Hunter PRO-C Hydrawise Software/app Owner's Manual

File Specifications

Brand: Hunter
Category: Irrigation System
Model: PRO-C Hydrawise (Software/app Owner's Manual), pr6jDcl9TOY9g
File Type: PDF
File Size: —
Pages: 15 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (15 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 10/07/2026).

Read Online

Read the Hunter PRO-C Hydrawise Software/app Owner's Manual online using the built-in PDF viewer.

Key Pages of Document

Table of Contents

Table of Contents HCC - Quick Start Guide HCC - Connecting AC Power HCC - Power Module Wiring Diagram HCC - Valve Wiring HCC - Installing ICM Station Modules HCC - Wire Distance to Valves HCC - Installing Wi-Fi Antenna Extension Kit Can Two Zones Run Simultaneously with a HCC controller? HCC - Configure Controller Off ...

HCC - Quick Start Guide

HCC - Connecting AC Power Connecting the controller to primary AC power should be done by a licensed electrician following all local codes. Install in approved conduit and fittings. The controller can operate with either 120VAC or 230VAC power. Supply wires must be 14AWG/ 2 mm2 or larger. IMPORTANT: If you are using the plug-in method ...

1. Turn AC power off at the source, and verify that it is off.

2. Disconnect the facepack ribbon cable 3. Remove the facepack. 4. Remove the cover from the junction box. Copyright 2021 Hunter Industries. All Rights Reserved. 4 ...

1. Strip about 0.5” (13 mm) of insulation from the end of each AC power wire.

2. Route the wires through the conduit opening inside the junction box. 3. Connect the incoming black power wire (HOT) with the black wire lead from the transformer. 4. Connect the incoming white wire (NEUTRAL) with the blue lead from the transformer. 5. Connect the incomi ...

EARTH GROUND CONNECTION (LIGHTNING PROTECTION)

1. Insert the copper wire from earth ground hardware, and tighten the screw in front. 2. Minimum 10 AWG/5mm2 wire to earth ground hardware. 3. Add copper-clad steel ground rods and/or plates sufficient to achieve 10Ω or less resistance at a minimum 8’/2.5 m away from the controller. HCC - Power Module Wiring ...

HCC - Valve Wiring

1. Route valve wires between control valve location and controller. 2. At valves, attach a common wire to either solenoid wire of all valves. The most commonly used color for the common wire is white. Attach a separate control wire to the remaining wire of each valve. All wire splice connections should be done using waterproof connectors. ...

HCC - Installing ICM Station Modules

The base model of HCC is supplied with an ICM-800 station output module. The capacity of the controller is increased when new station modules are installed and recognized. Standard ICM station modules are available in 4, 8, and 22 station sizes (ICM-400, ICM-800, ICM- 2200). These may be added at any time after initial in ...

Qty:4 - ICM-800

Qty:1 - ICM-2200 STEP 1 STEP 2 STEP 3 Open the controller inner panel, and choose the next available open slot in the controller. Slots are numbered, down the first column and up the second. Flip the blue locking lever into the vertical unlocked position. Tip the two tabs on one end of the module into the mating holes in one end ...

Below is a chart indicating the maximum wire run between the controller and the Hunter AC solenoid

valves. Valve Wire Sizing (Feet) Ground Control Wire 18 16 14 12 10 8 6 18 850 1040 1210 1350 1460 1540 1590 16 1040 1340 1650 1920 2150 2330 2440 14 1210 1650 2150 2630 3080 3450 3700 12 1350 1920 2630 3390 4170 4880 5400 10 1460 2150 3080 4170 5400 6670 7650 ...