Siemens LOGO! 0BA7 Manual 

File Specifications

Brand: Siemens
Category: Controller
Model: LOGO! 0BA7 (Manual ), prg1t5BVtgM56
File Type: PDF
File Size: —
Pages: 39 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (39 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 14/03/2026).

Read Online

Read the Siemens LOGO! 0BA7 Manual  online using the built-in PDF viewer.

Key Pages of Document

PI Controller for

Simple Applications - Optimum Motor Speed Control Simulated Application with S7-1200 for LOGO! and SINAMICS V20 Set 23 https://support.industry.siemens.com/cs/ww/en/view/23753479 Siemens Industry Online Support ...

Entry ID: 23753479, V2.3.S, 02/2014

2 © Siemens AG 2014 All rights reserved Legal information Use of application examples Application examples illustrate the solution of automation tasks through an interaction of several components in the form of text, graphics and/or software modules. The application examples are a free service by Siemens AG and/or a subsidiary of Siemens AG (“Siemens”). They are non- binding and ...

Table of Contents

Set23_RegSim Entry ID: 23753479, V2.3.S, 02/2014 3 © Siemens AG 2014 All rights reserved Table of Contents Legal information ..................................................................................................... 2 1 Task................................................................................................................. 4 1.1 Overview ....................................................................... ...

Entry ID: 23753479, V2.3.S, 02/2014

4 © Siemens AG 2014 All rights reserved 1 Task 1.1 Overview Introduction The features in the application will be explained with the example of an automation task so that they can be understood more easily. In an injection molding plant, the molded parts are cooled down to a certain final temperature by a water cooling system. Several water consumers are connected for cooling down up to three pa ...

Entry ID: 23753479, V2.3.S, 02/2014

5 © Siemens AG 2014 All rights reserved 2 Solution 2.1 Overview Schematic layout The following figure gives a schematic overview of the most important components of the solution: Figure 2-1 1 2 3 4 5 6 7 8 1 LOGO! Power 2 LOGO! logic module 3 LOGO! AM2 AQ 7 SIRIUS monitoring relay 5 SINAMICS V20 6 Asynchronous motor 8 Sensor for level monitoring 4 LOGO! TD 7 10 S7-1200 (PM, CPU, CSM) 10 11 ...

Entry ID: 23753479, V2.3.S, 02/2014

6 © Siemens AG 2014 All rights reserved integrated display of the LOGO! logic module, the setpoint pressure, the current pressure and the speed of the pump are displayed as bar diagrams. Advantages The solution presented here offers you the following advantages: • Cost-effective and stepless speed control • Simple combination of drive tasks with sensor and control functions by combining ...

Entry ID: 23753479, V2.3.S, 02/2014

7 © Siemens AG 2014 All rights reserved 2.3 Hardware and software components 2.3.1 Validity This Application is valid for: • LOGO! 0BA7 • SINAMICS V20 • STEP 7 as of V12 • S7-1200 2.3.2 Components used Note The cooling water system is designed for a 0.12 kW motor with a corresponding SINAMICS V20 frequency converter. Hardware components Table 2-1 No. Component No. Article number Not ...

Entry ID: 23753479, V2.3.S, 02/2014

8 © Siemens AG 2014 All rights reserved Configuration software/tools Table 2-3 Component No. Article number Note LOGO!Soft Comfort V7 1 6ED1058-0BA02-0YA1 2.4 Hardware and software components for the simulation of the controlled system Note With this component, it is possible to simulate the controlled system. The components listed here are needed in addition to the hardware listed in secti ...

Entry ID: 23753479, V2.3.S, 02/2014

9 © Siemens AG 2014 All rights reserved 2.5 Sample files and projects The following list includes all files and projects that are used in this example. Table 2-7 Component Note LOGO!Soft Comfort V7 – Program 23753479_Set23_RegSim_V23.lsc The zip-file contains: 23753479_Set23_RegSim_V23.zip STEP 7 V12 – Program 23753479_Set23_RegSim_V23.ap12 The zip-file contains: 23753479_Set23_RegSim_V ...

Entry ID: 23753479, V2.3.S, 02/2014

10 © Siemens AG 2014 All rights reserved 3 Operation 3.1 General overview Figure 3-1 PI P set P act + - ∆P + consumers 1,2 & 3 Q c - sensor Q P distance n Soll 3.2 Constantly controlling and adapting the pressure in the system Table 3-1 No. Function Comments 1. In order to provide the consumers in the cooling water system with a consistent pressure even under varying loads, a PI controll ...

Entry ID: 23753479, V2.3.S, 02/2014

11 © Siemens AG 2014 All rights reserved 3.3 Addressing the motor via an analog interface of the LOGO! Table 3-2 No. Function Comments 5. The setting value (0 to 10V) for the motor speed n setpoint is continuously transmitted by the LOGO! expansion module AM2 AQ to SINAMICS V20 and scaled into a frequency setpoint (0 to 50Hz) there. The lower and upper limit of the frequency setpoint depen ...

Entry ID: 23753479, V2.3.S, 02/2014

12 © Siemens AG 2014 All rights reserved 3.4 Monitor storage tanks and react to a dry run Table 3-3 No. Function Comments 1. To avoid the pump running dry in this cooling water system, a three-pole wire electrode is used for monitoring the water level in the storage tank. 2. For an electrode, the reference point (M), the minimum fill level (Min) and the maximum fill level (Max) are set. 3. ...

Entry ID: 23753479, V2.3.S, 02/2014

13 © Siemens AG 2014 All rights reserved 3.5 Simulation of the controlled system Table 3-4 No. Function Comments 1. With the S7-1200 PLC, the controlled system of this cooling water application can be simulated. This allows the application to be tested under almost real conditions without a complex set-up. 2. The S7-1200 PLC continuously calculates the pressure P actual and transmits it to ...

Entry ID: 23753479, V2.3.S, 02/2014

14 © Siemens AG 2014 All rights reserved 4 Installation This chapter shows the necessary steps to put the example into operation with the code from the download and the hardware list. Note The installation guidelines for LOGO!, SINAMICS V20 and S7-1200 always have to be observed. ! Warning Before installing the SINAMICS V20 and putting it into operation, please read all the safety inst ...

Entry ID: 23753479, V2.3.S, 02/2014

15 © Siemens AG 2014 All rights reserved The SIRIUS monitoring relay (4) is connected to a digital input of the LOGO! logic module. A three-pole wire electrode (8) is connected to the SIRIUS monitoring relay. In this set-up plan, the pressure measuring transducer (The SITRANS P pressure measuring transducer must be removes!) is replaced by a S7-1200, DC/DC/DC (1), which simulates the co ...

Entry ID: 23753479, V2.3.S, 02/2014

16 © Siemens AG 2014 All rights reserved 4.2 Software installation (download) This chapter describes the steps for the installation of the example code. Note The software examples are available on the HTML page from which you downloaded this document. The software examples are always assigned to the components used in the set and show their basic interaction. However, they are no real a ...

Entry ID: 23753479, V2.3.S, 02/2014

17 © Siemens AG 2014 All rights reserved No. Action Comments 7. Set the IP address at the LOGO!: See also LOGO! Manual \3\ 8. Navigate, if necessary with the LOGO! button  to the menu item “Date/Time” 9. Use the button sequence ESC and  to navigate to “Stop”. 10. Stop the program editing with the button sequence OK ,  and OK. 11. Navigate to “Network” with ...

Entry ID: 23753479, V2.3.S, 02/2014

18 © Siemens AG 2014 All rights reserved No. Action Comments 17. Set the operating mode of the LOGO! logic module to “RUN” by means of the symbol “Change LOGO! operating mode”. Installation of the STEP 7 program Table 4-4 No. Action Comments 1. Make sure all the components of STEP 7 and WinCC have been installed. See also Table 2-6: 2. Start STEP 7 (TIA Portal). 3. In STEP 7 (T ...

Entry ID: 23753479, V2.3.S, 02/2014

19 © Siemens AG 2014 All rights reserved No. Action Comments 6. Load the HW configuration and the program into the S7-1200 by means of the function “Extended download to device”. With a right-click on the station, you will reach the menu “Download to device > Hardware and software”. The window for the “Extended download” pops up. Set the type of the PG/PC interface to “PN/ ...

5 Configuration and Settings

Set23_RegSim Entry ID: 23753479, V2.3.S, 02/2014 20 © Siemens AG 2014 All rights reserved 5 Configuration and Settings 5.1 Scaling analog values into physical values in the LOGO! Table 5-1 No. Function Comments 1. Coming and going analog values can be optionally scaled by means of the analog blocks so that the user can have real physical values (such as pressure, temperature, revs/min) displayed in the LOGO!. 2. Set the ...

Related Devices for Siemens LOGO! 0BA7:

550-506
Siemens 550-506 Installation instructions manual
19.08.2026 9 pages

Installation Instructions Document No. 550-308 Rev. 1, July, 2001 CE Compliant Dual Duct Controller — Two Air Velocity Sensors — Electronic Output Page 1 of Instruction guidebook for the Siemens 550-506 Controller. It offers guidance on operating conditions, setup tips, maintenance, product handling.

3VA1 Series
Siemens 3VA1 Series Operating instructions manual
22.04.2026 10 pages

s DE GEFAHR Gefährliche Spannung. Lebensgefahr oder schwere Verletzungsgefahr. Vor Beginn der Arbeiten Anlage und Gerät spannungsfrei schalten. EN DANGER Haza Professional operation guide for the Siemens 3VA1 Series Industrial Electrical. The manual outlines system configuration and operational procedures, installation, setup guidelines, technical guidelines.

WM4HXEE0DN
Siemens WM4HXEE0DN User manual and installation instructions
31.07.2026 84 pages

Washing machine WM4HXEE0DN en User manual and installation instructions Register your product on My Siemens and discover exclusive services and offers. siemens- Full user manual for the Siemens WM4HXEE0DN Washer. This guide explains technical procedures for maintenance, testing procedures, cleaning instructions.

SIRIUS 3RT1916-4BB31
Siemens SIRIUS 3RT1916-4BB31 Original operating instructions
10.08.2026 2 pages

A8E56201905000A/RS-AB/005 Last update: 13 January 2015 3ZX1012-0RT20-4BA1 s SIEMENS AG Telephone: +49 (911) 895-5900 (8°° - 17°° CET) www.siemens.com/sirius Comprehensive instruction manual for the Siemens SIRIUS 3RT1916-4BB31 Cables and connectors. It offers guidance on maintenance, troubleshooting, energy usage.

Multi Address Appearance (MAA) On OpenStage
Siemens Multi Address Appearance (MAA) On OpenStage Technical paper
10.05.2026 23 pages

Technical Paper Siemens Enterprise Communications www.siemens-enterprise.com Issue 1.0 Siemens Enterprise Communications GmbH & Co KG Munich, 07/26/2010 Germany Product manual for the Siemens Multi Address Appearance (MAA) On OpenStage Printer Accessories. This documentation details procedures for daily usage, device features, replacement parts.

Microwave
Siemens Microwave Instruction manual
07.08.2026 160 pages

*4270 ,884270 *< 6>,1 />7 *< .*=270 &:3/A3 @3/2 B67A 7 User guide for the Siemens Microwave Microwave Oven. The document offers guidance on setup validation, menu navigation, component replacement, operating conditions.

PowerLink 100
Siemens PowerLink 100 Product information
09.04.2026 54 pages

Smart Communications PowerLink 100 and PowerLink 50 P3.5 Product Information E50405-U53-X-B3-7670 Preface Open Source Software Table of Contents Safety Instruct Device instruction guide for the Siemens PowerLink 100 Portable Generator. This guide presents instructions on setup validation, product safety, operational guidelines.

3VT3 Series
Siemens 3VT3 Series Operating instructions
15.08.2026 4 pages

Überstromauslöser 3VT3 Overcurrent release 3VT3 Déclencheur à maximum de courant 3VT3 Disparador de sobreintensidad 3VT3 Sganciatore di sovracorrente 3VT3 D User guide for the Siemens 3VT3 Series Circuit breakers. This documentation details procedures for device instructions, network setup, safety precautions, usage recommendations.

Controller: Frequently Requested PDF Instructions

ODISEA
SYCLOPE ODISEA Programming instructions manual
03.09.2026 33 pages

Programming instructions Reference : ODI0001 and ODI0002 Rev : 2 SYCLOPE ODISEA® Controller for public swimming pools (Part 2) Operating handbook for the SYCLOPE ODISEA Controller. It details troubleshooting tips and user instructions, power requirements, interface navigation.

F Series
Fluidwell F Series Manual 
30.07.2026 36 pages

F073-T LEVEL MONITOR WITH HIGH / LOW LEVEL ALARMS Signal input sensor: resistance array Alarm output: one level alarm Options: Intrinsically Safe F-Series - Fie Device instruction guide for the Fluidwell F Series Measuring Instruments. The manual contains instructions for maintenance, repair references, device operation tips.

7000 Series
Eurotherm 7000 Series Operation & user’s manual
10.04.2026 46 pages

Three phase solid state contactor User Manual εε 7300 7300S ENG • DATA MANAGEMENT • CONTROLS • PROCESS AUTOMATION• Step-by-step guide for the Eurotherm 7000 Series Controller. This guide includes system checks, technical overview, warranty information.

MING MECCA
Special Stage Systems MING MECCA Operation & user’s manual
17.06.2026 154 pages

i Comprehensive operating guide for the Special Stage Systems MING MECCA Game Console. This documentation explains configuration and diagnostic information, wiring setup, user settings.