Queclink GL300 Operation & User’s Manual
Text of Queclink GL300 Operation & User’s Manual
GL300A Manage Tool User Guide
TRACGL300AMT001 - 1 -
Document Title
GL300A Manage Tool User Guide
Version
R1.00
Date
2017-11-01
Status
Release
Document Control ID
TRACGL300AMT001
General Notes
Queclink offers this information as a service to its customers, to support application and
engineering efforts that use the products designed by Queclink. The information provided is
based upon requir
GL300A Manage Tool User Guide TRACGL300AMT001 - 2 -
Contents
Contents ........................................................................................................................... 2
0. Revision History ............................................................................................................. 3
1. GL300A Manage Tool Interface.................................
GL300A Manage Tool User Guide TRACGL300AMT001 - 3 -
0.Revision History
Revision
Date
Author
Description of Change
1.00
2017-11-01
Willie Liu
Initial
Queclink
Confidential
GL300A Manage Tool User Guide TRACGL300AMT001 - 4 -
1.GL300A Manage Tool Interface
GL300A Manage Tool is PC software which can be used to configure GL300A through UART. It is
easy for the backend server developers to configure GL300A with Manage Tool which has friendly
user interface. The correct command messages sent to GL300A will be displayed on the Manage
Tool. (These messages can also
GL300A Manage Tool User Guide TRACGL300AMT001 - 5 -
1.2.COM Setting
Select the COM port and baud rate (115200bps by default), input the password (“GL300A” by
default), and click “OK” button, then setting window will be displayed. It is strongly
recommended to disconnect COM port before removing the device.
1.3.Quick Setting Wizard
The Quick Setting Wizard provides basic settings fo
GL300A Manage Tool User Guide TRACGL300AMT001 - 6 -
1.4.Professional Setting Windows
1.4.1.Title Bar
Title Bar indicates current command title and the name of the Manage Tool.
1.4.2.Menus
There are “Start”, “Tool”, and “Help” in menus.
1.4.2.1 Start Menu
Start menu includes “COM Settings”.
[COM Setting]: It is used to set the COM information and password. For Setting detail
GL300A Manage Tool User Guide TRACGL300AMT001 - 7 -
[Operation Log]: It is used to display/hide the operation log.
[Options]: It is used to set the basic settings of the Manage Tool.
“Basic Options” includes startup setting options and log save option.
“Advanced Options” includes COM settings and other settings.
COM Settings is used to set COM setting. It is recommended to use defa
GL300A Manage Tool User Guide TRACGL300AMT001 - 8 -
1.4.2.3 Help Menu
[About]: Select “About”. Then the following pop up window will be displayed.
“Manage Tool Version” indicates the version of this Manage Tool.
“Support Version” indicates the firmware which this Manage Tool is used for.
“Device Version” indicates the firmware which connects to PC. It is recommended to
use
GL300A Manage Tool User Guide TRACGL300AMT001 - 9 -
1.4.3.Toolbar
It includes “COM Setting”, “Operation Log”, “Quick Setting Wizard”, “Real All Configuration”,
“Send All Configuration” , “Save All Configuration”, and “Connect/Disconnect to COM”.
[COM Setting]: It is used to set the COM information and password. For Setting details, please
refer to Chapter 1.2.
[
GL300A Manage Tool User Guide TRACGL300AMT001 - 10 -
1.4.5.1 Command Brower
Command Brower divides all @track protocol commands into several parts. Click Function in
command Brower, parameters of this command will be shown in Command Operation Space.
Command Brower
Function Description
Related Command
Server Connection
Bearer Setting Information
GTBSI
Backend Server Registration Informatio
GL300A Manage Tool User Guide TRACGL300AMT001 - 11 -
1.4.5.2 Command Operation Space
[Command Description]: There is a short description for the command.
[Parameters Area]: Set/Read parameters of this command in this area.
[Command Display]: Command with parameters in parameters area is displayed in this area.
[Read]: Click this button to read this command from the device.
[Send]: Click th
GL300A Manage Tool User Guide TRACGL300AMT001 - 12 -
1.5.2.Operation Failed Interface
There should be something wrong with COM port connection if the failure reason is timeout.
There should be COM port that is occupied. Please close all other COM-related applications.
Please change to correct device password if Password Error occurs.
There are some issues with this COM. Please check your c
GL300A Manage Tool User Guide TRACGL300AMT001 - 13 -
2.Operation Instruction
2.1.Device Configuration with Quick Setting Wizard
The Manage Tool is developed based on the @Track Air Interface Protocol. Please refer to
“GL300A @Track Air Interface Protocol” for details.
The Quick Setting Wizard provides basic settings for the device. If you want to use more
functions of GL300A, please ch
GL300A Manage Tool User Guide TRACGL300AMT001 - 14 -
2.1.3.Main Server Setting
Step_1: Set report mode, main server, main server port, and SMS gateway in this window. For
the meanings of these parameters, please refer to the “GL300A @Track Air Interface Protocol”.
Step_2: Click “Check if main backend server is available” to check if main server IP and port are
valid in network. If
GL300A Manage Tool User Guide TRACGL300AMT001 - 15 -
2.1.4.Fixed Time Report Setting
Step_1: Set check interval, send interval, and discard no fix in this window. For the meanings of
these parameters, please refer to the “GL300A @Track Air Interface Protocol”.
Step_2: Click “Next”.
Step_1
Step_2
Step_3
Queclink
Confidential
GL300A Manage Tool User Guide TRACGL300AMT001 - 16 -
2.1.5.Send Command to Device
Step_1: Click “Send Command”. The commands GTBSI, GTSRI, and GTFRI will be sent to the
device.
Step_2: If the settings are downloaded successfully, the result returns OK. Click “OK”, the result
window is closed. Quick setting is completed.
Step_1
Step_2
Queclink
Confidential