407860-EU-EN v2.7 3/14
2
Introduction
Congratulations on your purchase of the Extech 407860 Vibration Meter. The Model 407860
measures vibration levels in industrial machinery. Misalignment, poor balancing, structural
compromises, and other factors can cause unwanted vibration increases. The Model 407860 has
a frequency sensitivity that meets ISO-2954 and offers Displacement, Velocity and Acceleration
features. This meter is shipped fully tested and cali
407860-EU-EN v2.7 3/14 3
Meter Operation
Connecting the Probe
1. Note that this meter accepts only the supplied vibration probe.
2. Plug the BNC connector end of the probe cable onto the BNC connector at the top of the meter.
3. The probe can then be connected to the tested machinery in three ways.
a. Attach the magnetic end of the probe to a ferrous material on the equipment under test as
shown in the accompanying diagram.
b. Manually hold the probe in
407860-EU-EN v2.7 3/14 4
UNIT button
Press this button to select the measurement units desired.
Press and hold this button for > 5 seconds to switch from metric to imperial units.
Measurement
Metric Units
Imperial Units
Acceleration
m/s
2, G
Ft/s
2
Velocity
mm/s, cm/s
Inch/s
Displacement
mm
inch
HOLD button
Press this button to freeze the measured value in the display. HOLD will appear in the display.
Press the button again to return to normal operation.
407860-EU-EN v2.7 3/14 5
Datalogging
The internal datalogger memory can hold up to 500 readings. Readings can be logged manually,
with a button press, or automatically at a programmed sample rate.
Sample Rate
The sample rate can be set to 0 (manual), 1, 2, 5, 10, 30, 60, 600, 1800 or 3600 seconds.
1.
With the meter OFF, Press and hold the HOLD and REC buttons.
2.
Press the POWER button.
3.
When the display shows the sample rate, release the HOLD & REC bu
407860-EU-EN v2.7 3/14 6
Memory Full Indication
The meter produces a continuous tone when the internal memory has been filled to capacity (500
readings). The data can be viewed, cleared, or downloaded to a PC.
Viewing Stored Data
1.
With the meter OFF, Press and hold the HOLD and REC buttons.
2.
Press the POWER button.
3.
When the display indicates the existing sample rate, release the HOLD and REC buttons.
4.
The HOLD and the FUNCTION buttons are used t
407860-EU-EN v2.7 3/14 7
Battery Replacement
When the 9V battery weakens, the indicator appears on the LCD. Follow these steps to
replace the battery:
1.
Turn the meter OFF.
2.
Remove the probe and the RS-232 cable from the meter.
3.
Remove the protective rubber jacket that encases the meter by stretching it over the bottom of
the meter.
4.
Open the battery compartment (located on the lower back of the meter) with a flat head
screwdriver or c
407860-EU-EN v2.7 3/14 8
Specifications
General Specifications
Display
3-1/2 digit LCD with bar-graph
Frequency range
10Hz to 1KHz (frequency sensitivity meets ISO-2954)
Sampling time
One (1) second approx.
Data output
Isolated serial RS-232 PC Interface
Data Hold
Freezes displayed reading
Min/Max Memory
Meter stores highest and lowest readings for later recall
Data Logger
Store up to 500 readings
Data logger Sample Time 0 (manual), 1, 2, 5, 10, 30, 60,
407860-EU-EN v2.7 3/14 9
Appendix A: Machinery Classification
When evaluating machinery and equipment it is useful to know their classification range and group
type. There are four machine groups and classification ranges recognized internationally (ISO 2372
and VDI 2056). The limits for vibration severity (mm/s) are shown in the Tables below:
GROUP K – Small Machinery up to 15KW (for example, production motors)
Testing Status
Vibration Severity (mm/s)
407860-EU-EN v2.7 3/14 10
Appendix B: Relative Sensitivity Table (ISO 2954)
Frequency (Hz)
Relative sensitivity
Normal value
Minimum value
Maximum value
10
1.0
0.8
1.1
20
1.0
0.9
1.1
40
1.0
0.9
1.1
80
1.0
1.0
1.0
160
1.0
0.9
1.1
500
1.0
0.9
1.1
1000
1.0
0.8
1.1
Appendix C: Glossary
Vibration: Vibration is an oscillation or repetitive motion of an object around an equilibrium position.
Displacement: Displacement is the peak-to-peak distance from a referen
Extech Instruments Measuring Instruments Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated |
|---|---|---|---|---|---|---|
RF153 |
User Manual: Extech Instruments RF153 (NREECQ, Upd.12-04-2026) |
22 | 123 | 25 | 12-04-2026 | |
45160 |
45160 (Measuring Instruments ePDF User Manual, #B836C6) |
4 | 840 | 168 | 25-06-2026 | |
RH390 |
Extech Instruments RH390 Manual (Operation & user’s manual), @3XV946 |
6 | 654 | 125 | 15-08-2026 | |
UV510 |
User Manual: Extech Instruments UV510 (4O9HVF, Upd.17-06-2026) |
6 | 589 | 107 | 17-06-2026 | |
RH300 |
Extech Instruments RH300 Guide (Operation & user’s manual), @554L6Q |
8 | 803 | 193 | 19-04-2026 | |
CO100 |
PDF User Guide (@7XER6I), Extech Instruments CO100 Measuring Instruments (17-07-2026) |
3 | 1207 | 278 | 17-07-2026 | |
EC150 |
Guide: Extech Instruments EC150 (58JLM4, Upd.02-07-2026) |
12 | 765 | 131 | 02-07-2026 | |
MA260 |
Extech Instruments Measuring Instruments Operation & user’s manual (File: PDF, 21-06-2026) |
12 | 915 | 147 | 21-06-2026 |