SEW 4338 mO Instruction Manual

Brand: SEW
Category: Measuring Instruments
Model: 4338 mO (Instruction Manual)
File Type: PDF
File Size: —
Pages: 16
Text of SEW 4338 mO Instruction Manual

SEW 4338 mO 2. SAFETY NOTES.............................

3. FEATURES..................................... 4. SPECIFICATIONS.......................... 5. GENERAL....................................... 6. INSTRUMENT LAYOUT.................. 7. MEASUREMENT............................. 8. MAINTENANCE.............................. 9. FUSE REPLACEMENT................... PAGE 1 2 3 4 5 6-10 10-12 13 14

This meter has been designed and tested According

to CE Safety Requirements for Electronic Measuring Apparatus, IEC / EN 61010-1 and other safety standards. Follow all warnings to ensure safe operation. WARNING READ "SAFETY NOTES" (NEXT PAGE) BEFORE USING THE METER. CAT IV - Is for measurements performed at the source of the low voltage installation. CAT III - Is for measurements performed in the building installation. CAT II - Is

2. SAFETY NOTES

● Read the following safety information carefully Before attempting to operate or service the meter. ● Use the meter only as specified in this manual. Otherwise, the protection provided by the meter may be impaired. ● Rated environmental conditions : (1) Indoor Use. (2) Installation Category IV. (3) Pollution Degree 2. (4) Altitude up to 2000 meters. (5) Relative humidity 80% max. (6) Ambient temperature 0~40°C. ● Observe t

● Four terminal measurement for mΩ.

● 4-wire method testing(mΩ): 1100.0mΩ / 11000mΩ. ● 2-wire method resistance testing: 110.00Ω / 1.1000kΩ / 11.000kΩ / 110.00kΩ / 1.1000MΩ / 11.000MΩ / 110.0MΩ.(auto ranging) ● Maximum resolution of 0.1mΩ. ● Large LCD (68×34mm). ● Relative mode / Auto-zero mode. ● Data hold function. ● MAX/MIN function. ● Power source: 1.5V "C" battery × 8 ● Long battery life and stable pow

mΩ measurement (4-wire method)

Measuring ranges (mΩ) 0~1100.0mΩ in steps of 100uΩ 0~11000mΩ in steps of 1mΩ Accuracy ±0.8% of reading ±4 digits over the operating temperature range 0°C ~ 40°C, with the supplied test leads Resistance measurement Range Resolution Accuracy 110.00Ω 0.01Ω 0~2MΩ: ±(1.2%rdg+3dgt) 2~40MΩ: ±(2.0%rdg+4dgt) 40~110MΩ: ±(8.0%rdg+4dgt) 1.1000kΩ 0.1Ω 11.000kΩ 1Ω 110.00kΩ 10Ω 1.1000MΩ 100Ω 1

SEW 4338 mO ● Protection fuse:

200mA/250V × 1 ● Dimensions : 250(L) × 190(W) ×126(D)mm ● Weight : Approx. 1848g (battey included) ● Power source : 1.5V "C" battery × 8 ● Low Battery Indication : " " sign appears on the display when the battery voltage drops below accurate operating level. ● Accessories : Instruction Manual Test leads Shoulder belt Batteries B

SEW 4338 mO 6. INSTRUMENT LAYOUT

(1) (5) (3) (7) (2) (6) (8) (4) (9) (10) (11) MAX MIN HOLD REL TEST TEST ON DIGITAL MILLIOHM METER AND RESISTANCE TESTER OFF 1100.0mΩ 11000mΩ mΩ (AUTO) 110MΩ 110.00Ω LOCK ~ ● Test Leads ● Special Resistance Test Lead (Specialized for 2-wire resistance testing)

(1) C1 Termianl

This is the C1 terminal which is used for mΩ measurement, for 1100.0mΩ and 11000mΩ (4-wire testing). (2) P1 Termianl This is the P1 terminal which is used for mΩ measurement, for 1100.0mΩ and 11000mΩ (4-wire testing). (3) P2 Termianl This is the P2 terminal which is used for mΩ measurement, for 1100.0mΩ and 11000mΩ (4-wire testing). This terminal is also the COM terminal for resistance measurement, for 110.00Ω~110M�

SEW 4338 mO (4) C2 Termianl

This is the P2 terminal which is used for mΩ measurement, for 1100.0mΩ and 11000mΩ (4-wire testing). This terminal is also the COM terminal for resistance measurement, for 110.00Ω~110MΩ (2-wire testing). (5) Ω Terminal This is the positive input termial for resistance measurement, for 110.00Ω~110MΩ(2-wire testing). (6) Function Rotary Switch The function rotary switch is for selecting different functions. (7) TEST Button

(9) REL Button

In REL mode, the LCD displays DN+K-DN, where DN=1,2,3,..., DN is the last value before REL is pushed, and DN+K is the current value. If REL is pushed again in REL mode, the meter displays the reference value. The meter returns to normal operation if REL is pressed and held for longer than one second. Pressing HOLD in REL mode makes the meter stop updating the reading on the LCD. (10) HOLD Button HOLD mode makes the meter stop updating th

SEW Measuring Instruments Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
ST-2001

ST-2001 (Measuring Instruments ePDF User Manual, #1PU1YV)

13 443 67 13-04-2026
2950 CL

#R255QO: 2950 CL Measuring Instruments Instruction manual

13 743 119 21-05-2026
4338 mO

User Manual: SEW 4338 mO (ZW5SD9, Upd.10-06-2026)

16 992 189 10-06-2026
6213A-IN

PDF User Guide (@IK1MU8), SEW 6213A-IN Measuring Instruments (13-07-2026)

24 400 80 13-07-2026
3800 CL

User Guide: SEW 3800 CL (J1D6EC, Upd.23-08-2026)

12 677 109 23-08-2026
PT-30

#8OH9VV: PT-30 Measuring Instruments Instruction manual

12 1293 220 19-04-2026

Measuring Instruments: Similar Manuals