Nortroll ComTroll 230 Operation & User’s Manual
File Specifications
| Brand: | Nortroll |
| Category: | Controller |
| Model: | ComTroll 230 (Operation & User’s Manual), prHgSCuE1pZJg |
| File Type: | |
| File Size: | — |
| Pages: | 11 pages |
Download PDF
Download Nortroll ComTroll 230 Manual (11 pages)Read Online:
Read the Nortroll ComTroll 230 Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
It also covers the –T and –S versions. CLOSE OPEN SERVICE RESET TX RX CLOSED OPEN SERVICE NORTROLL AS RTU-30 CRU-200 COMMUNICATION MODULE SLC-200+ POWER MODULE LOCAL REMOTE OFF NORTROLL AS NORTROLL AS REMOTE CLOSE OPEN SERVICE RESET TX RX CLOSED OPEN SERVICE NORTROLL AS RTU-30i LOCAL OFF ...
COMTROLL 230, REMOTE TERMINAL UNIT ........................................................................................... 4 COMMUNICATION................................................. ...
The ComTroll 230 is designed for a complete and modular functionality for monitoring and control of primary and secondary functions in the distribution network. The rack-mounted system can control and monitor a wide range of objects such as pole- mounted sectionalizers, breakers, earthing switches, relay protection, ...
open/close button and the ModeSwitch (Remote/Off/Local) are removed. Each RTU-30 /RTU-30i has dedicated OPEN and CLOSE outputs with accompanying open and closed limit-switch inputs to ensure reliable operation. Details about the RTU-30 /RTU-30i functions and options ...
configurations with up to three RTU cards. (With radio communication only). SLC-200+ is the standard DC/DC regulator where external 12Vdc is available. This is also a battery charger for the backup battery, both when external DC is connected and w ...
Pin 1 is located in the upper left corner of J3. F1: Connects the Low Battery signal from SLC-200+ to Digital Input 1 on the NTM-20/25 Modem. Only used in repeaters. Default set open. F2: Connects either External DC input or the Battery Input to the Analog Input 4 on the first RTU-30 card. Ba ...
12 Vdc GND I2C TP-Net The backplane for additional RTU-30 cards have the same connectors and pin-out as the main backplane. ComTroll 230T Installing the TSU-25 Before powering the TSU-25, connect the antenna to the connector located on the front panel. The GPS antenna needs to be located with a good clear 360 degree view of the sky. ...
thumb, the better the view the antenna has of the sky, the better the signal locks and a good continuous uninterrupted time signal is provided. TSU-25 can only be used together with RTU-30t. When more than one RTU-30t card is installed in the same rack, a Router Mo ...
If the GPS receiver is not able to establish contact with the satellites, the TSU-25 will see that the attempt to download accurate time information failed. When the next sync period expires, the Status-LED will start flashing together with the Sync- LED. The Status-LED will stop flashing when the satellite contact is esta ...
⚠️ Download Safety
The Controller Operation & user’s manual (11 pages) is completely safe to download (last scan date: 24/05/2026).
Related PDF Instructions for Nortroll ComTroll 230:
-
Nortroll LineTrol R400D Measuring Instruments Operation & user’s manual, 32 pages
-
Nortroll LINETROLL 111K Test Equipment Operation & user’s manual, 2 pages
-
Nortroll LineTroll 110Em Measuring Instruments Operation & user’s manual, 16 pages
-
Nortroll ComTroll 230 Controller Operation & user’s manual, 11 pages
-
Nortroll CableTroll 210 Touch Panel Operation & user’s manual, 16 pages