Toa DA-500FH CE Operating Instructions Manual

Text of Toa DA-500FH CE Operating Instructions Manual

MULTICHANNEL POWER AMPLIFIERS

DA-550F CE DA-500FH CE Thank you for purchasing TOA's Multichannel Power Amplifier. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment. Note: The figure shows the DA-550F.

Toa DA-500FH CE TABLE OF CONTENTS

1. SAFETY PRECAUTIONS ............................................................................... 3 2. GENERAL DESCRIPTION ............................................................................. 4 3. FEATURES .......................................................................................................... 4 4. HANDLING PRECAUTIONS .......................................................................... 5 5. INSTALLA

When Installing the Unit

• Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. • Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock. • Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close prox

2. GENERAL DESCRIPTION

TOA's DA-550F Multichannel Power Amplifier features high power handling of 550 W x 4 channels (4 Ω output) or 350 W x 4 channels (8 Ω output) and durability. Besides, its channels 1 and 2, and 3 and 4 are made available for bridge connection individually, allowing it to be used as a 1,100 W (8 Ω) x 2 channels stereo amplifier or as a 3-channel amplifier comprised of 1,100 W (8 Ω) + 550 W (4 Ω) x 2 channels. The DA-500FH Multic

4. HANDLING PRECAUTIONS

• Keep the input cable away from the output cable. If installed close to each other, oscillation could occur. • To avoid unit failures, never connect outputs of 2 or more units in parallel. • Only connect speakers with an impedance equal to or greater than those specified. Connecting speakers with a smaller than specified impedance could cause damage to the unit. • Periodically clean the filter located inside the ventilati

6. NOMENCLATURE AND FUNCTIONS

[Front] 1. Power switch [ON/OFF] Power is switched on and off with each depression of this switch. 2. Power indicator [POWER] Lights blue when the power is switched on. 3. Input level controls [CH 1 (BRIDGE 1), CH 2, CH 3 (BRIDGE 2), CH 4] Adjust the input level of each channel. 4. Ventilation panel (Air Vent) A filter is located inside the ventilation panel. To clean the filter, remove the ventilation panel. (See p. 13; Cle

6. AC inlet

Connect the supplied power cord to this inlet. The socket-outlet shall be installed near the equipment and the plug (disconnecting device) shall be easily accessible. 7. Control/Monitor terminals [CONTROL/MONITOR] Connecting external equipment to these terminals makes the control and monitor functions available for channels 1 – 4 individually. (See p.15; How to Use the Control/Mo

Step 1. Switch off the unit's power.

Step 2. Set the BRIDGE ON/OFF switches (DA-550F only) and CH 1 mode ON/OFF switch. Step 3. Connect the sound source equipment to the Input terminals. Note: Refer to p. 11 for the removable terminal plug connection. Step 4. Connect speakers to the Speaker output terminals. 4-1. Unscrew the output terminal cover. 4-2. Strip 10 mm of insulative jacket from the end of the speaker cable, as shown in the figure at right. 4-

CH 1 mode

ON ON ON Setting CH1 CH1 CH2 CH3 CH4 BRIDGE 1 BRIDGE 2 Speaker output terminals 8 Ω 8 Ω - + - + [1 input - 2 outputs] CH1 - + CH2 - + Speaker output terminals Switch BRIDGE 1 BRIDGE 2 CH 1 mode OFF ON OFF Setting 4 – 8 Ω 4 – 8 Ω 8 Ω CH1 CH2 CH3 CH1 CH2 CH3 CH4 BRIDGE 2 - + [3 inputs - 3 outputs (1)] CH3 - + CH4 - + Speaker output terminals Switch BRIDGE 1 BRIDGE 2 CH 1 mode ON OFF OFF Setting 8 Ω 4 – 8 Ω 4

Speaker output terminals

Switch BRIDGE 1 BRIDGE 2 CH 1 mode ON OFF ON Setting 8 Ω 4 – 8 Ω 4 – 8 Ω CH1 CH3 CH4 CH1 CH2 BRIDGE 1 - + [1 input - 3 outputs (2)] CH4 - + CH3 - + CH2 - + CH1 - + Speaker output terminals Switch CH 1 mode OFF Setting 20 Ω 20 Ω 20 Ω 20 Ω CH1 CH1 CH2 CH2 CH3 CH3 CH4 CH4 [4 inputs - 4 outputs] (factory-preset) CH4 - + CH3 - + CH2 - + CH1 - + Speaker output terminals Switch CH 1 mode ON Setting 20 Ω 20

Step 1. Loosen the terminal screw, then insert the cable.

Step 2. Retighten the terminal screw. (Pull on the cable to ensure it is securely connected.) Tip Recommended slotted screwdriver type: Screwdriver with blade that is 3 mm in width Tightens Loosens Terminal screw Slotted screwdriver Shielded cable Removable terminal plug Hot Cold Earth 1 1 2 Bit shape 3 mm 8. REMOVABLE TERMINAL PLUG CONNECTION Cautions • Be sure to use sh

Toa DA-500FH CE 10. PROTECTION OPERATION LIST

Failure Protection Operation Indicator Remedy Recovery Overcurrent due to overload Current limiter activated when impedance drops below the specified value. Peak indicator lights. Remove overload. Connecting a correct load automatically restores normal operation. Short circuit Current limiter activated. Load is disconnected. Protection indicator lights. Check speakers and lines for short circuit. Turn off the power switch.

12. CLEANING THE FILTER

Step 1. Switch off the unit's power. Step 2. Remove the ventilation panel as shown in the figure. Step 3. Detach the filter inside the ventilation panel. Step 4. Clear the filter of dust. Step 5. Replace the filter and ventilation panel. Detach the panel by pressing on the right side. Filter Ventilation Panel Ventilation Panel 2 3 13. DIMENSIONAL DIAGRAM 465 442 76.2 88.4 482 371 22.5 404.2 Unit: mm 11. TAMPER-PROOF CAP ATTACHMEN

14. BLOCK DIAGRAMS

14.1. DA-550F H C CH 1 INPUT E H C CH 2 INPUT E Current Limiter Short Detector Protection Circuit OUTPUT 1 relay CH 1 OUTPUT CH 2 OUTPUT +4 dB -10 dB CH 1 sensitivity selection jumper (+4 dB/-10 dB) CH 1 input level control +4 dB -10 dB CH 2 sensitivity selection jumper (+4 dB/-10 dB) CH 2 input level control ON OFF BRIDGE 1 ON/OFF switch + - BRIDGE 1 OUTPUT Current Limiter Short Detector Protection Circuit OUTPUT 2 relay + - CH 1 TO

Toa DA-500FH CE 15. HOW TO USE THE CONTROL/MONITOR TERMINALS

The Control/Monitor terminals on the rear panel permit power ON/OFF control of the individual channels and monitoring for the power ON/OFF status and protection status on each channel, and fan operation status. Prepare the control panel and status monitor display panel separately referring to the descriptions below. Notes • All terminals are electrically isolated from the unit body with the photocouplers. �

15.3. About Pin 7 of the Control/Monitor Terminals

A ground common to all the control and monitor terminals is assigned to Pin 7. Both Pins 7 of the Control/Monitor terminal for CH1 and CH2, and that for CH 3 and CH4 are internally connected to each other. Pins 7 are isolated from the unit body. 15.5. Connection Cable and Maximum Cable Length For the connection cable, use a Shielded Category 5 twisted pair cable for LAN (CAT5-STP). The maximum cable length

Toa DA-500FH CE 15.6. RJ45 Connector's Pin Arrangement and Cable Color Codes

Shielded Category 5 twisted pair cable for LAN (CAT5-STP) RJ45 pin No. To Control/Monitor terminal 1 2 5 6 3 4 7 8 Shield RJ45 pin No. Cable color Cable color (for T568B) (for T568A) Orange/white Green/white Orange Green Green/white Orange/white Blue Blue Blue/white Blue/white Green Orange Brown/white Brown/white Brown Brown Shield – – 8 7 6 5 4 3 2 1

* 0 dB = 0.775 V

Note: The design and specifications are subject to change without notice for improvement. Power cord (2 m) ................................................................. 1 Removable terminal plug (3 pins) ........................................ 4 Rack mounting screw (with plain washer) 5 x 12 ................ 4 Tamper-proof cap ................................................................ 4 • Accessories 220 – 240 V AC, 50/60