Extech Instruments 380943 High Resolution 60 Amp AC Clamp-on Meter

• 4000 Count Display with 10uA Resolution • 20 reading per second bargraph • Shielded transformer jaws • Selectable filter circuit • MAX/MIN, Relative, & Hold functions • 1.2” (30mm) jaw diameter Introduction Thank you for selecting the Extech 380943 AC Clamp Meter. This device is ideal for checking leakage, ground, and sheath current. This professional meter, with proper care,

Model 380943 Ver. 2.1 11/2002

2 Specifications General Specifications Display 3-3/4 digit (4000 count) LCD with 40 segment bargraph Functions ACA, ACV, Resistance, and Continuity Polarity Minus sign ( - ) indicates negative polarity Overload indication Left blinking digit Relative Mode ZERO front panel key Display rate 2 readings per second (20 readings per second for bargraph) Battery Two 1.5V AA batteries Operating conditions 4 0F to 122 0F (-10 0
Model 380943 Ver. 2.1 11/2002 3 Meter Description 1. Current sensing jaws 2. Jaws opening trigger 3. Function switch 4. Data HOLD key 5. MAX / MIN key 6. ZERO (Relative) key 7. LCD Display 8. Frequency select slide switch 9. Positive input terminal for V and Ω 10. Negative (COM) input terminal Safety Information ! Caution ! Refer to the explanation in this Manual Caution ! Risk of electric shock Earth (Ground) Double Insulation This meter has be
Model 380943 Ver. 2.1 11/2002 4 Operation Using the Frequency Selector Switch 50/60Hz position (low pass filter) Use the 50/60Hz position when measuring circuits with a frequency bandwidth of 50/60Hz. Since the meter has superior frequency response, measurement results may include higher frequencies and harmonics of the fundamental frequency. Putting this switch in the 50/60 position activates the meter’s low pass filter minimizing the affects of
Model 380943 Ver. 2.1 11/2002 5 Leakage Current on Unbalanced Loads Ground Conductor Leakage Single Phase 2-Wire Leakage Three Phase 3-Wire Leakage Three Phase 4-Wire Leakage AC Voltage Measurements WARNING: To avoid electric shock or damage to the meter, do not make any voltage measurements that exceed the maximum specified limits. 1. Set the Function switch to the Voltage position. 2. Set the Freq

Extech Instruments Measuring Instruments Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
407860

407860 Operation & user’s manual - 32W999

10 0.37 Mb 190 48 10-06-2026
RF153

RF153 (Measuring Instruments ePDF User Guide, #479X11)

22 261 42 10-06-2026
MO290

MO290 Operation & user’s manual - 327CX1

7 1244 224 28-07-2026
RH305

Measuring Instruments #52R632

7 210 42 20-07-2026
TKG100

Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 09-10-2026)

84 153 33 09-10-2026
407495

Measuring Instruments #N8CCM3

6 395 76 05-08-2026
MO260

Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 17-06-2026)

8 1439 346 17-06-2026
CO240

CO240 (Measuring Instruments ePDF User Manual, #RZZ2J6)

7 197 34 24-09-2026
EA31

PDF User Guide (@249216), Extech Instruments EA31 Measuring Instruments (12-05-2026)

7 184 39 12-05-2026
Oyster-16

#TUCO9K: Oyster-16 Measuring Instruments Operation & user’s manual

12 93 23 17-05-2026

Measuring Instruments: Similar Manuals