Toa DA-500FH CE Operating Instructions Manual
Text of Toa DA-500FH CE Operating Instructions Manual
MULTICHANNEL POWER AMPLIFIERS
DA-550F CE
DA-500FH CE
Thank you for purchasing TOA's Multichannel Power Amplifier.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
Note: The figure shows the DA-550F.
Toa DA-500FH CE TABLE OF CONTENTS
1. SAFETY PRECAUTIONS ............................................................................... 3
2. GENERAL DESCRIPTION ............................................................................. 4
3. FEATURES .......................................................................................................... 4
4. HANDLING PRECAUTIONS .......................................................................... 5
5. INSTALLA
When Installing the Unit
• Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
• Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
• Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close prox
2. GENERAL DESCRIPTION
TOA's DA-550F Multichannel Power Amplifier features high power handling of 550 W x 4 channels (4 Ω
output) or 350 W x 4 channels (8 Ω output) and durability. Besides, its channels 1 and 2, and 3 and 4 are
made available for bridge connection individually, allowing it to be used as a 1,100 W (8 Ω) x 2 channels
stereo amplifier or as a 3-channel amplifier comprised of 1,100 W (8 Ω) + 550 W (4 Ω) x 2 channels.
The DA-500FH Multic
4. HANDLING PRECAUTIONS
• Keep the input cable away from the output cable. If installed close to each other, oscillation could occur.
• To avoid unit failures, never connect outputs of 2 or more units in parallel.
• Only connect speakers with an impedance equal to or greater than those specified. Connecting speakers
with a smaller than specified impedance could cause damage to the unit.
• Periodically clean the filter located inside the ventilati
6. NOMENCLATURE AND FUNCTIONS
[Front]
1. Power switch [ON/OFF]
Power is switched on and off with each depression
of this switch.
2. Power indicator [POWER]
Lights blue when the power is switched on.
3. Input level controls
[CH 1 (BRIDGE 1), CH 2, CH 3 (BRIDGE 2), CH 4]
Adjust the input level of each channel.
4. Ventilation panel (Air Vent)
A filter is located inside the ventilation panel.
To clean the filter, remove the ventilation panel.
(See p. 13; Cle
6. AC inlet
Connect the supplied power cord to this inlet.
The socket-outlet shall be installed near the
equipment and the plug (disconnecting device)
shall be easily accessible.
7. Control/Monitor terminals
[CONTROL/MONITOR]
Connecting external equipment to these terminals
makes the control and monitor functions available
for channels 1 – 4 individually.
(See p.15; How to Use the Control/Mo
Step 1. Switch off the unit's power.
Step 2. Set the BRIDGE ON/OFF switches (DA-550F only) and CH 1 mode ON/OFF switch.
Step 3. Connect the sound source equipment to the Input terminals.
Note: Refer to p. 11 for the removable terminal plug connection.
Step 4. Connect speakers to the Speaker output terminals.
4-1. Unscrew the output terminal cover.
4-2. Strip 10 mm of insulative jacket from the end of the speaker cable,
as shown in the figure at right.
4-
CH 1 mode
ON
ON
ON
Setting
CH1
CH1
CH2
CH3
CH4
BRIDGE 1
BRIDGE 2
Speaker output terminals
8 Ω
8 Ω
-
+
-
+
[1 input - 2 outputs]
CH1
-
+
CH2
-
+
Speaker output terminals
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
OFF
ON
OFF
Setting
4 – 8 Ω
4 – 8 Ω
8 Ω
CH1
CH2
CH3
CH1
CH2
CH3
CH4
BRIDGE 2 -
+
[3 inputs - 3 outputs (1)]
CH3
-
+
CH4
-
+
Speaker output terminals
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
ON
OFF
OFF
Setting
8 Ω
4 – 8 Ω
4
Speaker output terminals
Switch
BRIDGE 1
BRIDGE 2
CH 1 mode
ON
OFF
ON
Setting
8 Ω
4 – 8 Ω
4 – 8 Ω
CH1
CH3
CH4
CH1
CH2
BRIDGE 1
-
+
[1 input - 3 outputs (2)]
CH4
-
+
CH3
-
+
CH2
-
+
CH1
-
+
Speaker output terminals
Switch
CH 1 mode
OFF
Setting
20 Ω
20 Ω
20 Ω
20 Ω
CH1
CH1
CH2
CH2
CH3
CH3
CH4
CH4
[4 inputs - 4 outputs] (factory-preset)
CH4
-
+
CH3
-
+
CH2
-
+
CH1
-
+
Speaker output terminals
Switch
CH 1 mode
ON
Setting
20 Ω
20
Step 1. Loosen the terminal screw, then insert the cable.
Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.)
Tip
Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm in width
Tightens
Loosens
Terminal screw
Slotted screwdriver
Shielded cable
Removable terminal plug
Hot
Cold
Earth
1
1
2
Bit shape 3 mm
8. REMOVABLE TERMINAL PLUG CONNECTION
Cautions
• Be sure to use sh
Toa DA-500FH CE 10. PROTECTION OPERATION LIST
Failure
Protection
Operation Indicator
Remedy
Recovery
Overcurrent due
to overload
Current limiter activated
when impedance drops
below the specified
value.
Peak indicator lights. Remove overload.
Connecting a correct load
automatically restores
normal operation.
Short circuit
Current limiter activated.
Load is disconnected.
Protection indicator
lights.
Check speakers and
lines for short circuit.
Turn off the power switch.
12. CLEANING THE FILTER
Step 1. Switch off the unit's power.
Step 2. Remove the ventilation panel as shown in the figure.
Step 3. Detach the filter inside the ventilation panel.
Step 4. Clear the filter of dust.
Step 5. Replace the filter and ventilation panel.
Detach the panel by pressing
on the right side.
Filter
Ventilation Panel
Ventilation Panel
2
3
13. DIMENSIONAL DIAGRAM
465
442
76.2
88.4
482
371
22.5
404.2
Unit: mm
11. TAMPER-PROOF CAP ATTACHMEN
14. BLOCK DIAGRAMS
14.1. DA-550F
H
C
CH 1 INPUT
E
H
C
CH 2 INPUT
E
Current Limiter
Short Detector
Protection Circuit
OUTPUT 1
relay
CH 1
OUTPUT
CH 2
OUTPUT
+4 dB
-10 dB
CH 1 sensitivity
selection jumper
(+4 dB/-10 dB)
CH 1
input level
control
+4 dB
-10 dB
CH 2 sensitivity
selection jumper
(+4 dB/-10 dB)
CH 2
input level
control
ON
OFF
BRIDGE 1
ON/OFF switch
+
-
BRIDGE 1
OUTPUT
Current Limiter
Short Detector
Protection Circuit
OUTPUT 2
relay
+
-
CH 1 TO
Toa DA-500FH CE 15. HOW TO USE THE CONTROL/MONITOR TERMINALS
The Control/Monitor terminals on the rear panel permit power ON/OFF control of the individual channels and
monitoring for the power ON/OFF status and protection status on each channel, and fan operation status.
Prepare the control panel and status monitor display panel separately referring to the descriptions below.
Notes
• All terminals are electrically isolated from the unit body with the photocouplers.
�
15.3. About Pin 7 of the Control/Monitor Terminals
A ground common to all the control and monitor terminals is assigned to Pin 7.
Both Pins 7 of the Control/Monitor terminal for CH1 and CH2, and that for CH 3 and CH4 are internally
connected to each other.
Pins 7 are isolated from the unit body.
15.5. Connection Cable and Maximum Cable Length
For the connection cable, use a Shielded Category 5 twisted pair cable for LAN (CAT5-STP).
The maximum cable length
Toa DA-500FH CE 15.6. RJ45 Connector's Pin Arrangement and Cable Color Codes
Shielded Category 5 twisted pair cable for LAN
(CAT5-STP)
RJ45 pin No.
To Control/Monitor terminal
1
2
5
6
3
4
7
8
Shield
RJ45 pin No.
Cable color
Cable color
(for T568B)
(for T568A)
Orange/white
Green/white
Orange
Green
Green/white
Orange/white
Blue
Blue
Blue/white
Blue/white
Green
Orange
Brown/white
Brown/white
Brown
Brown
Shield
–
–
8
7
6
5
4
3
2
1
* 0 dB = 0.775 V
Note: The design and specifications are subject to change without notice for improvement.
Power cord (2 m) ................................................................. 1
Removable terminal plug (3 pins) ........................................ 4
Rack mounting screw (with plain washer) 5 x 12 ................ 4
Tamper-proof cap ................................................................ 4
• Accessories
220 – 240 V AC, 50/60