Teledyne 6020 Operating Instructions Manual

Text of Teledyne 6020 Operating Instructions Manual

Teledyne Analytical Instruments

OPERATING INSTRUCTIONS Model 6020 Photometric Analyzer P/N M69610A 11/24/04 ECO # 03-0126 HIGHLY TOXIC AND OR FLAMMABLE LIQUIDS OR GASES MAY BE PRESENT IN THIS MONITORING SYSTEM. PERSONAL PROTECTIVE EQUIPMENT MAY BE REQUIRED WHEN SERVICING THIS SYSTEM. HAZARDOUS VOLTAGES EXIST ON CERTAIN COMPONENTS INTERNALLY WHICH MAY PERSIST FOR A TIME EVEN AFTER THE POWER IS TURNED OFF AND DISCONNECTED. ONL
Teledyne Analytical Instruments Copyright © 2000 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or computer language in whole or in part, in any form or by any means, whether it be electronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Analytical
Teledyne Analytical Instruments Table of Contents Part I: Control Unit ....................................... Part I Part II: Analysis Unit ................................... Part II Appendix......................................................... A-1

Part I: i

Part I: Control Unit Teledyne Analytical Instruments OPERATING INSTRUCTIONS Model 6020 Photometric Analyzer Part I: Control Unit Explosion Proof

ii: Part I

Model 6020 Photometric Analyzer Teledyne Analytical Instruments Table of Contents 1 Introduction 1.1 Overview ........................................................................ 1-1 1.2 Typical Applications ....................................................... 1-1 1.3 Main Features of the Analyzer ....................................... 1-1 1.4 Operator Interface .......................................................... 1-2 1.4.1 UP/DO

Part I: iii

Part I: Control Unit Teledyne Analytical Instruments 3.3.12 Manual Control of Filter & Solenoids ..................... 3-15 3.4 The Zero and Span Functions ....................................... 3-16 3.4.1 Zero Cal ................................................................. 3-16 3.4.1.1 Auto Mode Zeroing ........................................ 3-17 3.4.1.2 Manual Mode Zeroing.................................... 3-18 3.4.1.3 Cell Failu

Part I: 1-1

Photometric Analyzer Part I: Control Unit Teledyne Analytical Instruments Introduction 1.1 Overview The Teledyne Analytical Instruments Model 6020 Control Unit, to- gether with a 6020 Analysis Unit, is versatile microprocessor-based instru- ment. Part I, of this manual covers the Model 6020 Explosion-Proof, Bulk- head Mount Control Unit. (The Analysis Unit is covered in Part II of this manual. The Control Unit is for indoor/outdoor use in h

1-2: Part I

1 Introduction Model 6020 Teledyne Analytical Instruments • A 2-line alphanumeric display screen, driven by microprocessor electronics, that continuously prompts and informs the operator. • High resolution, accurate readings of concentration from low ppm levels through to 100%. Large, bright, meter readout. • Versatile analysis over a wide range of applications. • Microprocessor based electronics: 8-bit CMOS microprocessor with 32 kB

Teledyne Analytical Instruments Owners Instructions: