2 Introduction Congratulations on your purchase of the Extech EX520 True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic), Diode Test, and Continuity plus Thermocouple Temperature. It features a rugged design for heavy duty use. Proper use and care of this meter will provide many years of reliable service. Safety This symbol adjacent to anoth
EX520-EU_ENG V2.3 1/08 3 CAUTIONS • Improper use of this meter can cause damage, shock, injury or death. Read and understand this user manual before operating the meter. • Always remove the test leads before replacing the battery or fuses. • Inspect the condition of the test leads and the meter itself for any damage before operating the meter. • Use great care when making measurements if the voltages are greater than 25VAC rms or 35VDC. These vo
EX520-EU_ENG V2.3 1/08 4 SAFETY INSTRUCTIONS This meter has been designed for safe use, but must be operated with caution. The rules listed below must be carefully followed for safe operation. 1. NEVER apply voltage or current to the meter that exceeds the specified maximum: Input Protection Limits Function Maximum Input V DC or V AC 1000VDC/AC rms mA AC/DC 800mA 1000V fast acting fuse A AC/DC 10A 1000V fast acting fuse (20A for 30 seconds max every 15
EX520-EU_ENG V2.3 1/08 5 Controls and Jacks 1. 6,000 count LCD 2. RANGE button 3. Hz and % button 4. Mode button 5. Function switch 6. mA, µA and 10A input jacks 7. COM input jack 8. Positive input jack 9. HOLD and Backlight button 10. RELATIVE button 11. MAX/MIN button Note: Tilt stand and battery compartment are on rear of unit. Symbols and Annunciators Auto power off •))) Continuity Diode test Battery status n nano (10 -9) (capacitance) µ micro
EX520-EU_ENG V2.3 1/08 6 Operating Instructions WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range you have selected. Change to a higher range. DC VOLTAGE MEASUREMENTS CAUTION: Do not measure DC voltages
EX520-EU_ENG V2.3 1/08 7 DC CURRENT MEASUREMENTS CAUTION: Do not make 20A current measurements for longer than 30 seconds. Exceeding 30 seconds may cause damage to the meter and/or the test leads. 1. Insert black test lead banana plug into the negative COM jack. 2. For current measurements up to 6000µA DC, set the function switch to the yellow µA position and insert the red test lead banana plug into the µA/mA jack. 3. For current measurements up to
EX520-EU_ENG V2.3 1/08 8 RESISTANCE MEASUREMENTS WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements. Remove the batteries and unplug the line cords. 1. Set the function switch to the green Ω CAP position. 2. Insert the black test lead banana plug into the negative COM jack. Insert the red test lead banana plug into the positive Ω jack. 3. Press the
EX520-EU_ENG V2.3 1/08 9 TEMPERATURE MEASUREMENTS 1. Set the function switch to the green Temp position. 2. Insert the Temperature Probe into the input jacks, making sure to observe the correct polarity. 3. Press the MODE button to indicate ºF or ºC 4. Touch the Temperature Probe head to the part whose temperature you wish to measure. Keep the probe touching the part under test until the reading stabilizes (about 30 seconds). 5. Read the temperature i
EX520-EU_ENG V2.3 1/08 10 AUTORANGING/MANUAL RANGE SELECTION When the meter is first turned on, it automatically goes into Autoranging. This automatically selects the best range for the measurements being made and is generally the best mode for most measurements. For measurement situations requiring that a range be manually selected, perform the following: 1. Press the RANGE key. The “AUTO” display indicator will turn off. 2.Press the RANGE key to s
EX520-EU_ENG V2.3 1/08 11 Maintenance WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the back cover or the battery or fuse covers. WARNING: To avoid electric shock, do not operate your meter until the battery and fuse covers are in place and fastened securely. This MultiMeter is designed to provide years of dependable service, if the following care instructions are performed: 1. KEEP THE METER DRY
EX520-EU_ENG V2.3 1/08 12 WARNING: To avoid electric shock, do not operate the meter until the battery cover is in place and fastened securely. NOTE: If your meter does not work properly, check the fuses and batteries to make sure that they are still good and that they are properly inserted. REPLACING THE FUSES WARNING: To avoid electric shock, disconnect the test leads from any source of voltage before removing the fuse cover. 1. Disconnect the test le
EX520-EU_ENG V2.3 1/08 13 Specifications Function Range Resolution Accuracy DC Voltage 600mV 0.1mV ±(0.09% reading + 2 digits) 6V 0.001V 60V 0.01V 600V 0.1V 1000V 1V AC Voltage 50 to 60Hz 40Hz to 1KHz 6V 0.001V ±(1.0% reading + 3 dgts) ±(2.0% reading + 3 dgts) 60V 0.01V 600V 0.1V 1000V 1V All AC voltage ranges are specified from 5% of range to 100% of range DC Current 600μA 0.1μA ±(1.0% reading + 3 digits) 6000μA 1μA 60mA 0.01mA 600mA 0.1mA 6A 0
EX520-EU_ENG V2.3 1/08 14 Function Range Resolution Accuracy Resistance 600Ω 0.1Ω ±(0.3% reading + 4 digits) 6kΩ 0.001kΩ 60kΩ 0.01kΩ 600kΩ 0.1kΩ 6MΩ 0.001MΩ 40MΩ 0.01MΩ ±(0.3% reading + 20 digits) Capacitance 60nF 0.01nF ±(3.5% reading + 4 digits) 600nF 0.1nF 6μF 0.001μF 60μF 0.01μF 600μF 0.1μF 1000μF 1μF ±(5% reading + 5 digits) Frequency (electronic) 9.999Hz 0.001Hz ±(0.1% reading + 1 digits) 99.99Hz 0.01Hz 999.9Hz 0.1Hz 9.999
EX520-EU_ENG V2.3 1/08 15 Enclosure Double molded, waterproof (IP67) Shock (Drop Test) 6.5 feet (2 meters) Diode Test Test current of 0.9mA maximum, open circuit voltage 2.8V DC typical Continuity Check Audible signal will sound if the resistance is less than 100Ω (approx.), test current <0.35mA Temperature Sensor Requires type K thermocouple Input Impedance >10MΩ VDC & >10MΩ VAC AC Response True rms ACV Bandwidth 40Hz to 1kHz Crest Factor ≤3 at

Extech Instruments Multimeter Owners Instructions: