SICK WLD26 Operating Instructions Manual

Text of SICK WLD26 Operating Instructions Manual

This work is protected by copyright. Any rights derived from the copyright shall be

reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐ tion, abridgment or translation of this document is prohibited without the express writ‐ ten

General safety notes................................................................................

4 1.2 Notes on UL approval............................................................................... 4 2 Intended use...................................................................................... 4 3 Operating and status indicators...

General safety notes

■ Read the operating instructions before commissioning. ■ Connection, mounting, and configuration may only be performed by trained specialists. ■ 2006/42/EC NO SAFETY Not a safety component in accordance with the EU Machinery Directive. ■ When commissioning, protect the device from moisture and contamination. ■ These operating instructions contain information required during the life cycle of the sen

The sensors must be connected in a voltage-free state (UV = 0 V). The following informa‐

tion must be observed, depending on the connection type: – Male connector connection: Note pin assignment – Cable: wire color Only apply voltage/switch on the voltage supply (UV > 0 V) once all electrical connec‐ tions have been established. Explanations on connection diagram (table 1 - table 5) Alarm = alarm output (table 4) Health =

SICK WLD26 Table 3: Push / pull

Q Push-pull (≤ 100 mA) + (L+) Q ‒ (M) + (L+) Q ‒ (M) Q Push-pull (≤ 100 mA) + (L+) Q ‒ (M) + (L+) Q ‒ (M) 6 Additional functions Alarm Alarm output: The sensor (WLD26) features a pre-failure notification output (“Alarm” in connection diagram [table 4]), which issues a notification if the sensor is only ready for operation to a limited extent. The LED indicator flashes in this case. Possible causes: Sensor or reflector i

Table 4: Alarm / Health

Alarm (≤ 100 mA) Health (≤100 mA) + (L+) Alarm ‒ (M) + (L+) Health ‒ (M) + (L+) Alarm ‒ (M) + (L+) Health ‒ (M) Test input Test input: The WLD26 sensors feature a test input (“TI” or “Test” on the connection diagram [see table 2 and table 5]), which can be used to switch the sender off and, therefore, check that the sensor is functioning correctly: If female cable connectors with LED indicators are used, you have

Figure 1: Alignment

2 Sensing range Adjust the distance between the sensor and the reflector according to the corresponding diagram [see figure 2] (x = sensing range, y = operating reserve). 0 100 10 1 7 6 1 3 4 2 5 WLD26P-xxxxx1xx 4 (13.12) 8 (26.25) 12 (39.37) 16 (52.49) 20 (65.62) Operating reserve Distance in m (feet) Sensing range Figure 2: Characteristic line 1 1 Reflector PL22 2 Reflector P250 3 Reflector PL20A 4 Reflector PL30A 5 Reflector PL40A 6

Distance in m (feet)

3 4 1 2 Sensing range WLD26P-xxxxx1xx Figure 4: Characteristic line 2 1 Reflector PL20 CHEM 2 Reflector P250 CHEM 3 Reflector P250H 4 Reflector PL40 Antifog 0 Sensing range Distance in m (feet) 0.25 7 10 0.25 10 14 0.25 4 6 � � � � Sensing range max. 4 (13.12) 8 (26.25) 12 (39.37) 16 (52.49) 20 (65.62) 0.25 10 12 Figure 5: Bar graph 2 0 2 (6.56) 6

Disassembly and disposal

The sensor must be disposed of according to the applicable country-specific regula‐ tions. Efforts should be made during the disposal process to recycle the constituent materials (particularly precious metals). NOTE Disposal of batteries, electric and electronic devices • According to international directives, batteries, accumulators and electrical or electronic devices must not be disposed of in general waste. • The owner

Ambient operating temperature

–40 °C ... +60 °C8) 1) 16 VDC to 30 VDC, without load 2) 10 VDC to 16 VDC, without load 3) Signal transit time with resistive load 4) With a light/dark ratio of 1:1. 5) Pursuant to EN 60529 6) Replaces IP69 K pursuant to ISO 20653: 2013-03 7) A = UB-connections reverse polarity protected B = inputs and output reverse-polarity protected C = Interference suppression D = outputs overcurrent and short-circuit protected

Dieses Werk ist urheberrechtlich geschützt. Die dadurch begründeten Rechte bleiben

bei der Firma SICK AG. Die Vervielfältigung des Werks oder von Teilen dieses Werks ist nur in den Grenzen der gesetzlichen Bestimmungen des Urheberrechtsgesetzes zuläs‐ sig. Jede Änderung, Kürzung oder Übersetzung des Werks ohne ausdrückliche schriftli�

SICK WLD26 Zu Ihrer Sicherheit............................................................................. 15

12.1 Allgemeine Sicherheitshinweise.............................................................. 15 12.2 Hinweise zur UL Zulassung...................................................................... 15 13 Bestimmungsgemäße Verwendung............................................... 15 14 Bedien- und Anzeigeelemente...............................

SICK WLD26 Zu Ihrer Sicherheit

12.1 Allgemeine Sicherheitshinweise ■ Lesen Sie vor der Inbetriebnahme des Geräts die Betriebsanleitung. ■ Der Anschluss, die Montage und die Konfiguration des Geräts dürfen nur von geschultem Fachpersonal vorgenommen werden. ■ 2006/42/EC NO SAFETY Bei diesem Gerät handelt es sich um kein sicherheitsgerichtetes Bauteil im Sinne der EU-Maschinenrichtlinie. ■ Bei der Inbetriebnahme ist das Gerät ausreichend vor Feuchtigke

Maximal zulässiges Anzugsdrehmoment des Sensors von < 1,3 Nm beachten.

16 Elektrische Installation Anschluss der Sensoren muss spannungsfrei (UV = 0 V) erfolgen. Je nach Anschlussart sind die folgenden Informationen zu beachten: – Steckeranschluss: Pinbelegung beachten – Leitung: Adernfarbe Erst nach Anschluss aller elektrischen Verbindungen die Spannungsversorgung (UV > 0 V) anlegen bzw. einschalten. Erläuterungen zum Anschlussschema (Tabelle 6 - Ta

Tabelle 8: Push / Pull

Q push-pull (≤ 100 mA) + (L+) Q ‒ (M) + (L+) Q ‒ (M) Q push-pull (≤ 100 mA) + (L+) Q ‒ (M) + (L+) Q ‒ (M) 17 Zusatzfunktionen Alarm Alarmausgang: Der Sensor (WLD26) verfügt über einen Vorausfallmeldeausgang ("Alarm" im Anschlussschema [siehe Tabelle 4]), der meldet, wenn der Sensor nur noch eingeschränkt betriebsbereit ist. Dabei blinkt die Anzeige-LED. Mögliche Ursachen: Ver‐ schmutzung von Sensor oder Reflektor, S

Tabelle 9: Alarm / Health

Alarm (≤ 100 mA) Health (≤100 mA) + (L+) Alarm ‒ (M) + (L+) Health ‒ (M) + (L+) Alarm ‒ (M) + (L+) Health ‒ (M) Testeingang Testeingang: Die Sensoren WLD26 verfügen über einen Testeingang („TE“ oder „Test“ im Anschlussschema [siehe Tabelle 2 und Tabelle 5]), mit dem der Sender ausgeschal‐ tet und somit die ordnungsgemäße Funktion des Sensors überprüft werden kann: Bei Verwendung von Leitungsdosen mit LE

Abbildung 10: Ausrichtung

2 Schaltabstand Distanz zwischen Sensor und Reflektor mit dem zugehörigen Diagramm [siehe Abbildung 11] abgleichen (x = Schaltabstand, y = Funktionsreserve). 0 4 8 12 16 20 100 10 1 Funktionsreserve Abstand in m 7 6 1 3 4 2 5 Betriebs- reichweite WLD26P-xxxxx1xx Abbildung 11: Kennlinie 1 1 Reflektor PL22 2 Reflektor P250 3 Reflektor PL20A 4 Reflektor PL30A 5 Reflektor PL40A 6 Reflektor C110 7 Reflektor PL80A 0 Schaltabstand Absta