Viessmann VITOGAS 100 Technical Data Manual

Text of the manual

Cast iron hot water heating boiler

90 to 240 MBH/26 to 70 kW 5167 462 v1.5 02/2011 Vitogas 100 with boiler stand beside Vitocell-V 100 domestic hot water storage tank Vitogas 100 Technical Data Manual Model Nos. and pricing: see Price List Vitogas 100 GS1 Series – residential, fully assembled boiler Natural Gas-/Propane-Fired, Single-Stage Boiler cast iron sectional construction atmospheric, fully premix burner Heating input: 90 to 240 MBH 26 to 70 kW

Top performance in a small package. Thanks

to its compact dimensions, the Vitogas 100 is ideal for installation in closets and alcoves. Apart from saving space, the Vitogas 100 is economical in terms of energy consumption with reduced emissions. The benefits at a glance:  High operational reliability and a long service life due to special high-grade gray cast iron with lamellar graphite and a low thermal load on the heat exchanger surface.  Clean combustion due to atmospheric premix burner with super-stoichiometric premixing: NOx < 27.9 ppm (air-free), CO < 9.2 ppm (air-free). The Vitogas 100 therefore meets the toughest emission requirements in North America, such as California regulations (SMAQMD).  Economical and environmentally friendly operation via modulating boiler water temperatures. Annual fuel utilization efficiency (A.F.U.E.) of up to 85.6 %.  Intermittent pilot ignition system provides soft, quiet and extremely reliable ignition.  Compact dimensions – therefore suitable for installation in a boiler room, a utility room or even in an open living area.  Problem-free transport into difficult-to-access boiler rooms due to light weight and compact design. Heat exchanger surfaces of special high-grade gray cast iron for high operational reliability and a long service life 5167 462 v1.5

Product may not be exactly as illustrated.

3 Extremely effective Heat exchanger surfaces of Vitotronic – the new insulation special high-grade gray cast generation of boiler controls: iron with lamellar graphite Intelligent, easy to install, operate and service Stainless steel atmospheric A redundant gas super-stoichiometric valve doubles premix burners for low- operational safety emission combustion 5167 462 v1.5

CSA output /

DOE heating capacity MBH kW 76 22 98 29 123 36 140 41 161 47 203 60 Net I=B=R rating*1 MBH kW 66 19 85 25 107 31 122 36 140 41 177 52 Heat exchanger surface area ft2 m2 16.25 1.51 21.42 1.99 26.48 2.46 31.54 2.93 36.60 3.40 46.82 4.35 Min. gas supply pressure Natural gas Liquid propane “w.c. “w.c. 5 11 5 11 5 11 5 11 5 11 5 11 Max. gas supply pressure*2 “w.c. 14 14 14 14 14 14 A.F.U.E.*3 % 85.6 85.5 85.5 85.5 85.5 85.4 Overall dimensions*4 Overall length Overall width Width Overall height (operation) – Height 1 (control unit in position for operation) – Height 2 (control unit in position for servicing) Height incl. flue pipe elbow Height of boiler stand Height of DHW tank positioned under the boiler – 42 to 53 USG/ 160 to 200 liter capacity inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm 33¼ 844 25½ 650 21½ 546 33¼ 845 37½ 955 46½ 1180 39 992 9¾ 250 26 660 33¼ 844 25½ 650 21½ 546 33¼ 845 37½ 955 46½ 1180 39¾ 1012 9¾ 250 26 660 34 864 33 840 29 736 33¼ 845 37½ 955 46½ 1180 39¾ 1012 9¾ 250 26 660 34 864 33 840 29 736 33¼ 845 37½ 955 46½ 1180 39¾ 1012 9¾ 250 26 660 34 864 36½ 930 32½ 826 33¼ 845 37½ 955 46½ 1180 42½ 1082 9¾ 250 –– 34 864 43¾ 1110 39½ 1006 33¼ 845 37½ 955 46½ 1180 42½ 1082 9¾ 250 –– Weight, boiler with insulation, lbs burner and boiler control unit kg 273 124 326 148 375 170 428 194 481 218 582 264 Boiler water content USG ltr 2.6 9.7 3.1 11.7 3.6 13.8 4.2 15.9 4.7 17.9 5.8 21.9 Max. operating pressure psig 60 60 60 60 60 60 Number of intermediate cast iron sections 2 3 4 5 6 8 Number of burners 3 4 5 6 7 9 5167 462 v1.5

Technical data (continued)

Boiler connections Boiler supply and return Safety supply Drain valve ” (male thread) ” (male thread) ” (male thread) 1½ 1½ ¾ 1½ 1½ ¾ 1½ 1½ ¾ 1½ 1½ ¾ 1½ 1½ ¾ 1½ 1½ ¾ Gas supply connection ” (NPT) ½ ½ ½ ½ ½ ½ Flue gas*5 Temperature (gross) Mass flow rate – with natural gas – with liquid propane °F °C lbs/h kg/h lbs/h kg/h 230 110 161 73 148 67 230 110 216 98 209 95 235 113 236 107 209 95 266 130 231 105 223 101 230 110 342 155 322 146 252 122 353 160 337 153 Vent pipe collar outside Ø” 5 6 6 6 7 7 *1Net I=B=R rating based on piping and pick-up allowance of 1.15. *2If the gas supply pressure is higher than the maximum permissible value, a separate gas regulator must be installed upstream of the boiler system. *3With intermittent pilot electronic ignition system and vent damper. *4Height dimensions for Vitogas 100 include leveling bolts. *5Measured flue gas temperature after dilution air with combustion air temperature of 68 °F/20 °C.  For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product. 5167 462 v1.5

Other Boiler Manuals