Trumeter 7921 Manual
| Brand: | Trumeter |
| Category: | Relays |
| Model: | 7921 (Manual ) |
| File Type: | |
| File Size: | — |
| Pages: | 40 |
Text of Trumeter 7921 Manual
Trumeter 7921 018366-01 Issue 2 12/99
7921
6 digit programmable bi-directional counter relay, with
dual preset or batch mode operation, prescaling and
EEPROM data storage
6-Stelliger Bi-Direktionaler Zähler mit Supertwist-LCD
mit Einzel/Doppel- und Chargen Vorwahl, Skalierung
durch Vorteiler und EEPROM-Datenspeicherung
Relais de compteur bidirectionnel à 6 chiffres,
programmable, avec fonctionnement double en mode
automatique ou discontinu, génération d'échelles et
Black on green STN LCD, with yellow/green LED
backlight.
Program Storage
Erase/write cycles:1,000,000
Life: 40 years min
Count Range
-99999 to 999999
Count Pre-scaler
Multiplier 0.00250 to 9.99999
Divider 1 to 99999
External Reset response time
Max 2ms
Count Inputs
High Speed: 10kHz max (electronic)
(Dividing prescaler: 7kHz max)
Duty cycle: 60:40 max
Low Speed: 30Hz max (contact closure)
Relay Contacts
5A resistive load 100,000 opera
Trumeter 7921 multiplying prescaler value, or the unit may not operate correctly.
The P1 preset can be set at any time.
In Reset to Zero mode, the change will be accepted immediately.
In Reset to P1 mode, the change will not be accepted until after a Reset.
The P2 preset can be set as shown below.
The change will be accepted immediately.
Count Modes (see page 35)
The diagrams show how the P1 and P2 Relays are controlled by the Count, by Batch
Total and by Reset.
The dia
Connections (see pages 37 & 38)
Inputs A and B in Unidirectional mode
In the two Unidirectional modes, the count is incremented or decremented by input A,
whilst the direction is dependent on input B.
In Unidirectional High mode, both inputs are high speed inputs, suitable only for
electronic signal sources, eg. transistors, proximity switches, encoders.
In Unidirectional Low mode, both inputs are low speed inputs (30Hz max), suitable
for contact closure
Relays (see page 38)
The P1 and P2 relays can be programmed independently to be normally-open or
normally-closed. The contacts of a normally-closed relay will open when it operates, and
those of a normally-open relay will close.
The relays can be programmed independently to operate in pulsed or latched mode. In
pulsed mode (P1 relay: Auto Reset Off only) the relay will operate for a length of time set
by the program. In latched mode the relay will operat
If the Prescaler or the Reset Mode or the Batch Mode are changed, the new
configuration will not be fully effective until after exit from Program mode, AND THEN
AFTER a Reset.
Decimal Point
The decimal point can be in one of three positions, or off.
Prescaling
A multiplying or dividing factor can be used. If a multiplying prescaler of n is used, the
counter will count: 0, n, 2n, 3n etc. If a dividing prescaler of n is used, the counter will
increment or
Trumeter 7921 No Decimal point
1 Decimal place
2 Decimal places
3 Decimal places
Main menu
Prescaling
No prescaling
Multiply --------
Divide ----------
Main menu
P1 Relay Condition
Normally open
Normally closed
Main menu
P2 Relay Condition
Normally open
Normally closed
Main menu
P1 Relay Type
Pulsed ----------
Latched*
Main menu
P2 Relay Type
Pulsed ** ----------
Latched
Main menu
P1 Relay Safe State
Current state
Normal state
Operated state
Main menu
P2
Die beiden Tasten auf der Frontblende dienen zum Programmieren des Zählers sowie zum
Anzeigen und Einstellen der Vorwahlwerte P1 und P2. Alle Tasten können über den
Tastensperren-Eingang deaktiviert werden (siehe „Programmierung" auf S. 12).
Automatische Rücksetzung (siehe 1 und 3 auf S. 35)
Bei eingeschalteter automatischer Rücksetzung wird der Zähler wie folgt automatisch zurückgesetzt:
Im Modus „Auf Null zurücksetzen" wird der Zähler auf �
Trumeter 7921 jeweils grösser sein als der Wert des Prescaler-Multiplikators, da das Gerät sonst nicht
ordnungsgemäss funktioniert. Die Voreinstellung P1 kann jederzeit eingestellt werden.
Im Modus „Auf Null zurücksetzen" wird die Änderung sofort übernommen.
Im Modus „Auf P1 zurücksetzen" wird die Änderung erst nach einem Rücksetzen übernommen.
Die Voreinstellung P2 kann wie nachstehend beschrieben eingestellt werden.
Die Änderung wird sofort übernommen.
Anschlüsse (siehe S. 37 und 38)
Eingänge A und B im unidirektionalen Modus
In den beiden unidirektionalen Modi wird der Zählerwert durch Eingang A erhöht oder reduziert;
dabei bestimmt Eingang B die Zählrichtung.
Im Modus „Unidirektional hoch" fungieren beide Eingänge als Hochgeschwindigkeitseingänge, die
sich nur für elektronische Signalquellen wie Transistoren, Näherungsschalter, Codierer usw. eignen.
Im Modus „Unidirektional niedrig" fungie