Valcom V2006A Operation & User’s Manual
Text of the manual
V-2006A - INTEGRATED SIX ZONE PAGING CONTROL UNIT
V-2006AHF - INTEGRATED SIX ZONE HANDSFREE
TALKBACK PAGING CONTROL UNIT
"WARNING: To reduce the risk of fire or
electric shock, do not expose this equipment
to rain or moisture."
"WARNING: Shock Hazard - Do Not Open."
"AVIS: Risque de Choc Electrique ne pas
Ouvrir."
"PE
Electronic Key System (C. O. Line Position)
•
PABX (Loop or Ground Start Trunk)
•
1A2 Key Systems (400 Type Line Card required)
•
600 Ohms Page port equipped with contact
closure and DTMF dialing capability
•
Dedicated single line telephone
Additional Equipment Required
•
Backboard/mounting surface
•
25 pair cable with fem
Inhibit Option (Meet Me Answer)
The V-2006A/V-2006AHF is equipped with an inhibit
feature that automatically mutes output to the speakers
and allows a handset conversation between the paging
party and a single line telephone connected to the
paging Tip and Ring. A single line telephone modified
for "A" Lead Control and a 5.1K Ohm 1/4 Watt resistor
is requ
Connection of One-Way Amplified Speakers
See Figure 1, 66 Block Diagram.
NOTE: The V-2006A/V-2006AHF provides external
power of 30 power units (1.5 Amps of -24VDC) to
operate amplified speaker assemblies. Additional
power supplies are required for speakers using
power over the 30 power units. When using
additional power supplies, make certain:
1)
T
Zone 6 Auxiliary – K6 Relay
The V-2006A/V-2006AHF contains an auxiliary set of
make/break contacts which can be used to operate
mute contacts on a high powered amplifier or other
peripheral devices. Zone 6 dry contact closure
operates when Zone 6 is activated alone or in together
with a group call or all call. The contacts are rated at
1A @ 125 VAC or