TELEPHONE LINE INTERFACE Please follow the instructions in this manual to obtain the optimum results from this manual. We also recommend you to keep this manual handy for future reference. TOA Corporation TD-600 ...
2. Intercom line connection 3. Telephone line connection 4. Facsimile connection Exchange DIP switch setting and programming Signal mode adjustment and setting 1. Receiving sound volume adjustment 2. Adjustment of current supplied to telephone 3. Jumper wire connection 4. Polarity reverse signal control Call operations Installation Specifications Accessories GENERAL DESCRIPTION By using the TD-600 telephone interface in conjunction with TOA' s intercom exchange, a pushphone (*DTMF) can be used as a handset intercom station. Two pushphones can be connected per interface. 2 3 4 ...
Power supply terminal CH2 intercom line terminal CH2 telephone line terminal CH1 intercom line terminal CH1 telephone line terminal – 3 – ...
24V DC power supply [AD-242A (2.5A) etc] TD-600 2. Intercom line connection 2.1 When using EXES-6000 exchange CH2 intercom line terminal CH1 intercom line terminal Twisted pair cable etc. EXES-6000 series exchange BX-610/620 YR-810/801 TD-600 – 4 – ...
EX-200 exchange CH2 intercom line terminal TD-600 intercom line terminal Twisted pair cable etc. LM-20 Perform jumper wire settings as instructed in page 9. Telephone line connection CH2 telephone line terminal TD-600 CH1 telephone line terminal DTMF telephone Usable telephones 1) DTMF type 2) Type with line impedance of 600 2.2 3. – 5 – Note: ...
To facsimile line terminal Facsimile CH2 telephone line terminal Usable facsimiles are restricted that selecting signal is transmitted a pushphone. EXCHANGE DIP SWITCH SETTING AND PROGRAMMING All the lines or exchanges to connect the TD-600 should be set to the continuous call tone. 1. When using EX-200 exchange Perform the handset station registration with the station No. 24. Handset station No. Handset station No. 2. When using EX-600 exchange Set the DIP swtich (SW-B-1) of CP-60 to ON to select the continuous call tone. 3. When using EX-610/620/630 exchange Set the DIP swtich (SW-E-8) of CP-66 ...
Perform the signal mode setting before the final installation or wiring work because the setting requires the removal of the top cover. Remove side plate screws (four places). Detach the top cover. 1. RECEIVING SOUND VOLUME ADJUSTMENT The receiving sound volume can be adjusted in 8dB steps by switching SW3 setting as shown in the figure below. Position of SW3 is factory-preset to "1". Note: Position of SW3 1 2 3 4 Receiving sound volume step 0dB + 8dB + 16dB + 24dB Position 1 of SW3 is set to 0dB. [Rear] [Front] – 7 – ...
The distance between the TD-600 and telephone can be made greater by making switch positions of both SW1 and SW2 identical to adjust the current to be supplied to the telephone. See the table below. The line loop resistance is factory-preset to 0~1500 Positions of SW1/SW2 1 2 3 Line loop resistance ( ) 0~1500 1500~2000 2000 or more [Rear] [Front] – 8 – ...
Referring to Table 1, change settings of jumper wires JP1-JP3. All jumpers are factory-preset to the EXES-6000' s settings. EXES-6000 EX-200 Jumper installed JP1 JP2 JP3 Jumper installed Jumper not installed Cut jumper Cut jumper Install jumper [Rear] [Front] 3. Table 1 Exchange Jumper – 9 – ...
When connecting the telephone line terminal to equipment that must not receive the polarity reverse signal, install the jumper wire in place marked with JP4 in the figure. Jumper JP4 is not factory-preset because the polarity reverse signal is set to transmit from the CH1 or CH2 telephone line terminal. [Rear] [Front] CALL OPERATIONS (1 )Lift up the handset and confirm that a dial tone is audible. Dial the desired station number within 10 seconds. (2)Replace the handset when terminating the conversation. (3)The intercom station's dial key corresponds to dial key of the pushphone. [Example] Intercom station Pushphone ( ...
M5 Rack mounting screw Fiber washer Rack mounting bracket M3 Binding head screw M3 Washer Unit can not be built in the inside of EX-610/620 exchanges. Mount it using the optional CR-271N or CR-392N cabinet rack. Desk-top application Rubber foot Attach supplied rubber feet to holes ( ø 2.5mm) on the bottom surface (four places). – 11 – ...
Rack mounting screw (M5x12 tapping screw) Fiber washer Binding head screw (M3x6) M3 washer Rubber foot Installation manual 2 4 4 4 4 4 1 TOA Corporation KOBE, JAPAN 133-06-171-00 Operating voltage Current consumption Applicable telephone Permissible line resistance Frequency response Max. output signal level Line output DC voltage Ringing tone Line capacity Line connection Installation method Ambient temperature range Dimensions Finish Weight + 24V DC (20V~28V) 250 mA max. DTMF type 2500 (loop) 300~3400 Hz -10 dBm -48V 75V, 16Hz 2 lines Screw terminal Desk top or rack mounting 0°C~40°C (32 0F~104 0F) 4 ...
Intercom System PDF Instructions
Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference. Note: For operation of the units, refer to the VS-900 operating instructions. RS-190 RS-191 SUBS User instruction manual for the Toa RS-190 Other. The guide describes usage and firmware updates, shutdown procedures, operating modes.
9330-7101-001 Rev F,1/01 INSTALLATION INSTRUCTIONS KP96 / KP97 SERIES KEYPANELS WITH EKPD96 / EKPD97 EXPANSION PANELS AND LCP-100A LEVEL CONTROL PANEL ADAM™, ADAM™ CS, AND ZEUS™ INTERCOM SYSTEMS DIR PROD RACK PL01 IFB4 TD AD NEWS SAT1 TEL1 TEL2 FLOR CHYR Device technical manual for the Telex KP-96 Intercom System. It details operating modes and device operation tips, power requirements, daily usage, wiring setup.
This Auto Dialer is a single channel voice dialer that can be used with any device that can provide a normally open or normally closed contact. The Auto Dialer can be programmed to store up to four numbers to dial, including standard (voice) telephones, most c Device instruction guide for the SJE Rhombus Auto Dialer Intercom System. The manual describes network configuration, safety guidelines, backup procedures.
1 Carefully unpack box. 1 of 4 We recommend mounting Ascent X1 on a standard gooseneck pedestal. If using alternate mounting, the optional Ascent 10' Cable Extension (p/n 16-X-EXT) must be purchased. Follow the instructions included with the extension before m Complete instruction guide for the AAS Ascent X1 Intercom System. It provides instructions for calibration steps, wiring setup, specifications, startup procedures.