Field Controls 46259500 Installation Instructions

Text of Field Controls 46259500 Installation Instructions

TM-90R/TM-2000 HUMIDISTAT INSTALLATION INSTRUCTIONS

CAUTION: DISCONNECT THE TM-90R/TM-2000 TRANSFORMER FROM THE RECEPTACLE AND SWITCH "OFF" THE FURNACE ELECTRICAL SUPPLY PRIOR TO INSTALLING THIS HUMIDISTAT. 1. Remove Humidity Control from front side of Base Plate and re- attach to back side of Base Plate. The Adjustment Knob mus

5. Refer to the Wiring Diagram and attach the wires to the

Humidity Control terminals #2 and #3, both Transformer terminals and both TM-90R/TM-2000 terminals, as indicated. The Wiring Diagram shows the proper wire termination required for each connection. CAUTION: All wiring should conform to The National Electrical Code

6. Attach the Foam Mounting Gasket to the Return Air Plenum

around the opening which was previously cut. Secure the Base Plate to the furnace plenum using the two screws supplied. Be sure that the wires are placed through the wiring slot. Do not pull the wires tight. (Figs. 6 & 7) 7. Attach the Cover to the Base Plate, then attach th

NOTE: The Humidistat will allow the electrical current supplied

by the Transformer to flow to the TM-90R/TM-2000 when there the return air plenum humidity drops below the Humidity setting. The TM-90R/TM-2000 "ON/OFF' action is still controlled by the thermal switch which senses warm air flow. The TM-90R/