are some issues with this COM. Please check your c
GL300A Manage Tool User Guide TRACGL300AMT001 - 13 - 2.Operation Instruction 2.1.Device Configuration with Quick Setting Wizard The Manage Tool is developed based on the @Track Air Interface Protocol. Please refer to “GL300A @Track Air Interface Protocol” for details. The Quick Setting Wizard provides basic settings for the device. If you want to use more functions of GL300A, please ch
GL300A Manage Tool User Guide TRACGL300AMT001 - 14 - 2.1.3.Main Server Setting Step_1: Set report mode, main server, main server port, and SMS gateway in this window. For the meanings of these parameters, please refer to the “GL300A @Track Air Interface Protocol”. Step_2: Click “Check if main backend server is available” to check if main server IP and port are valid in network. If
GL300A Manage Tool User Guide TRACGL300AMT001 - 15 - 2.1.4.Fixed Time Report Setting Step_1: Set check interval, send interval, and discard no fix in this window. For the meanings of these parameters, please refer to the “GL300A @Track Air Interface Protocol”. Step_2: Click “Next”. Step_1 Step_2 Step_3 Queclink Confidential
GL300A Manage Tool User Guide TRACGL300AMT001 - 16 - 2.1.5.Send Command to Device Step_1: Click “Send Command”. The commands GTBSI, GTSRI, and GTFRI will be sent to the device. Step_2: If the settings are downloaded successfully, the result returns OK. Click “OK”, the result window is closed. Quick setting is completed. Step_1 Step_2 Queclink Confidential