Timeguard TG77 Installation & Operating Instructions Manual

Text of the manual

1. General Information

These instructions should be read carefully and retained for further reference and maintenance. 2. Safety • Do not plug in any appliance that exceeds the capacity of the Timer. • Always ensure the plug of any appliance is fully inserted into the timer outlet. • If cleaning of the timer is required, remove from mains power and w

3. Technical Specifications

• 230V AC 50 Hz • Switch Rating: 13A Resistive (3kW) 400W Filament Lighting 100W Fluorescent Lighting 60W LED lighting • 24 hour and 7 day programming • 20 ON/OFF programmes operating over a wide choice of day groups and individual days. • Manual Override until the next programme change • Manual Override for continuo

Returns TG77 to

operating mode with clock time displayed Decreases hours, minutes, days/day groups during programming and setting clock time Increases hours, minutes, days/day groups during programming and setting clock time Initiates countdown time period Initiates random delay to both start time and stop time of every programme Increments

4. Charging Battery

and Resetting • Plug the TG77 into a live socket for 4 hours to fully charge the battery, in order to bring the display ON (if blank). • Press reset button, marked ‘R’ on diagram A, using a pointed object (e.g. a pencil). The display will show its full set of characters and clear to show; Note: The colon between hours and minut

• Press and hold the ‘SET’ button until the day of the

week indicator, located in the top left hand corner of the display, starts flashing. Release the button. • Press the right arrow button ‘→’ to select the current day of the week and press the ‘SET’ button to save. The hour digit will start to flash. • Press the right arrow button �

Changing from 24 hour

to AM/PM format Note: The default time format will be 24 hour. Changing format will affect both the time display and the ON/OFF times you programme. • Press and hold the ‘TIME’ button for around 3 seconds until the time has changed from 24 hour to AM/PM format, then release the button. • To change back to 24 hour format, follo

Note: 20 ON/OFF programmes are available.

Any number up to 20 can be programmed, unused programmes must be left blank (– – : – –) and not programmed with zeros. Decide what ON/OFF times you would like to programme and which days they will operate on. You are able to programme ON/OFF times to operate over the following d