SICK Mounting kit 2 Mounting Instructions
Text of SICK Mounting kit 2 Mounting Instructions
Mounting kit 2
2
• SICK AG • Industrial Safety Systems • Deutschland • Al rights reserved
8 011 148/14-04-05
This document is protected by copyright. The SICK AG company retains this right. Reproducing this document in
whole or part is only permissible within the limits of the statutory regulations of copyright law. Modifying or
abridging the document is impermissible without the express written permission of from the SICK AG
Mounting kit 2 8 011 148/14-04-05
• SICK AG • Industrial Safety Systems • Deutschland • All rights reserved
3
Contents
Contents
1
Product description.....................................................................................................................4
1.1
Scope of delivery............................................................................................................................4
2
Mounting....
Mounting kit 2 4
• SICK AG • Industrial Safety Systems • Deutschland • Al rights reserved
8 011 148/14-04-05
Product description
1
Product description
The retaining device for the V 4000 Press Brake sensor (SICK mounting kit 2) consists of
a vertical adjusting arm, an adapter plate with groove for accommodating the sliding nut
(SICK mounting kit 1) and a horizontal adjusting arm that is mounted to the press
crosshea
Mounting kit 2 8 011 148/14-04-05
• SICK AG • Industrial Safety Systems • Deutschland • All rights reserved
5
Mounting
2
Mounting
2.1
Required tools and aids
� Electric drill and drill bit (metal 6.3 mm)
� Open-end wrenches (sizes 14 and 19)
� Hexagon socket screw keys (sizes 4, 6, 10)
� Side cutting pliers
� Thread cutter (M12 or M8 for mounting without horizontal adjusting arm)
2.2
Mounting alternatives
Mounting kit 2 6
• SICK AG • Industrial Safety Systems • Deutschland • Al rights reserved
8 011 148/14-04-05
Mounting
Mounting on the side of the press crosshead
If the press crosshead has sufficient depth, mounting on the side of the press crosshead
with one adjusting arm each is possible. This alternative requires little clearance in the
width.
Fig. 2: Mounting on the side
of the press crosshead
Mounting kit 2 8 011 148/14-04-05
• SICK AG • Industrial Safety Systems • Deutschland • All rights reserved
7
Mounting
2.3
Mounting on the rear of the press crosshead
2.3.1
Premounting vertical adjusting arms on the left/right
The SICK mounting kit 2 is supplied in two packages. One package contains all the
components required to mount the retaining device onto one side of the press crosshead.
The vertical adjusting
Mounting kit 2 8
• SICK AG • Industrial Safety Systems • Deutschland • Al rights reserved
8 011 148/14-04-05
Mounting
2.3.2
Premounting horizontal adjusting arms on the left/right
� Remove the screws (6).
� Place the cross adapter (4) on the adjusting arm (1) so that the hole for the clamping
lever (5) shows to the left at the left-hand adjusting arm and to the right at the right-hand
adjusting arm.
� Mount th
Mounting kit 2 8 011 148/14-04-05
• SICK AG • Industrial Safety Systems • Deutschland • All rights reserved
9
Mounting
Mounting horizontal adjusting arms on the press crosshead on the left/right
� Slide the shim (1) sideways into the groove.
� Push the screws M12 x 60 (3) with washers for M12 (2) through the shim into the holes.
� Mount the adjusting arms from the rear to the press crosshead.
� Tighten the s
Mounting kit 2 10
• SICK AG • Industrial Safety Systems • Deutschland • Al rights reserved
8 011 148/14-04-05
Mounting
� Tighten the clamping lever.
� Screw the screw for the upper back-stop M8 x 15 (6) into the vertical adjusting arm.
Mounting the vertical adjusting arm on the right
� Carry out mounting as for the left.
2.3.5
Applying latching marks
.
Latching marks can be applied at the vertical adjusting ar
Mounting kit 2 8 011 148/14-04-05
• SICK AG • Industrial Safety Systems • Deutschland • All rights reserved
11
Mounting
2.3.6
Mounting cables
� Slide the cable tie clips (2) sideways into the groove of the horizontal adjusting arm (1).
� Use the open-end wrench (size 19) to turn the cable tie clips clockwise by 90 .
� Remove 3 screws each on the left- and right-hand sides of the adapter plate (3). Loosen
the 4
Mounting kit 2 12
• SICK AG • Industrial Safety Systems • Deutschland • Al rights reserved
8 011 148/14-04-05
Mounting
� Push the remaining cable protection tube from above over the cables until the cable
protection tube projects 7 cm into the adjusting arm.
� Repeat the procedure on the sender end. Insert the cables and attach the cable
protection.
� Bend the cable protection tube (2) at both adjusting arms a
Mounting kit 2 8 011 148/14-04-05
• SICK AG • Industrial Safety Systems • Deutschland • All rights reserved
13
Mounting
� Fasten the cable protection tube (2) on the top using the cable ties (4). Ensure that the
cable tie is positioned in a slot of the cable protection tube.
� Insert the cable ties through the cable fastening clips (3) and fasten the cable protection
tube. Ensure that the cable has sufficient mo
A u s t r a l i a
Phone
+61 3 9497 4100
1800 33 48 02 – tollfree
E-Mail
[email protected]
B e l g i u m / L u x e m b o u r g
Phone
+32 (0)2 466 55 66
E-Mail
[email protected]
B r a s i l
Phone
+55 11 5091-4900
E-Mail
[email protected]
C e s k á R e p u b l i k a
Phone
+420 2 57 91 18 50
E-Mail
[email protected]
C h i n a
Phone
+852-2763 6966
E-Mail
[email protected]
D a n m a r k
Phone
+45 45 82 64 00
E-Mail
[email protected]
D e u t s c h l a n d
Phone
+49 (0)