SEW 4338 mO Instruction Manual
| Brand: | SEW |
| Category: | Measuring Instruments |
| Model: | 4338 mO (Instruction Manual) |
| File Type: | |
| File Size: | — |
| Pages: | 16 |
Text of SEW 4338 mO Instruction Manual
SEW 4338 mO 2. SAFETY NOTES.............................
3. FEATURES.....................................
4. SPECIFICATIONS..........................
5. GENERAL.......................................
6. INSTRUMENT LAYOUT..................
7. MEASUREMENT.............................
8. MAINTENANCE..............................
9. FUSE REPLACEMENT...................
PAGE
1
2
3
4
5
6-10
10-12
13
14
This meter has been designed and tested According
to CE Safety Requirements for Electronic Measuring
Apparatus, IEC / EN 61010-1 and other safety
standards. Follow all warnings to ensure safe
operation.
WARNING
READ "SAFETY NOTES" (NEXT PAGE) BEFORE
USING THE METER.
CAT IV - Is for measurements performed at the
source of the low voltage installation.
CAT III - Is for measurements performed in the
building installation.
CAT II
- Is
2. SAFETY NOTES
● Read the following safety information carefully
Before attempting to operate or service the meter.
● Use the meter only as specified in this manual.
Otherwise, the protection provided by the meter
may be impaired.
● Rated environmental conditions :
(1) Indoor Use.
(2) Installation Category IV.
(3) Pollution Degree 2.
(4) Altitude up to 2000 meters.
(5) Relative humidity 80% max.
(6) Ambient temperature 0~40°C.
● Observe t
● Four terminal measurement for mΩ.
● 4-wire method testing(mΩ): 1100.0mΩ / 11000mΩ.
● 2-wire method resistance testing: 110.00Ω /
1.1000kΩ / 11.000kΩ / 110.00kΩ / 1.1000MΩ /
11.000MΩ / 110.0MΩ.(auto ranging)
● Maximum resolution of 0.1mΩ.
● Large LCD (68×34mm).
● Relative mode / Auto-zero mode.
● Data hold function.
● MAX/MIN function.
● Power source: 1.5V "C" battery × 8
● Long battery life and stable pow
mΩ measurement (4-wire method)
Measuring ranges
(mΩ)
0~1100.0mΩ in steps of 100uΩ
0~11000mΩ in steps of 1mΩ
Accuracy
±0.8% of reading ±4 digits over the
operating temperature range
0°C ~ 40°C,
with the supplied test leads
Resistance measurement
Range
Resolution
Accuracy
110.00Ω
0.01Ω
0~2MΩ: ±(1.2%rdg+3dgt)
2~40MΩ: ±(2.0%rdg+4dgt)
40~110MΩ: ±(8.0%rdg+4dgt)
1.1000kΩ
0.1Ω
11.000kΩ
1Ω
110.00kΩ
10Ω
1.1000MΩ
100Ω
1
SEW 4338 mO ● Protection fuse:
200mA/250V × 1
● Dimensions :
250(L) × 190(W) ×126(D)mm
● Weight :
Approx. 1848g (battey included)
● Power source :
1.5V "C" battery × 8
● Low Battery Indication :
" " sign appears on the display when the battery
voltage drops below accurate operating level.
● Accessories :
Instruction Manual
Test leads
Shoulder belt
Batteries
B
SEW 4338 mO 6. INSTRUMENT LAYOUT
(1)
(5)
(3)
(7)
(2)
(6)
(8)
(4)
(9)
(10)
(11)
MAX
MIN
HOLD
REL
TEST
TEST
ON
DIGITAL MILLIOHM METER
AND RESISTANCE TESTER
OFF
1100.0mΩ
11000mΩ
mΩ
(AUTO)
110MΩ
110.00Ω
LOCK
~
● Test Leads
● Special Resistance Test Lead
(Specialized for 2-wire resistance testing)
(1) C1 Termianl
This is the C1 terminal which is used for mΩ
measurement, for 1100.0mΩ and 11000mΩ
(4-wire testing).
(2) P1 Termianl
This is the P1 terminal which is used for mΩ
measurement, for 1100.0mΩ and 11000mΩ
(4-wire testing).
(3) P2 Termianl
This is the P2 terminal which is used for mΩ
measurement, for 1100.0mΩ and 11000mΩ
(4-wire testing).
This terminal is also the COM terminal for
resistance measurement, for 110.00Ω~110M�
SEW 4338 mO (4) C2 Termianl
This is the P2 terminal which is used for mΩ
measurement, for 1100.0mΩ and 11000mΩ
(4-wire testing).
This terminal is also the COM terminal for
resistance measurement, for 110.00Ω~110MΩ
(2-wire testing).
(5) Ω Terminal
This is the positive input termial for resistance
measurement, for 110.00Ω~110MΩ(2-wire
testing).
(6) Function Rotary Switch
The function rotary switch is for selecting different
functions.
(7) TEST Button
(9) REL Button
In REL mode, the LCD displays DN+K-DN, where
DN=1,2,3,..., DN is the last value before REL is
pushed, and DN+K is the current value. If REL is
pushed again in REL mode, the meter displays
the reference value. The meter returns to normal
operation if REL is pressed and held for longer
than one second. Pressing HOLD in REL mode
makes the meter stop updating the reading on the
LCD.
(10) HOLD Button
HOLD mode makes the meter stop updating th
SEW Measuring Instruments Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
ST-2001 |
ST-2001 (Measuring Instruments ePDF User Manual, #1PU1YV) |
13 | 443 | 67 | 13-04-2026 | |
2950 CL |
#R255QO: 2950 CL Measuring Instruments Instruction manual |
13 | 743 | 119 | 21-05-2026 | |
4338 mO |
User Manual: SEW 4338 mO (ZW5SD9, Upd.10-06-2026) |
16 | 992 | 189 | 10-06-2026 | |
6213A-IN |
PDF User Guide (@IK1MU8), SEW 6213A-IN Measuring Instruments (13-07-2026) |
24 | 400 | 80 | 13-07-2026 | |
3800 CL |
User Guide: SEW 3800 CL (J1D6EC, Upd.23-08-2026) |
12 | 677 | 109 | 23-08-2026 | |
PT-30 |
#8OH9VV: PT-30 Measuring Instruments Instruction manual |
12 | 1293 | 220 | 19-04-2026 |