Philips AC3829 Operation & User’s Manual

File Specifications

Brand: Philips
Category: Air Cleaner
Model: AC3829 (Operation & User’s Manual), pr2fC.tdr3AWM
File Type: PDF
File Size: —
Pages: 234 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (234 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 15/07/2026).

Read Online

Read the Philips AC3829 Operation & User’s Manual online using the built-in PDF viewer.

Key Pages of Document

© 2019 Koninklijke Philips N.V.

All rights reserved. 4241 210 95735 EN User manual 1 DA Brugervejledning 23 DE Benutzerhandbuch 45 ES Manual del usuario 70 FI Käyttöopas 93 FR Mode d’emploi 115 IT Manuale utente 139 NL Gebruiksaanwijzing 163 NO Brukerhåndbok 187 SV Användarhandbok 208 1 22 B H J I K L A G F E D C Control buttons Display panel AC3829 ...

1 2 2 hours 3S 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 3S 3S 1 3 4 5 6 10 9 8 7 11 12 13 14 22 20 19 18 17 16 15 21 ...

2 You air purifier

5 Product overview (fig a) 6 Controls Overview (fig b) 6 3 Get started 7 Installing the NanoProtect filter 7 Preparing for humidification 7 Wi-Fi connection 8 4 Use the appliance 9 Understanding the air quality light 9 Switching on and off 9 Setting the humidity level 9 Switching the operation mode 10 Using the light on/off function 10 Switching the display mode 10 Changing the Auto mode set ...

Read this user manual carefully before

you use the appliance, and save it for future reference. Danger • Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and/or a fire hazard. • Do not clean the appliance with water, any other liquid, or a (flammable) detergent to avoid electric shock and/ or a fire hazard. • Do not spray any flammable materials such as insecticides or fra ...

• Cleaning and user

maintenance shall not be made by children without supervision. • Children should be supervised to ensure that they do not play with the appliance. • Do not block the air inlet and outlet, e.g. by placing items on the air outlet or in front of the air inlet. • Standard WiFi interface based on 802.11b/g/n at 2.4 GHz with a maximum output power of 31.62 mW EIRP. Caution • This appliance is not a substitute for proper ...

• Do not insert your fingers

or objects into the air outlet or the air inlet to prevent physical injury or malfunctioning of the appliance. • Do not use this appliance when you have used indoor smoke-type insect repellents or in places with oily residues, burning incense, or chemical fumes. • Do not use the appliance near gas appliances, heating devices or fireplaces. • Always unplug the appliance after use and before filling water, cleaning, ...

• If you do not use the

humidification function for a long time, clean the water tank and NanoCloud rotary humidification wick tray, and air dry the NanoCloud rotary humidification wick. • If you need to move the appliance, disconnect the appliance from the power supply first. Then empty or remove the water tank and water tray. Carry the appliance horizontally by the handles on both sides of the appliance. • Unplug the appliance during f ...

Power on/off button

Child lock button Auto mode button Fan speed button Humidity setting button Light dimming button 2-in-1 mode on/off button Timer/Reset button Display panel: Sleep mode Auto mode Allergen mode Purification ONLY mode 2-in-1 mode Filter replacement alert Water refill alert Pre-filter and wick cleaning alert PM2.5 display Indoor Allergen Index display WiFi indicator Product overview (fig a) A C ...

Pull out the water tank (fig j).

2 Lift the water tray upwards and pull it out horizontally (fig k). 3 Remove all packaging material of the NanoCloud rotary humidification wick (fig l). Note • The humidification wick has been assembled on the wick wheel upon purchase. 4 Place the wick wheel on the wick support (fig m). Note • When placing the wick wheel on the wick support, make sure that the projections on t ...

Setting up the Wi-Fi connection

for the first time 1 Download and install the Philips "Clean Home+" app from the App Store or Google Play. 2 Put the plug of the air purifier in the power socket and touch to turn on the air purifier. » The Wi-Fi indicator blinks orange for the first time. 3 Make sure that your smartphone or tablet is successfully connected to your Wi-Fi network. 4 Launch the "Clean Home+" app and click on "Connect a ...

4 Use the

appliance Understanding the air quality light IAI level Air quality light color Air quality level 1-3 Blue Good 4-6 Blue-Purple Fair 7-9 Purple-Red Poor 10-12 Red Very poor The air quality light automatically goes on when the appliance is switched on, and lights up all colors in sequence. In a short time the air quality sensors select the color that corresponds to the ambient air quality. Switching on and off 1 Put the plug in the po ...

Switching the display

mode The appliance has three display modes, PM2.5 display, IAI display and humidity level display. PM2.5 AeraSense sensing technology accurately detects and quickly respond to even the slightest particle change in the air. It provides you with reassurance with real-time PM2.5 feedback. IAI The professional-grade AeraSense sensor detects the level of indoor air allergen and with numerical feedback from 1 to 12 the potential risk ...

Changing the Auto mode

setting You can choose the auto mode ( ), the Allergen mode ( ) and the sleep mode ( ). Auto mode In Auto mode, the appliance selects the fan speed in accordance with the ambient air humidity and air quality. • Touch the fan speed button to select Auto mode (fig x). » Auto ( ) and display on the screen. » The appliance operates in Auto mode by default. Allergen mode The extra-sensitive Allergen mode is designe ...

• Always unplug the appliance before

cleaning. • Never immerse the appliance in water or any other liquid. • Never use abrasive, aggressive, or flammable cleaning agents such as bleach or alcohol to clean any part of the appliance. • Only the pre-filter and NanoCloud rotary humidification wick are washable. The NanoProtect filter is not washable nor vacuum cleanable. Cleaning schedule Frequency Cleaning method When necessary W ...

Cleaning the body of the

appliance Regularly clean the inside and outside of the appliance to prevent dust from collecting. 1 Wipe away dust with a soft dry cloth from the body of the appliance. 2 Clean the air outlet with a soft dry cloth. Cleaning the air quality sensor Clean the air quality sensor every 2 months for optimal functioning of the purifier. Clean them more frequently if you use the purifier in a dusty environment. Note • When ...

• Make sure that the pre-filter is

completely dry. If it is still wet, bacteria may multiply in it and shorten the lifetime of the pre-filter. 5 After the pre-filter is completely dry, place it back into the back panel (fig h). 6 Touch and hold for 3 seconds to reset the pre-filter cleaning time. Descaling the NanoCloud rotary humidification wick Filter alert light status Follow this F0 displays on the screen and wick& pre-filter cleaning ale ...

6 Replace the

filter and wick Understanding the healthy air protect lock This appliance is equipped with the healthy air protect lock to make sure that the Nano protect filter and the humidification wick are in optimal condition when the appliance is operating. When the Nano protect filter and the humidification wick are almost expired, the replacement light flashes and the filter code displays on the screen (see Filter alert chart). If you d ...

Filter alert chart

Filter alert light status Follow this A3 displays on the screen Replace NanoProtect filter HEPA Series 3 (FY2422) C7 displays on the screen Replace the NanoProtect filter Active Carbon (FY2420) A3 and C7 display on the screen alternately Replace both filters Replace the NanoProtect filter when flashes on the screen (fig ‹). 1 Remove the used NanoProtect filter from the appliance (fig Œ). Note • Do not touch the pleated filter ...

• When placing the wick wheel on the

wick support, make sure that the projections on the wick wheel falls into the corresponding grooves. 8 Place the water tray and water tank back into the appliance (fig n). 9 Touch and hold for 3 seconds to reset the NanoCloud rotary humidification wick lifetime counter. ...

This chapter summarizes the most common problems you could encounter with the

appliance. If you are unable to solve the problem with the information below, contact the Consumer Care Center in your country. Problem Possible solution The appliance does not work even though it is plugged in. • The filter replacement light has been flashing but you have not replaced the NanoProtect filter, and the appliance is now locked. In this cas ...