SCHMIDT® Flow Sensor

SS 20.600 Ex - Supplementary instructions for use in explosive atmospheres ATEX

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 2

SCHMIDT® Flow Sensor SS 20.600 Ex – ATEX version Table of Contents 1 Important information....................................................................... 3 2 Storage and transport ...................................................................... 4 3 Safety instructions for explosive atmospheres ................................ 5 4 Application range ....

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 3

1 Important information The present instructions for use contain all ATEX specific information for fast commissioning and safe operation of the version of SCHMIDT® Flow Sensor SS 20.600 Ex suitable for ATEX:  Please also read the "Instructions for Use SS 20.600" (material no.: 535084.02), because the present instructions for use are supplemen- tary instructions for

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 4

2 Storage and transport Packaging The device is protected by its packaging. The packaging is environmen- tally safe and recyclable. Basically, the following materials are used:  cardboard box  polyethylene foam or polyethylene film Dispose of the available packaging parts by submitting it to a recycling company. Conditions for storage and transport The following

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 5

3 Safety instructions for explosive atmospheres The following standards and rules are relevant: o EN 1127-1: Explosion prevention and protection – Part 1: Basic concepts and methodology o TRBS series o Standards for explosive gas atmospheres ("G"): - EN 60079-10-1: Classification of explosive atmospheres - EN 60079-14: Electrical apparatus for explosive atmospheres -

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 6

4 Application range The ATEX version of the SCHMIDT® Flow Sensor SS 20.600 Ex (cate- gory 3) is designed for stationary measurement of the flow velocity as well as the air and gas temperature in potentially explosive atmospheres with the following types of protection for: Gases (Zone 2) : II 3G Ex nA ic IIC T4 Gc Special condition for use ("X"): o The internal intrins

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 7

5 Mounting instructions Prior to the assembly in explosive atmospheres, the following safety measures must be observed:  Check if the device category corresponds to the specified zones.  Check if the operation approval of the operator is available.  Check if there is an explosive atmosphere during assembly, maintenance, etc.  Compliance with the applicable

SS 20.600 Ex – Supplementary instructions for use in explosive atmospheres ATEX Page 8

Figure 5-1 Grounding contacts (red), remote version Figure 5-2 Grounding contacts (red), compact sensor