Viessmann Vitocal 200-S Installation And Service Instructions Manual

File Specifications

Brand: Viessmann
Category: Heat Pump
Model: Vitocal 200-S (Installation And Service Instructions Manual), pr8SyaA8FOzSc
File Type: PDF
File Size: 11.49 Mb
Pages: 152 pages

Download Document

Get a high-quality, printable PDF version of this manual for offline use.

Download PDF Manual (152 pages)

⚠️ Download Safety: This PDF is completely safe to download (last scan date: 15/05/2026).

Read Online

Read the Viessmann Vitocal 200-S Installation And Service Instructions Manual online using the built-in PDF viewer.

Key Pages of Document

Installation and service

instructions for contractors VIESMANN Vitocal 200-S Type AWB 201.B04 to B13 Air source heat pump, split version for heating operation Type AWB-AC 201.B04 to B13 Air source heat pump, split version for heating and cooling opera- tion For applicability, see the last page VITOCAL 200-S 5623 611 GB 10/2012 Please keep safe. ...

Please follow these safety instructions closely to prevent accidents and mate-

rial losses. Safety instructions explained Danger This symbol warns against the risk of injury. ! Please note This symbol warns against the risk of material losses and envi- ronmental pollution. Note Details identified by the word "Note" con- tain additional information. Target group These instructions are exclusively inten- ded for qualified contractors. ■Work on the refrig ...

Electronic assemblies can be

damaged by electrostatic dis- charge. Before beginning work, touch earthed objects, such as heating or water pipes, to discharge static loads. Repair work ! Please note Repairing components that fulfil a safety function can compromise the safe operation of your sys- tem. Defective components must be replaced with genuine Viessmann spare parts. Auxiliary components, spare and wearing parts ! Please note Spare and ...

Preparing for installation

Application............................................................................................................ 6 Requirements regarding on-site connections....................................................... 7 Overview of possible system schemes................................................................ 9 Markings in the system examples.................................................. ...

Electrical equipment, external unit, type AWB/AWB-AC 201.B10, B13............... 124

Hydraulics, external unit, type AWB/AWB-AC 201.B10, B13............................... 126 Commissioning/service reports Hydraulic parameter report................................................................................... 128 Control parameters report.................................................................................... 128 Specification........... ...

The heat pumps Vitocal 200-S,

type AWB and AWB-AC can be used for the following purposes: ■Central heating via a heating system ■Central cooling (only type AWB-AC) via a heating system ■DHW heating Any use that differs from or goes beyond this is considered inappropriate. Note Vitocal 200-S is intended exclusively for domestic use, i.e. even people who have not had any instruction are able to oper- ate the appliance safely. Preparing for installati ...

Preparing for installation

Requirements regarding on-site connections 5623 611 GB Installation ...

Refrigerant lines from/to the

external unit: Type AWB/ AWB-AC Pipe 7 UNF thread ■Hot gas line 201.B04 12 mm ⅞ Reducer ⅞ x ¾ 201.B07 201.B10 201.B13 16 mm 16 mm 16 mm ⅞ ⅞ ⅞ ■Liquid line 201.B04 6 mm ⅝ Reducer ⅝ x ⁷⁄₁₆ 201.B07 201.B10 201.B13 10 mm 10 mm 10 mm ⅝ ⅝ ⅝ DHW cylinder flow (heating water side) G 1¼ + Heating water return and DHW cylinder return G 1¼ Heating water flow G 1¼ A Cable ent ...

Recommended power cables

Vitocal 200-S, type AWB, AWB-AC 201.B04 201.B07 201.B10 201.B13 External unit (compressor) 230 V~ Cable cross-section 3 x 2.5 mm2 3 x 2.5 mm2 3 x 2.5 mm2 3 x 4.0 mm2 Max. cable length 29 m 25 m 20 m 20 m or or Cable cross-section – – 3 x 4.0 mm2 3 x 6.0 mm2 Max. cable length – – 32 m 30 m Heat pump control unit (inter- nal unit) 230 V~ Cable cross-section ■Without power-OFF 3 x 1.5 mm2 3 x 1.5 mm2 3 x 1.5 mm2 3 x 1.5 mm ...

Heating water buffer cylinder

— 0 0 X X X X — External heat source 0 0*1 0*1 0 0 0 0 — Instantaneous heating water heater (type AWB-AC only) X X X X X X X — Swimming pool — 0 0 0 0 0 0 — Cooling (only type AWB-AC) A1/HC1 — 0 0 — ...

System example 1, ID: 4605169_1202_05

Note This scheme is a general example with- out shut-off valves or safety equipment. This does not replace the need for local engineering. Preparing for installation Markings in the system examples 5623 611 GB Installation ...

Hydraulic installation scheme

CW DHW 60 61 71 70 73 74 76 77 91 90 96 1 29 14 55 3 62 54 52 50 53 37 31 30 2 --2/212.3-- --2/F13-- --2/F0-- --2/F20-- --2/F6-- --2/222.1;2-- --2/F4-- --2/212.2-- --2/224.7-- -2/222.4--51- --212.3-- --222.1;2-- --224.7-- --212.2-- --222.4-- --F6-- --F20-- --F0-- --F13-- --F4-- -2/211.2--6--51- 4 5 6 --105/52-- --74/20-- -105/20--76- --105/2-- --KM BUS-- --211.2-- --230 V-- --52-- --2-- -KM BUS- --20-- -230 V- 105 8 --145-- ...

Internal unit of heat pump Vitocal 200-S, type AWB 201.B or

type AWB-AC 201.B 2 Heat pump control unit Vitotronic 200, type WO1C 3 Outside temperature sensor ATS 4 Instantaneous heating water heater with switching module (only for Vitocal 200-S, type AWB-AC) 5 3-way diverter valve for "Central heating/DHW heating" 6 Secondary pump 8 KM BUS distributor qW Safety assembly qE Heating circuit expansion vessel qT Flow switch Pr ...

Heating water buffer cylinder

zQ Buffer temperature sensor Heating circuit with mixer M2 (KM BUS) uP Underfloor heating circuit/cooling circuit uQ Vitotrol remote control uE Flow temperature sensor uR Temperature limiter to restrict the maximum temperature of underfloor heating systems ■As immersion thermostat or ■As contact thermostat uZ Heating circuit pump uU 3-way mixer, heating circuit Mixer motor of 3-way mixer q-T Mixer ex ...

230 V/50 Hz

2 211.2 X2.N X1. UP 6 211.4 X2.N X1. 212.3 X2.N X1. 212.2 X2.N X1. HK A1 96 ZP 37 5 224.7 X2.N X1. UPSB 52 UV X2.N X1. 222.4 222.3 X3.1 51 222.2 X2.N X1. 54 222.1 OPEN CLOSE L3 N L2 L1 4 3/N/PE 400 V, 50 Hz STBs 55 1 2 145 8 145 145 145 145 40 145 52 2 1 2 N L UP M2 77 73 M 1~ 74 76 M2 VTS M2 20 230 V/50 Hz 105 2 1 HK A1 HK M2 91 71 Low voltage 1/N/PE 2 1 2 1 136 X2.N 211.3 224.4 2 130 W 130 W 50 W 100 W 100 W L N 55 STBs 20 X3.4 X3.3 15 HK ...

Instantaneous heating water heater 4

(only type AWB-AC), 3-way diverter valve 5 and secondary pump 6 are already installed and electrically connec- ted. 2 Low voltage F6 STS 31 F4 PTS 61 KTS 53 F20 F0 VTS 62 ATS 3 F13 NTC 10 kΩ NTC 10 kΩ NTC 10 kΩ NTC 10 kΩ NTC 10 kΩ Power supplies for the internal unit and instantaneous heating water heater N1 1/N/PE 230 V/50 Hz N1 N1 L1 4 L1 L1 3/N/PE 400 V/50 Hz N L2 4 L3 L1 230 V 400 V Instantaneous heatin ...

External unit connections

C N L 29 4 kW COM 43 V > 42 V 2 L1 N 1 / N / PE 230 V/ 50 Hz COM 29 7 kW COM 43 V > 42 V 2 L1 N 1 / N / PE 230 V/ 50 Hz Li No Lo Ni 29 COM 12 V 2 L1 N 1 / N / PE 230 V/ 50 Hz N L L N C1 C2 10 / 13 kW < 42 V Required parameter settings To call up "Coding level 1" for setting the parameters, see the commissioning assistant on page 85 and page 87. Preparing for installation System example 1, ID: 4605169_1202_05 (cont.) 5623 611 GB ...

■"System scheme 7000"

"6" "Compressor" ■"Output compressor stage 5030" Type AWB/AWB-AC ■201.B04: "4" ■201.B07: "7" ■201.B10: "10" ■201.B13: "13" "External heat source" ■"Enable external heat source 7B00" "1" ■"Enable external heat source for DHW heating 7B0D" "1" DHW heating: "Time program DHW heating" Set time program (see op- erating instructions) "Time program DHW circulation" (if a DHW circulatio ...

This scheme is a general example with-

out shut-off valves or safety equipment. This does not replace the need for local engineering. Preparing for installation System example 2, ID: 4605170_1202_05 5623 611 GB Installation ...

Hydraulic installation scheme

CW DHW 60 61 71 70 73 74 76 77 91 90 96 1 29 14 55 3 62 54 52 50 53 37 31 30 2 --2/212.3-- --2/F13-- --2/F0-- --2/F20-- --2/F6-- --2/222.1;2-- --2/F4-- --2/212.2-- --2/224.7-- -2/222.4--51- --212.3-- --222.1;2-- --224.7-- --212.2-- --222.4-- --F6-- --F20-- --F0-- --F13-- --F4-- -2/211.2--6--51- 4 5 6 --105/52-- --74/20-- -105/20--76- --105/2-- --KM BUS-- --211.2-- --230 V-- --2/211.5-- 89 89 -2/211.5- --211.5-- -2/X3.8;3.9- ...

Related Devices for Viessmann Vitocal 200-S:

3560
Viessmann 3560 Operation manual
13.03.2026 2 pages

Viessmann Modelltechnik GmbH Bahnhofstraße 2a D - 35116 Hatzfeld-Reddighausen www.viessmann-modell.de 4 Bedienungsanleitung Operation Manual 85901 Stand 02/sw Operation and maintenance manual for the Viessmann 3560 Cables and connectors. The document guides users through operating modes, installation guides, device overview, safety information.

VITOCELL 300V
Viessmann VITOCELL 300V Technical data manual
17.07.2026 16 pages

Technical Data Manual 5672 342 - 02 10/2015 Vitocell 300-V EVI Series Indirect-fired domestic hot water storage tank 53 USG to 119 USG (200 L to 450 L) capaci User documentation for the Viessmann VITOCELL 300V Water Heater. This guide explains technical procedures for safety information, reset instructions, product maintenance, basic operation.

Plasser & Theurer 09-3X
Viessmann Plasser & Theurer 09-3X Operation manual
30.07.2026 24 pages

Bedienungsanleitung Operation Manual Innovation, die bewegt! Schienen-Stopfexpress Plasser & Theurer 09-3X Tamping machine Plasser & Theurer 09-3X 1. Wichtige H Quick start guide for the Viessmann Plasser & Theurer 09-3X Toy. This guide offers instructions on device instructions, configuration options, system setup, system configuration.

VITOLIGNO 300-C
Viessmann VITOLIGNO 300-C Operating instructions manual
22.03.2026 52 pages

Step-by-step user manual for the Viessmann VITOLIGNO 300-C Boiler. The documentation includes details on operational safety, service contacts, setup, wiring setup.

4040
Viessmann 4040 Operation manual
03.04.2026 4 pages

Bedienungsanleitung Operation Manual Innovation, die bewegt! 1. Wichtige Hinweise / Important information....................................................... Technical instruction manual for the Viessmann 4040 Toy. The document includes daily usage, installation, performance guidelines, installation procedures.

Vitotrol 300
Viessmann Vitotrol 300 Installation instructions manual
03.06.2026 8 pages

5592 911 GB 6/2007 Dispose after installation. Installation instructions for contractors VIESMANN Vitotrol 300 Remote control for one heating circuit Part no. 7 Owner’s guide for the Viessmann Vitotrol 300 Remote Control. This guide includes device operation tips, wiring setup, internal layout.

5020
Viessmann 5020 Operation manual
27.05.2026 4 pages

Bedienungsanleitung Operation Manual Innovation, die bewegt! 5020 Elektronisches Schweißlicht Electronic welding light 1. Wichtige Hinweise / Important informa Instruction and usage manual for the Viessmann 5020 Welding System. It provides instructions for device features, detailing setup, user settings, installation procedures.

VITOTRONIC SPS
Viessmann VITOTRONIC SPS Service instructions manual
18.08.2026 68 pages

Service instructions for contractors Viesmann Vitotronic SPS Type 2.0 Heat pump control unit VITOTRONIC SPS 5839380 GB 10/2019 Please keep safe. User handbook for the Viessmann VITOTRONIC SPS Control Unit. This documentation explains configuration and safety protocols, setup tips, energy usage.

Heat Pump: Frequently Requested PDF Instructions

RXYQ72PYDN
Daikin RXYQ72PYDN Installation manual
30.03.2026 25 pages

INSTALLATION MANUAL System air conditioner RXYQ72PYDN RXYQ96PYDN RXYQ120PYDN RXYQ144PYDN RXYQ168PYDN RXYQ192PYDN RXYQ216PYDN RXYQ240PYDN English Françai Españ Maintenance instructions for the Daikin RXYQ72PYDN Air Conditioner. The guide offers support information and performance guidelines, network setup, device calibration.

MRV II AV08NMVERA
Haier MRV II AV08NMVERA Installation manual
05.07.2026 135 pages

              ! ! "# " $" " $" "$" "$" "%$" " $" " $" "$" "$" Product usage guide for the Haier MRV II AV08NMVERA Heat Pump. This reference includes service instructions, maintenance schedule, power requirements, component overview.

H150FD
Hayward H150FD Quick reference manual
04.06.2026 2 pages

Quick Reference Guide SAMPLE CERTIFIED Manifold Gas Pressure Maximum inlet gas pressure Minimum inlet gas pressure 10.0” 13.0” 7.0” 240VAC is the factory Operation instructions for the Hayward H150FD Heating System. The document presents setup guidelines, connectivity setup, supported accessories.

PACKAGE HEAT PUMP
Amana PACKAGE HEAT PUMP Owner's manual
20.04.2026 20 pages

Goodman Company, L.P. 1810 Wilson Parkway • Fayetteville, Tennessee 37334 www.amana-hac.com Installer: Affix literature adjacent to the unit. Part No. 107 User guidebook for the Amana PACKAGE HEAT PUMP Heat Pump. This guide offers instructions on network configuration, system parameters, maintenance guidelines.