Lippert Components THROUGH FRAME ELECTRIC Troubleshooting
| Brand: | Lippert Components |
| Category: | Bicycle |
| Model: | THROUGH FRAME ELECTRIC (Troubleshooting) |
| File Type: | |
| File Size: | — |
| Pages: | 3 |
Text of Lippert Components THROUGH FRAME ELECTRIC Troubleshooting
THROUGH FRAME ELECTRIC
SLIDE-OUT TROUBLESHOOTING
What Is Happening?
Why?
What Should Be Done?
Room doesn't move when
switch is pressed.
Restriction or obstruction inside or
outside of unit
Check for and clear obstruction.
Low battery voltage, blown fuse,
defective wiring.
Check battery voltage and charge
if needed. Find and check fuse,
replace if blown. Check battery
terminals and wiring. Look for
loose, disconnected or corroded
co
THROUGH FRAME ELECTRIC SLIDE-OUT TROUBLESHOOTING
Manual Override
NOTe: Always disconnect battery from system prior to manually operating system. Failure to disconnect
battery can cause electricity to backfeed through the motor and cause serious damage to the
system as well as void the warranty.
The Through Frame Electric Slide-out System comes with a Manual Override system. There are two different
methods for manually extending an
THROUGH FRAME ELECTRIC SLIDE-OUT TROUBLESHOOTING
Manual Override - Inside Frame
Locate the hex head crank extension at the top of the actuator inside the chassis main frame (Fig. 3). Using a
3/4" socket and ratchet (Fig. 4), rotate the extension clockwise to retract the slide-out and counter clockwise
to extend the slide-out. It is important to note that you DO NOT need to attempt to disengage the motor as
the actuator is “manual