Whirlpool 1997 "E" Service Manual

Text of Whirlpool 1997 "E" Service Manual

1997 “E” Models

OVER-THE-RANGE MICROWAVE OVEN HOOD COMBINATION Printed in U.S.A. LIT4322167

THIS MANUAL CONTAINS INFORMATION NECES-

SARY FOR SERVICING THE WHIRLPOOL MICRO- WAVE OVEN HOOD COMBINATION , MODELS: MH7130XE MH7135XE MH9115XE THE MANUAL IS DESIGNED TO BE USED ONLY BY QUALIFIED SERVICE PERSONNEL. THE SERVICE INFORMATION IS ORGANIZED TO HELP YOU EAS- ILY FIND WHAT YOU NEED. CHECK YOUR LOCAL BUILDING CODE FOR THE PROPER MODE OF INSTALLATION. IN THE AB- SENCE OF LOCAL CODES, THIS UNIT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL E

© 1997 Whirlpool Corporation

Cooking Products Service Manual Original March, 1997 4322167 Page iii Page Important Safety Information ...............................................................................................................................v Theory Of Operation ......................................................................................................................................... 1-1 Componen

Component Description & Testing .................................................................................................................. 3-1

Important Safety Instructions .................................................................................................................... 3-1 The Thermal Fuses.....................................................................................................................................
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March, 1997 4322167 Page v IMPORTANT SAFETY INFORMATION WHIRLPOOL ASSUMES NO RESPONSIBILITY FOR ANY REPAIRS MADE ON OUR PRODUCTS BY ANYONE OTHER THAN AUTHORIZED WHIRLPOOL SERVICE TECHNICIANS. Fire Hazard Do not obstruct the flow of ventilation air. Electrical Shock Hazard It is the customer’s responsibility to: • Contact a qualified electrical i

WARNING TO SERVICE TECHNICIANS

• Proper operation of the microwave ovens requires that the magnetron be properly assembled to the waveguide and cavity. Never operate the magnetron unless it is properly installed. • Be sure the “RF” seal is not damaged, and assembled around the magnetron dome properly when installing the magnetron. • Routine service safety procedures should be exercised at all times. • Untrained
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March, 1997 4322167 Page vii CAUTION: BEFORE TOUCHING ANY OVEN COMPONENTS OR WIRING, ALWAYS UNPLUG THE OVEN FROM ITS POWER SOURCE AND DISCHARGE THE CAPACITOR BY USING A 20,000-OHM DISCHARGE RESIS- TOR. OR USE AN INSULATED PLASTIC- HANDLE SCREWDRIVER AND SHORT ACROSS THE CAPACI- TOR TERMINALS. CAUTION CAUTION: REPLACE BLOWN FUSE WITH 15 AMPE

R.F. LEAKAGE TEST

CAUTION EQUIPMENT • Electromagnetic energy leakage monitor (NARDA 8100B, HOLADAY H1501). • 600 ml glass beaker. • Glass thermometer 100°C or 212°F. TEST On every service call, checks for microwave energy emission must be made according to the following manner. 1. Remove the cooking rack from the oven cavity, if the microwave oven is so equipped. 2. Place a 250 ML (8.0 oz.) glass of water in the center of the oven bottom. 3. S
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March 1997 4322167 Page 1-1 THEORY OF OPERATION The microwave oven is powered by the 120- volt line. Whenever the door is closed and a cooking function is programmed through the control panel’s keypad, relay contacts on the control board close, and complete a circuit from the L1 side to the neutral side of the line. The control board uses five relays to ope

The normally-closed (N.C.) contacts of relay 4 provide a potential circuit for the Base Thermal

Fuse. If the base of the oven exceeds 133˚F, the thermal fuse contacts close, and a circuit for the low-speed side of the blower motor is completed, which turns the motor on. The low-speed blower will operate until the base temperature drops below 104˚F and opens the thermal fuse contacts, and turns off. N L1 20A LINE FUSE CAVITY THERMAL FUSE MAGNETRON TH
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March, 1997 4322167 Page 2-1 COMPONENT SECTIONS Base Thermal Fuse ................................................. Closes @ 133˚F/56˚C, resets @ 104˚F/40˚C. Magnetron Thermal Fuse ......................................Opens @ 228˚F/109˚C, resets @ 140˚F/60˚C. Cavity Thermal Fuse ..............................................Opens @ 230˚F/110˚C, reset

REMOVING THE MICROWAVE OVEN & CABINET

WARNING Personal Injury Hazard Disconnect from the electrical supply be- fore servicing the unit. Failure to do so could result in death or electrical shock. 4. Support the front of the microwave oven and remove the two bolts and washers from the top of the oven. 5. Using two people, remove the microwave oven from its mounting location and set it on a protected (padded) work surface. 6. To remove the vent g
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March, 1997 4322167 Page 2-3 POWER CORD POWER CORD COVER BASE PLATE CONNECTORS CABINET TAB SLOTS CABINET SCREW VENT GRILLE SCREWS (2) CABINET SCREWS VENT GRILLE BASE PLATE SCREWS (6) COOKTOP LIGHT ASSEMBLY WIRING SLOTS Removing The Cabinet

Whirlpool 1997 "E" THE PROTECTION CONTROL SYSTEM

REMOVING THE OVEN DOOR WARNING Personal Injury Hazard Disconnect from the electrical supply be- fore servicing the unit. Failure to do so could result in death or electrical shock. 2. Remove the two screws from the top of the cabinet for the vent grille and remove the grille (see the illustration on page 2-3). 3. Open the oven door all the way, then lift the door pins out of the hinge holes and remove it. 4. Install the ne
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March, 1997 4322167 Page 2-5 REMOVING THE OVEN DOOR COMPONENTS WARNING Personal Injury Hazard Disconnect from the electrical supply be- fore servicing the unit. Failure to do so could result in death or electrical shock. 1. Disconnect the electrical supply to the microwave oven. 2. Remove the two screws from the top of the cabinet for the vent grille and remove

REMOVING THE CONTROL PANEL

WARNING Personal Injury Hazard Disconnect from the electrical supply be- fore servicing the unit. Failure to do so could result in death or electrical shock. 2. Remove the two screws from the top of the cabinet for the vent grille and remove the grille (see the illustration on page 2-3). 3. Remove the screw from the top center tab of the control panel, then lift the panel so that the bottom tabs are out of the slots and pull
© 1997 Whirlpool Corporation Cooking Products Service Manual Original March, 1997 4322167 Page 2-7 REMOVING THE LINE FUSE WARNING Personal Injury Hazard Disconnect from the electrical supply be- fore servicing the unit. Failure to do so could result in death or electrical shock. 2. Remove the two screws from the top of the cabinet for the vent grille and remove the grille (see the illustration on page 2-3). 3. Remove the control

Whirlpool 1997 "E" REMOVING/ADJUSTING THE INTERLOCK SWITCHES

WARNING Personal Injury Hazard Disconnect from the electrical supply be- fore servicing the unit. Failure to do so could result in death or electrical shock. REMOVING A SWITCH 1. Disconnect the electrical supply to the microwave oven. 2. Remove the two screws from the top of the cabinet for the vent grille and remove the grille (see the illustration on page 2-3). 3. Remove the control panel from the micro- wave

Whirlpool Microwave Oven Owners Instructions: