Michell Instruments Optidew Operation & User’s Manual
| Brand: | Michell Instruments |
| Category: | Measuring Instruments |
| Model: | Optidew (Operation & User’s Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 66 |
Text of Michell Instruments Optidew Operation & User’s Manual
Michell Instruments Optidew Optidew & Optidew Vision
High Performance Optical
Dew-Point Transmitter
User’s Manual
97430 Issue 2
March 2017
Power On
Power Input
85-254 Vac 47-440Hz
Communications Port
Status
Temperature
Probe
Output Connections
Dewpoint
Sensor
Warning: Disconnect power
supply before removing cover
OPTIDEW
High Performance Optical Dew-point Transmitter
Display Control
Alarm/Dcc
OPTIDEW VISION
Precision Dewpointmeter
Michell Instruments Optidew Please fi ll out the form(s) below for each instrument that has been purchased.
Use this information when contacting Michell Instruments for service purposes.
Instrument
Code
Serial Number
Invoice Date
Location of Instrument
Tag No
Instrument
Code
Serial Number
Invoice Date
Location of Instrument
Tag No
Instrument
Code
Serial Number
Invoice Date
Location of Instrument
Tag No
© 2016 Michell Instruments
This document is the property of Michell Instruments Ltd. and may not be copied or
otherwise reproduced, communicated in any way to third parties, nor stored in any Data
Processing System without the express written authorization of Michell Instruments Ltd.
Optidew & Optidew Vision
For Michell Instruments' contact information please go to
www.michell.com
Michell Instruments Optidew Optidew Series User’s Manual
iv
97430 Issue 2, March 2017
Contents
Safety ................................................................................................................................vi
Electrical Safety ...........................................................................................................vi
Pressure Safety ............................................................................................................
Optidew Series User’s Manual Michell Instruments
v
Figures
Figure 1
Optidew .....................................................................................................2
Figure 2
Optidew Vision ...........................................................................................2
Figure 3
Sample Block ...........................................................................................12
Figure 4
Operating Cycle .....................
Optidew Series User’s Manual vi
97430 Issue 2, March 2017
Safety
The manufacturer has designed this equipment to be safe when operated using the procedures
detailed in this manual. The user must not use this equipment for any other purpose than that
stated. Do not apply values greater than the maximum value stated.
This manual contains operating and safety instructions, which must be followed to ensure the safe
operation and to maintain the equipment in
Optidew Series User’s Manual Michell Instruments
vii
Abbreviations
The following abbreviations are used in this manual:
AC
alternating current
aW
water activity - relative humidity on a scale of 0-1 with no units
atm
pressure unit (atmosphere)
barg
pressure unit (=100 kP or 0.987 atm) gauge
ºC
degrees Celsius
ºF
degrees Fahrenheit
∆ (t – tdp)
difference in ºC between ambient and dew-point temperature
DC
direct current
FAST
Frost Assurance System T
Optidew Series User’s Manual viii
97430 Issue 2, March 2017
INTRODUCTION
1
INTRODUCTION
The Optidew Series precision hygrometers are based on the proven, fundamental optical
dew-point measurement principle, giving long-term unmatched drift-free performance.
They offer a wide measurement range with a variety of sensor options to accommodate
almost any application.
Data Communication and Application Software
The Optidew Series provides two linear 4-20 mA
Optidew Series User’s Manual Michell Instruments
1
INTRODUCTION
1.1
Optidew Series
The Optidew Series is available in two variants, which differ only in enclosure type,
connectors and sensor cable:
Figure 1
Optidew
Figure 2
Optidew Vision
The Optidew features a rugged 304 stainless steel industrial enclosure, offering
protection to IP66 / NEMA 4x. The enclosure is suitable for wall mounting, and can be
ordered either as a blind transmitter or with an opt