CHAPTER 1. BEFORE SERVICING
CHAPTER 2. WARNING TO SERVICE PERSONNEL
CHAPTER 3. PRODUCT SPECIFICATIONS
CHAPTER 4. APPEARANCE VIEW
CHAPTER 5. OPERATION SEQUENCE
CHAPTER 6. FUNCTION OF IMPORTANT COMPO-
NENTS
CHAPTER 7. TROUBLESHOOTING GUIDE
CHAPTER 8. TEST PROCEDURES
CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY
CHAPTER 10. PRECAUTIONS FOR USING LEAD-
FREE SOLDER
CHAPTER 11. COMPONENT REPLACEMENT AND
ADJUSTMENT PROCEDURE
CHAPTER 12. MICROWAVE MEASUREMENT
CHAPTER 13
CHAPTER 1. BEFORE SERVICING [1]
GENERAL IMPORTANT INFORMATION.....1-1
[2]
WARNING ..................................................1-1
[3]
CAUTION MICROWAVE RADIATION........1-2
CHAPTER 2. WARNING TO SERVICE PERSONNEL
CHAPTER 3. PRODUCT SPECIFICATIONS
CHAPTER 4. APPEARANCE VIEW
[1]
OVEN .........................................................4-1
[2]
TOUCH CONTROL PANEL........................4-1
CHAPTER 5. OPERATION SEQUENCE
[1]
OFF CONDITION ..
1 – 1
R239(W)
Service Manual
CHAPTER 1. BEFORE SERVICING
[1] GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information.
It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer ser-
vice.
[2] WARNING
Never operate the oven until the following points are ensured.
(A) The door i
1 – 2
[3] CAUTION MICROWAVE RADIATION
Personnel should not be exposed to the microwave energy which may radiate from the
magnetron or other microwave generating devices if it is improperly used or connected.
All input and output microwave connections, waveguides, flanges and gaskets must be
secured.
Never operate the device without a microwave energy absorbing load attached.
Never look into an open waveguide or antenna while the device is energiz
2 – 1
R239(W)
Service Manual
CHAPTER 2. WARNING TO SERVICE PERSONNEL
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge high voltage capacitor.
WARNING: AGAINST THE CHARGE OF THE
HIGH-VOLTAGE CAPACITOR
GB
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following
parts will result in electrocution.
High voltage capacitor, High voltage transformer, Magnetr
3 – 1
R239(W)
Service Manual
CHAPTER 3. PRODUCT SPECIFICATIONS
TEM
DESCRIPTION
Power Requirements
230 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.25 kW
Power Output
800 watts nominal of RF microwave energy (IEC60705 Test Procedure)
Operating frequency 2450 MHz
Case Dimensions
Width 460 mm
Height 275 mm including foot
Depth 380 mm
Cooking Cavity Dimensions
Width 319 mm NOTE: Internal capacity is calculated by measuring
4 – 1
R239(W)
Service Manual
CHAPTER 4. APPEARANCE VIEW
[1] OVEN
1. Ventilation openings
2. Oven lamp
3. Door hinges
4. Door safety latches
5. See through door
6. Door seals sealing surfaces
7. Coupling
8. Control panel
9. Waveguide cover
10. Power supply cord
11. Turntable
12. Roller stay
13. Outer case cabinet
14. Door opening handle
[2] TOUCH CONTROL PANEL
1. Digital Display
2. Indicators
The appropriate indicator will flash or light up, just
5 – 1
R239(W)
Service Manual
CHAPTER 5. OPERATION SEQUENCE
[1] OFF CONDITION
Closing the door activates all door interlock switches (1st. latch switch,
2nd. interlock relay control switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts (COM-NC)
must be open.
When the microwave oven is plugged in a wall outlet, rated voltage is
supplied to the noise filter and the control unit.
Fig
6 – 1
R239(W)
Service Manual
CHAPTER 6. FUNCTION OF IMPORTANT COMPONENTS
[1] DOOR OPEN MECHANISM
The door is opened by pulling the door, refer to the Figure D-1.
Figure D-1. Door Open Mechanism
[2] 1ST. LATCH SWITCH (SW1) AND 2ND.
INTERLOCK RELAY CONTROL SWITCH
(SW3)
1. When the oven door is closed, the contacts (COM-NO) must be
closed.
2. When the oven door is opened, the contacts (COM-NO) must be
opened.
[3] MONITOR
7 – 1
R239(W)
Service Manual
CHAPTER 7. TROUBLESHOOTING GUIDE
[1] FOREWORD
When troubleshooting the microwave oven, it is helpful to follow the
Sequence of Operation in performing the checks. Many of the possible
causes of trouble will require that a specific test be performed. These
tests are given a procedure letter which will be found in the "Test Pro-
cedure"section.
IMPORTANT:
If the oven becomes inoperative because of a blown fuse F1 T6.3A
Sharp R-239 8 – 1
R239(W)
Service Manual
CHAPTER 8. TEST PROCEDURES
[1] Procedure A : MAGNETRON (MG) TEST
NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL WHILE THE OVEN IS IN OPERATION.
CARRY OUT 3D CHECKS.
Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament termin
8 – 2
[2] Procedure B: HIGH VOLTAGE TRANSFORMER (T) TEST
1. CARRY OUT 3D CHECKS.
2. Disconnect the leads to the primary winding of the high voltage transformer. Disconnect the filament and secondary winding connections from the
rest of the HV circuitry. Using an ohmmeter, set on a low range, it is possible to check the continuity of all three winding. The following readings
should be obtained:
a.Primary winding -----------------
8 – 3
[5] Procedure E: SWITCH (SW, SW2, SW3) TEST
CARRY OUT 3D CHECKS.
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table.
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT 4R CHECKS.
[6] Procedure F: TEMPERATURE FUSE (TF) TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the temperature fuse. Then using an
Sharp R-239 8 – 4
[10] Procedure J: HIGH VOLTAGE FUSE (F2) TEST
CARRY OUT 3D CHECKS.
If the high voltage fuse F2 is blown, there could be a short in the high voltage rectifier or the magnetron MG.
Check them and replace the defective parts and the high voltage fuse F2.
CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE HIGH VOLTAGE FUSE F2 WITH THE CORRECT VALUE REPLACEMENT.
[11] Procedure K: TOUCH CONTROL PANEL ASSEMBLY TEST
The touch control panel consists of circ
8 – 5
[13] Procedure M: RELAY (RY1, RY2) TEST
CARRY OUT 3D CHECKS.
Remove the outer case and check voltage between the normal open terminal of the relay RY1 and the normal open terminal of the relay RY2 on the
control unit with an A.C. voltmeter. The meter should indicate 230 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave
9 – 1
R239(W)
Service Manual
CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY
[1] OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units as shown in
the touch control panel circuit.
(1) Switch Unit (2) Control Unit
The principal functions of these units and their related signals are
explained below.
1. Switch Unit
The switch unit is composed of a matrix, signals generated in the LSI
are sent to the switch unit throu
9 – 2
25
COM3
OUT
Terminal not used.
26-37
SEG0-SEG11
OUT
Segment data signal.
Connected to LCD.The relation between signals are as follows:
LSI signal (Pin No.) LCD (segment) LSI signal (Pin No.) LCD (segment)
SEG 0 (26) ----------------- S 1 SEG 6 (32) ----------------- S 7
SEG 1 (27) ----------------- S 2 SEG 7 (33) ----------------- S 8
SEG 2 (28) -------
9 – 3
[3] SERVICING FOR TOUCH CONTROL PANEL
1. Precautions for Handling Electronic Components
This unit uses CMOS LSI in the integral part of the circuits. When han-
dling these parts, the following precautions should be strictly followed.
CMOS LSI have extremely high impedance at its input and output ter-
minals. For this reason, it is easily influenced by the surrounding high
voltage power source, static electricity charge in clothes, etc., and