Sharp R-239 Service Manual

Text of Sharp R-239 Service Manual

CHAPTER 1. BEFORE SERVICING

CHAPTER 2. WARNING TO SERVICE PERSONNEL CHAPTER 3. PRODUCT SPECIFICATIONS CHAPTER 4. APPEARANCE VIEW CHAPTER 5. OPERATION SEQUENCE CHAPTER 6. FUNCTION OF IMPORTANT COMPO- NENTS CHAPTER 7. TROUBLESHOOTING GUIDE CHAPTER 8. TEST PROCEDURES CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY CHAPTER 10. PRECAUTIONS FOR USING LEAD- FREE SOLDER CHAPTER 11. COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE CHAPTER 12. MICROWAVE MEASUREMENT CHAPTER 13
CHAPTER 1. BEFORE SERVICING [1] GENERAL IMPORTANT INFORMATION.....1-1 [2] WARNING ..................................................1-1 [3] CAUTION MICROWAVE RADIATION........1-2 CHAPTER 2. WARNING TO SERVICE PERSONNEL CHAPTER 3. PRODUCT SPECIFICATIONS CHAPTER 4. APPEARANCE VIEW [1] OVEN .........................................................4-1 [2] TOUCH CONTROL PANEL........................4-1 CHAPTER 5. OPERATION SEQUENCE [1] OFF CONDITION ..

1 – 1

R239(W) Service Manual CHAPTER 1. BEFORE SERVICING [1] GENERAL IMPORTANT INFORMATION This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer ser- vice. [2] WARNING Never operate the oven until the following points are ensured. (A) The door i

1 – 2

[3] CAUTION MICROWAVE RADIATION Personnel should not be exposed to the microwave energy which may radiate from the magnetron or other microwave generating devices if it is improperly used or connected. All input and output microwave connections, waveguides, flanges and gaskets must be secured. Never operate the device without a microwave energy absorbing load attached. Never look into an open waveguide or antenna while the device is energiz

2 – 1

R239(W) Service Manual CHAPTER 2. WARNING TO SERVICE PERSONNEL REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3) Discharge high voltage capacitor. WARNING: AGAINST THE CHARGE OF THE HIGH-VOLTAGE CAPACITOR GB Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts will result in electrocution. High voltage capacitor, High voltage transformer, Magnetr

3 – 1

R239(W) Service Manual CHAPTER 3. PRODUCT SPECIFICATIONS TEM DESCRIPTION Power Requirements 230 Volts 50 Hertz Single phase, 3 wire earthed Power Consumption 1.25 kW Power Output 800 watts nominal of RF microwave energy (IEC60705 Test Procedure) Operating frequency 2450 MHz Case Dimensions Width 460 mm Height 275 mm including foot Depth 380 mm Cooking Cavity Dimensions Width 319 mm NOTE: Internal capacity is calculated by measuring

4 – 1

R239(W) Service Manual CHAPTER 4. APPEARANCE VIEW [1] OVEN 1. Ventilation openings 2. Oven lamp 3. Door hinges 4. Door safety latches 5. See through door 6. Door seals sealing surfaces 7. Coupling 8. Control panel 9. Waveguide cover 10. Power supply cord 11. Turntable 12. Roller stay 13. Outer case cabinet 14. Door opening handle [2] TOUCH CONTROL PANEL 1. Digital Display 2. Indicators The appropriate indicator will flash or light up, just

5 – 1

R239(W) Service Manual CHAPTER 5. OPERATION SEQUENCE [1] OFF CONDITION Closing the door activates all door interlock switches (1st. latch switch, 2nd. interlock relay control switch). IMPORTANT When the oven door is closed, the monitor switch contacts (COM-NC) must be open. When the microwave oven is plugged in a wall outlet, rated voltage is supplied to the noise filter and the control unit. Fig

6 – 1

R239(W) Service Manual CHAPTER 6. FUNCTION OF IMPORTANT COMPONENTS [1] DOOR OPEN MECHANISM The door is opened by pulling the door, refer to the Figure D-1. Figure D-1. Door Open Mechanism [2] 1ST. LATCH SWITCH (SW1) AND 2ND. INTERLOCK RELAY CONTROL SWITCH (SW3) 1. When the oven door is closed, the contacts (COM-NO) must be closed. 2. When the oven door is opened, the contacts (COM-NO) must be opened. [3] MONITOR

7 – 1

R239(W) Service Manual CHAPTER 7. TROUBLESHOOTING GUIDE [1] FOREWORD When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Pro- cedure"section. IMPORTANT: If the oven becomes inoperative because of a blown fuse F1 T6.3A

Sharp R-239 8 – 1

R239(W) Service Manual CHAPTER 8. TEST PROCEDURES [1] Procedure A : MAGNETRON (MG) TEST NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL WHILE THE OVEN IS IN OPERATION. CARRY OUT 3D CHECKS. Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament termin

8 – 2

[2] Procedure B: HIGH VOLTAGE TRANSFORMER (T) TEST 1. CARRY OUT 3D CHECKS. 2. Disconnect the leads to the primary winding of the high voltage transformer. Disconnect the filament and secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low range, it is possible to check the continuity of all three winding. The following readings should be obtained: a.Primary winding -----------------

8 – 3

[5] Procedure E: SWITCH (SW, SW2, SW3) TEST CARRY OUT 3D CHECKS. Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table. If incorrect readings are obtained, make the necessary switch adjustment or replace the switch. CARRY OUT 4R CHECKS. [6] Procedure F: TEMPERATURE FUSE (TF) TEST CARRY OUT 3D CHECKS. Disconnect the leads from the terminals of the temperature fuse. Then using an

Sharp R-239 8 – 4

[10] Procedure J: HIGH VOLTAGE FUSE (F2) TEST CARRY OUT 3D CHECKS. If the high voltage fuse F2 is blown, there could be a short in the high voltage rectifier or the magnetron MG. Check them and replace the defective parts and the high voltage fuse F2. CARRY OUT 4R CHECKS. CAUTION: ONLY REPLACE HIGH VOLTAGE FUSE F2 WITH THE CORRECT VALUE REPLACEMENT. [11] Procedure K: TOUCH CONTROL PANEL ASSEMBLY TEST The touch control panel consists of circ

8 – 5

[13] Procedure M: RELAY (RY1, RY2) TEST CARRY OUT 3D CHECKS. Remove the outer case and check voltage between the normal open terminal of the relay RY1 and the normal open terminal of the relay RY2 on the control unit with an A.C. voltmeter. The meter should indicate 230 volts, if not check oven circuit. RY1 and RY2 Relay Test These relays are operated by D.C. voltage Check voltage at the relay coil with a D.C. voltmeter during the microwave

9 – 1

R239(W) Service Manual CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY [1] OUTLINE OF TOUCH CONTROL PANEL The touch control section consists of the following units as shown in the touch control panel circuit. (1) Switch Unit (2) Control Unit The principal functions of these units and their related signals are explained below. 1. Switch Unit The switch unit is composed of a matrix, signals generated in the LSI are sent to the switch unit throu

9 – 2

25 COM3 OUT Terminal not used. 26-37 SEG0-SEG11 OUT Segment data signal. Connected to LCD.The relation between signals are as follows: LSI signal (Pin No.) LCD (segment) LSI signal (Pin No.) LCD (segment) SEG 0 (26) ----------------- S 1 SEG 6 (32) ----------------- S 7 SEG 1 (27) ----------------- S 2 SEG 7 (33) ----------------- S 8 SEG 2 (28) -------

9 – 3

[3] SERVICING FOR TOUCH CONTROL PANEL 1. Precautions for Handling Electronic Components This unit uses CMOS LSI in the integral part of the circuits. When han- dling these parts, the following precautions should be strictly followed. CMOS LSI have extremely high impedance at its input and output ter- minals. For this reason, it is easily influenced by the surrounding high voltage power source, static electricity charge in clothes, etc., and