ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING WARNING: Installer’s Guide ▲ WARNING ! SAFETY HAZARD! THIS INFORMATION ...

12. If field installed electric heaters are applied, minimum

airflow settings, unit and duct clearances to combus- tibles must be maintained as stated on the Air Handler rating nameplate. 13. If the unit is installed without a return air duct, appli- cable local codes may limit this Air Handler to installa- tion only in a si ...

16. If side, front or rear return is required, Air Handler must

be elevated or placed on a plenum [TAYPLNM100 for 4TEE3D02, 03, 04, 06, & 08 (23.5" wide), TAYPLNM101 for 4TEE3D01 (21.5" wide), TAYPLNM102 for 4TEE3D05, 07, 09, & 10 (26" wide)]. Connecting return duct directly to the side, front or rear of the cabinet is not a ...

Figure 6. FIELD CHARGER Retainer Bracket Removal

B. TWO PIECE CABINET DISASSEMBLY (OPTIONAL) NOTE: For easier installation into tight areas, the 4TEE3D03, 04, 06, 08, 09, & 4TEE3D10B air handlers can be disassembled, moved to an attic or other space, and then reassembled. Steps for disassembly and reassembly (See Figures 3 a ...

Figure 7. FIELD CHARGER Removal

Figure 8. Protector Plate Removal 4. The horizontal drip tray should be removed for maximum efficiency. See Figures 9, 10, and 11. a. Remove the coil by sliding it out on the coil channel supports. For the 4TEE3D05, 07, 09, & 10 units, there is a coil support tab at the top of the coil, connec ...

Sheetmetal screws CANNOT be used to attach

the return ductwork on the side of the unit. 10. Pedestal and unit should be isolated from the foun- dation using a suitable isolating material. 11. Openings where field wiring enters the cabi- net must be completely sealed. Location of power entry is shown on the outline drawing ...

on Bottom side

Electrical Contacts on Bottom side Electrical Contacts on Bottom side FIELD CHARGER COLLECTION CELL DOWNFLOW Actuator Tab Electrical Contacts Electrical Contacts FIELD CHARGER COLLECTION CELL Downflow and Horizontal Left orientations available with application of Downflow kit provi ...

Figure 16. Mounting Installation Options

for Horizontal Applications HORIZONTAL RIGHT 1. Unit is shipped from the factory in the horizontal right configuration. Unit conversion is not re- quired. 2. If the unit is suspended, it must be supported from the bottom near both ends as well as the middle to prevent sagging. Th ...

F. BRAZING TO EVAPORATOR SECTION

NOTE: A brazing shield is provided in the Accessory Kit accompanying this unit. This shield fits over the re- frigerant fittings while brazing. Wet the shield before brazing. See Figure 19. IMPORTANT: Do NOT unseal refrigerant tubing until ready to cut and fit refrigerant lines. 1. Remove b ...