Valcom V2006A Operation & User’s Manual

Text of the manual

V-2006A - INTEGRATED SIX ZONE PAGING CONTROL UNIT

V-2006AHF - INTEGRATED SIX ZONE HANDSFREE TALKBACK PAGING CONTROL UNIT "WARNING: To reduce the risk of fire or electric shock, do not expose this equipment to rain or moisture." "WARNING: Shock Hazard - Do Not Open." "AVIS: Risque de Choc Electrique ne pas Ouvrir." "PE

Electronic Key System (C. O. Line Position)

• PABX (Loop or Ground Start Trunk) • 1A2 Key Systems (400 Type Line Card required) • 600 Ohms Page port equipped with contact closure and DTMF dialing capability • Dedicated single line telephone Additional Equipment Required • Backboard/mounting surface • 25 pair cable with fem

Inhibit Option (Meet Me Answer)

The V-2006A/V-2006AHF is equipped with an inhibit feature that automatically mutes output to the speakers and allows a handset conversation between the paging party and a single line telephone connected to the paging Tip and Ring. A single line telephone modified for "A" Lead Control and a 5.1K Ohm 1/4 Watt resistor is requ

Connection of One-Way Amplified Speakers

See Figure 1, 66 Block Diagram. NOTE: The V-2006A/V-2006AHF provides external power of 30 power units (1.5 Amps of -24VDC) to operate amplified speaker assemblies. Additional power supplies are required for speakers using power over the 30 power units. When using additional power supplies, make certain: 1) T

Zone 6 Auxiliary – K6 Relay

The V-2006A/V-2006AHF contains an auxiliary set of make/break contacts which can be used to operate mute contacts on a high powered amplifier or other peripheral devices. Zone 6 dry contact closure operates when Zone 6 is activated alone or in together with a group call or all call. The contacts are rated at 1A @ 125 VAC or